    Decorative Gas Appliance Installation and Homeowners Operating Instructions PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty . W ARNING: If the in ...

  • Vermont Casting NVC36 - page 2

    2 NVC Series B- V e nt 20000194 T able of Contents Thank you and Congratulations on your purchase of a CFM Corporation fireplace. PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may re ...

  • Vermont Casting NVC36 - page 3

    3 NVC Series B- V e nt 20000194 Installation & Operating Instructions This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Natural Gas and Propane In- stallation Code. If the unit is being installed in a mobile home, the installation should comply with the current C ...

  • Vermont Casting NVC36 - page 4

    4 NVC Series B- V e nt 20000194 A D N M N A B S G H J Gas Line Access - 2" Dia. Gas Line Access 2" Dia. Finished W all Thickness 6" Flue Rough Opening Height Rough Opening Width Rough Opening Depth C Electrical Cable Knock-out - 1" Dia. E L F K P Q R Electrical Box Knock-out - 2" Dia. Electrical Cable Knock-out 1" Dia. ...

  • Vermont Casting NVC36 - page 5

    5 NVC Series B- V e nt 20000194 Clearance to Combustibles Appliances T op .......................................................... 0” (0 mm) Bottom ..................................................... 0” (0 mm) Side ......................................................... 0” (0 mm) Back .................................................... ...

  • Vermont Casting NVC36 - page 6

    6 NVC Series B- V e nt 20000194 Gas Specifications 1. Choose the unit location. 2. Place the unit into position and secure it to the floor with 1 ¹⁄₂ ” (38mm) screws, or nails. The holes to secure the unit to floor are located just behind the access door grille on the left and right side of the unit. 3. Frame in the fireplace with a head ...

  • Vermont Casting NVC36 - page 7

    7 NVC Series B- V e nt 20000194 Gas Line Installation When purging gas line the fornt glass must be removed. Purging gas lines must com- ply with ANSI Z223.1/NFP A 54 in USA and CSA B149.1 in Canada. The gas pipeline can be brought in through the right or left side of the appliance, as well as the bottom. Knock- outs are provided at convenient loca ...

  • Vermont Casting NVC36 - page 8

    8 NVC Series B- V e nt 20000194 The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or , in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code For USA installations follow the local codes and the national electrical code ANSI/NFP A No. 70. It is strongly suggested ...

  • Vermont Casting NVC36 - page 9

    9 NVC Series B- V e nt 20000194 Fig. 9 Firestop/draftstop positions. Ceiling Installation FP384  FIRESTOP 11/21/96 adapted from IGF53 Attic Installation Firestop position when area abov e ceiling is an attic. Firestop position when area abov e ceiling is NOT an attic. (Firestop/draftstop  appearances may  vary. Only 1 firestop  re ...

  • Vermont Casting NVC36 - page 10

    10 NVC Series B- V e nt 20000194 Operating Instructions Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Do not operate appliance with glass front removed, cracked or broken. • Rep ...

  • Vermont Casting NVC36 - page 11

    1 1 NVC Series B- V e nt 20000194 6. Place the top logs onto the locator notches. Ensure that the logs a re secure. (Fig. 12) 7. Place ember material. See "Ember Material Place- ment" section. NVC36 NVC39 NVC43 Front Left Log BB6 BC5 BD6 Front Right Log BB7 BC6 BD7 Rear Log BE5 BC7 BD8 T op Left Log BB9 BC8 BD9 T op Right Log BB10 BC9 BD1 ...

  • Vermont Casting NVC36 - page 12

    12 NVC Series B- V e nt 20000194 T est Chimney Draw A "Chimney Draw" test must be made before the instal- lation is complete. 1. Close all doors and windows in the home and start exhaust fans in the kitchen and bathroom. 2. Light unit and operate for 5 minutes. 3. Hold an ignited match, cigarette, or smoke match in front of the unit. Refe ...

  • Vermont Casting NVC36 - page 13

    13 NVC Series B- V e nt 20000194 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn of f all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONL Y , go on to Step 4. For RN/RP ap ...

  • Vermont Casting NVC36 - page 14

    14 NVC Series B- V e nt 20000194 V ent Safety Switch This fireplace incorporates the use of a V ent Safety Shut-off Switch. The sensor and wiring are factory installed and should not be removed or altered during installation. In the event of total flue blockage the system will detect the increased heat buildup and will automatically shut down the ...

  • Vermont Casting NVC36 - page 15

    15 NVC Series B- V e nt 20000194 T roubleshooting FP649 Turn gas supply off Turn ON/OFF Switch to call for heat. NO NO NO NO NO NO NO Spark across Ignitor Sensor gap Power to module (24V nominal) YES YES YES YES YES YES YES Turn gas on Pilot burner lights? Spark stops when pilot is lit? Main Burner lights? Replace Module START Line Voltage (120VAC) ...

