     The Industrial W orkhorse Model: CIMR-F7Z 2 00V Class 3-phase 0 .4 to 110 kW 400V Class 3-phase 0. 4 to 300 kW     Manual No. I66E-EN-01 Note: Specification s subject to ch ange without notice. Manual No. I66E-EN-01   ? ...

  • Omron Healthcare VARISPEEDF7 - page 2

    F7Z Quic k Star t Guide T ab le of Contents W arnings .............................. .............................. .......... EN-2  Safety Precautions and Inst ructions ..................... ................. ................... .................. EN-3  EMC Compatibility ............ ................ .................... ................. .. ...

  • Omron Healthcare VARISPEEDF7 - page 3

    EN-2 Wa r n i n g s CAUTION Cables m ust not be connected or disconnected, nor signal test s carried out, while the power is switched on. The V arispeed F7 DC bus capacit or remains charged e v en after the p ower has been s witched off . T o av oid an elect ric shock hazard, disco nnect the freq uency inv erter from the mains bef ore carrying out ...

  • Omron Healthcare VARISPEEDF7 - page 4

    EN-3  Safety Precautions and Instructions  General Please read these saf ety precaution s and instructio ns f or use thoroug hly bef ore installing and oper - ating this in v er ter . Also read all of the wa r ning signs on the inv er ter and ensure t hey are n ev er dam- aged or remo ve d. Liv e and hot inv erter components ma y be accessibl ...

  • Omron Healthcare VARISPEEDF7 - page 5

    EN-4  Electrical Connection Carr y out an y work on live equipment in compliance with the nat ional saf ety and accident pre v ention regulations . Carr y out electrical installation in com pliance with the rele v ant regulations . In par ticular , f ollow the installation instructi ons ensur ing electromagnetic compatibility (EMC), e.g. shieldi ...

  • Omron Healthcare VARISPEEDF7 - page 6

    EN-5  Layin g Cables Measures Against Line-Bor ne Inte rf erence: Line filter an d frequency in v er ter must be mounted on t he same metal plat e. Mount t he two compo- nents as close to each other as possib le, with cables kept as shor t a s possible. Use a pow er cabl e with well-groun ded shield. F or motor cab les up to 50 meters in len gth ...

  • Omron Healthcare VARISPEEDF7 - page 7

    EN-6 Installation  Mechanical Installation  Unpac king the In verter Check th e follo wing items after unpac king the in v er ter . If an y irregularities in the abo v e items are f ound, co ntact the agency from wh ich the In verter was pur- chased or y our Omron Y askaw a Motion Control rep resentativ e immediately .  Check ing the Insta ...

  • Omron Healthcare VARISPEEDF7 - page 8

    EN-7  Installation Orientation Install the Inv er ter v er tically so as not to redu ce the cooling effect. When installing the In verter , alwa ys pro vide the f ollowing installatio n space to allow normal heat dissipation. Fig 2 Installation space  Installation of In verters and EMC filter s F or an EMC r ules compliant installation consid ...

  • Omron Healthcare VARISPEEDF7 - page 9

    EN-8  Electrical Connection  Wiring the In verter Fig 4 Wi ring Diagram T T ermin a ting re s i s t a nce P + + - - IG MEMOBU S comm u nic a tion R S -4 8 5/422 P P R+ R- S + S - S hielded wire s Tw i s ted-p a ir s hielded wire s An a log inp u t s etting a dj us tment 2 k Ω 0 to 10 V 2 k Ω 4 to 20 mA P P P u l s e tr a in inp u t [Def au ...

  • Omron Healthcare VARISPEEDF7 - page 10

    EN-9  Main Circuit T erminals Main circui t term inal functions ar e summa rized according to ter minal symbols in Ta b l e 1 . Wire the terminals correctly f or the desired pur poses . T able 1 Main Circuit T er minal Functions (200 V Class and 400 V Class)  Contr ol Circuit T erminals Fig 5 show s the control terminal arrangeme nt. The func ...

  • Omron Healthcare VARISPEEDF7 - page 11

    EN-10 Fig 6 Flywheel Diode Connection Digital output signals M1 During r un (NO) Closed dur ing Run Function selected by H2- 01 to H2-03 Relay contacts Contact capacity: 1 A max. at 250 V AC 1 A max. at 30 VDC *3 M2 M3 Zero speed (NO) Closed when output frequency at zero le vel (b2-01) or below M4 M5 Speed agreement detection (NO) Within ± 2 Hz of ...

  • Omron Healthcare VARISPEEDF7 - page 12

    EN-11  Sinking/Sour cing Mode (NPN/PNP Selection) The input terminal logic can b e switch ed ov er between sinking mode (0-V common, NPN) a nd sourcing mode (+2 4V common, PNP) by usin g the jumper CN5. An e xternal power supp ly is also suppor ted, pro viding more fre edom in signal input methods . T able 3 Sinking / Sourcing Mode and Input Si ...

  • Omron Healthcare VARISPEEDF7 - page 13

    EN-12  Wiring Main Cir cuit Inputs Installing Fuses T o protect th e inv er ter , it is recommended to use semiconductor fuses like the y are sho wn in the tab le below . T able 4 Input Fuse Selection Consider the f ollowing precautions f or the main circuit power supply input. • If a moulded ca se circuit break er is used f or th e power sup ...