  • Vermont Casting NVC36 - page 16

    16 NVC Series B- V e nt 20000194 Remove glass door before service work Honeywell VS8421 ST ART CHECK Gas Supply On Pilot Lights With Piezo Ignitor • Lockout Has Engaged. Wait 60 Seconds And Try Again. • For Spark At Electrode While Depressing Piezo 1/8" Gap T o Pilot Hood Needed. • All Wiring Connections • Replace Piezo Ignitor • Sup ...

  • Vermont Casting NVC36 - page 17

    17 NVC Series B- V e nt 20000194 T roubleshooting FP396 Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds and Try Again. Piezo Nut Tight for Good Ground. For Spark at Electrode While Depressing Piezo (Red Button) - 1/8" Gap to Pilot Hood Needed. All Wiring Connections Replace Piezo Ignitor ...

  • Vermont Casting NVC36 - page 18

    18 NVC Series B- V e nt 20000194 Cleaning the Standing Pilot Control System The burner and control system consists of • burner tube • gas orifice • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an oc- casional checkup and cleaning and some may require adjustment. If repair is necessary , it s ...

  • Vermont Casting NVC36 - page 19

    19 NVC Series B- V e nt 20000194 FP772A Replacement Parts nvc 8/25/98 31 28 29 26 6a/b 4a/b 5 36 35 34 1a 1b 1c 1d 1e NVC43 Logs 1 27 37 2 3 1a 1b NVC36 1d 1e 1c 1e 1c 1a 1b 1d NVC39 1 18 25 17a/b 22 19                                      ...

  • Vermont Casting NVC36 - page 20

    20 NVC Series B- V e nt 20000194 NVC36/39/43 (continued) Ref. Description NVC36 NVC39 NVC43 6a. Orifice Front Burner-Nat. See Rating Plate 6b. Orifice Front Burner-LP See Rating Plate 7a. Pilot Assy- SIT T op Convertible, LP 10002265 10002265 10002265 7b. Pilot Assy - SIT T op Convertible, Nat. 10002264 10002264 10002264 8a. Orifice Pilot - Nat. ...

  • Vermont Casting NVC36 - page 21

    21 NVC Series B- V e nt 20000194 Optional Accessories Fan Kits FK12 Fan Assembly 1. Open louvre assembly bottom. 2. Install FK12 fan in back of unit between hearth sup- ports. 3. Secure fan on velcro strips. 4. Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connecto ...

  • Vermont Casting NVC36 - page 22

    22 NVC Series B- V e nt 20000194 Remote Controls Optional remote control units are available to control different functions of the appliance. Model Function(s) Controlled MRC1 ON/OFF MRC2 ON/OFF and T emperature MRC3 ON/OFF and T emperature control with a digital and a programmable 24 hour clock IMT Wall mounted thermostat control Ceramic Refractor ...

  • Vermont Casting NVC36 - page 23

    23 NVC Series B- V e nt 20000194 FP1 195 Arched door front 2/27/02 djt FP1 196 Fig. 28 Arched door front in place. EB-1 Electrical Box Standard on electronically controlled models, the EB-1 is also available for other fireplaces. Installation should be completed by a qualified service person. Decorative Frame T rims A selection of decorative f ...

  • Vermont Casting NVC36 - page 24

    24 NVC Series B- V e nt 20000194 ...

  • Vermont Casting NVC36 - page 25

    25 NVC Series B- V e nt 20000194 ...

  • Vermont Casting NVC36 - page 26

    26 NVC Series B- V e nt 20000194 ...

  • Vermont Casting NVC36 - page 27

    27 NVC Series B- V e nt 20000194 BASIC W ARRANTY CFM Corporat ion (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations. EXT ...

  • Vermont Casting NVC36 - page 28

    2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) NVC36RN 29.4 NVC36RP 29.4 NVC36RFN 29.4 NVC36RFP 29.4 NVC36EN 28.5 NVC36EP 28.5 NVC39RN 26.4 NVC39RP 26.4 NVC39RFN 26.4 NVC39RFP 26.4 NVC39EN 25.6 NVC39EP 25.6 NVC43RN ...

Fabricant Vermont Casting Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilVermont Casting NVC36 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vermont Casting
- manuels d’utilisations NVC36
- fiches produit Vermont Casting
- dépliants
- ou étiquettes-énergie Vermont Casting NVC36
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vermont Casting NVC36.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vermont Casting NVC36, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vermont Casting NVC36. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vermont Casting NVC36.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Vermont Casting NVC36, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vermont Casting NVC36 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vermont Casting NVC36.

Le manuel d’utilisation complet Vermont Casting, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vermont Casting NVC36 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vermont Casting NVC36, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVermont Casting NVC36 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vermont Casting NVC36 - qui devraient nous aider dans les premières étapes lors de l'utilisation Vermont Casting NVC36
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vermont Casting NVC36
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vermont Casting NVC36 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vermont Casting NVC36?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vermont Casting NVC36, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vermont Casting NVC36 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)