  • Omron Healthcare VARISPEEDF7 - page 14

    EN-13 • If an ear th leakage br eaker is used, it should be able to detect all kinds of current in o rder to ensure a saf e ear th leakage curr ent detection • A magnetic contactor or other s witching de vice can be u sed at the in verter input. The in verter should not be po wered up more th an once per hour . • The input phases (R /S/T) can ...

  • Omron Healthcare VARISPEEDF7 - page 15

    EN-14 K e ypad Operation  Digital Operator Displa y (optional) The key names and function s of the Digital Operator are descr ibed below  Digital Operator K eys Key Name Function LOCAL/REMOTE K e y Switches between operation via th e Digital Operator (LOCAL ) and the settings in b 1-01 and b1-02 (REMOTE). This ke y can be enabled or disabled ...

  • Omron Healthcare VARISPEEDF7 - page 16

    EN-15 P o wer Up and Basic P arameter Setup  Star t Up Pr ocedure Fig 8 T r ial Operation Flowchart YE S * 6 * 6 * 4 Motor oper a tion po ss i b le d u ring au tot u ning? *3 S etting s a ccording to control mode S TA R T In s t a ll a tion Wiring S et power su pply vol t a ge j u mper * 1 Confirm s t a t us T u r n ON power B as ic s etting s ( ...

  • Omron Healthcare VARISPEEDF7 - page 17

    EN-16  Bef ore P ower Up The f ollowing poi nts should be chec ked carefully bef ore the power is s witched on. • Chec k if the power supply meets the inv er ter specification. • Chec k if the pow er supply cable s are tightly connected to th e right ter minals (L1, L2, L3) . • Chec k if the motor cab les are tightl y connected to the righ ...

  • Omron Healthcare VARISPEEDF7 - page 18

    EN-17 motor parameters will be set automati cally . The rema ining motor parameters will be set automati- cally during the first t ime operation. Non-r otating A utotuning f or Line-to-Line Resistance ( T1-01 = 2) Non-rotati ng autotuning for line-to-line re sistance can be u sed in any control mode. This is the only possible autotuning for V/f con ...

  • Omron Healthcare VARISPEEDF7 - page 19

    EN-18 Pa ra m - eter Num- ber Name Description Initialize Data A1-00 Language selection f or Digital Opera- tor dis- play(JV OP- 160-O Y only) 0: English 2: German 3: French 4: Italian 5: Spanish 6: P ortuguese A1-01 Pa r am e t e r access level 0: Monitoring only (M onitoring drive mode and settin g A1-01 and A1-04.) 1: Used to se lect user par am ...

  • Omron Healthcare VARISPEEDF7 - page 20

    EN-19 E1-04 Max. output frequency (FMAX) T o set V/f characteristics in a straight line, set the same v alues for E1-07 and E1-09. In this case, the setting for E1-08 will be disregarded. Alwa ys ensure that the four frequen- cies are set in the follo wing order : E1-04 (FMAX) ≥ E1-06 (F A) > E1-07 (FB) ≥ E1-09 (FMIN) E1-05 Max. output volta ...

  • Omron Healthcare VARISPEEDF7 - page 21

    EN-20 T orque Limit (only OL V an d CL V) L7-01 Forw ard drive torque limit Sets the torque limit vlaue as a per- centage of the motor rated torque. Four individual regions can be set. L7-02 Rev erse drive torque limit L7-03 F orward regenerative torque limit L7-04 Rev erse regenerativ torque limit Monitor Data U1-01 F requency ref erence in Hz / r ...

  • Omron Healthcare VARISPEEDF7 - page 22

    EN-21 T r oubleshooting  General F aults and Alarms F aults and Alarms indicate unsusa l inv er ter / application conditi ons. An alarm does not necessarily switch off t he inv er ter b ut a message is displa yed on th e ke ypad (i.e. a flashing alarm code) and an alarm output can be ge nerated at th e multi-functio n outputs (H2-01 and H2-02) i ...

  • Omron Healthcare VARISPEEDF7 - page 23

    EN-22 OC Over Current  Over Current The Inv er ter’ s output current e xceeded the over- current detection lev el. • Remove the motor and run the Inverter without the motor . • Check the motor for a phase-to-phase shor t. • V erify the accel/decel times (C1-  ). • C hec k the Inverter for a phase-to-phase shor t at the output. OH ...

  • Omron Healthcare VARISPEEDF7 - page 24

    EN-23  Operator Pr ogramming Error s An Operator Programming Error (OPE) occurs when two or more p arameter related to each other are set inapprop riately or an individual parameter setting is incorrect. The In v er ter does not operate until the parameter setting is corrected; howe v er , no other alarm or fault output will occur . If an OPE oc ...

  • Omron Healthcare VARISPEEDF7 - page 25

    EN-24  A utotuning F aults A utotuning f aults are sho wn below . When the f ollowin g fa ults are detected, t he fa ult is displa yed on the digital operator and the motor coasts to st op. No f ault or alarm outputs will be operated. OPE08 Constant Selection Function Selection Error A setting has been made that is applicable with the cur- rent ...

Fabricant Omron Healthcare Catégorie Printer

Les documents que nous recevons du fabricant de l'appareilOmron Healthcare VARISPEEDF7 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omron Healthcare
- manuels d’utilisations VARISPEEDF7
- fiches produit Omron Healthcare
- dépliants
- ou étiquettes-énergie Omron Healthcare VARISPEEDF7
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omron Healthcare VARISPEEDF7.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omron Healthcare VARISPEEDF7, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omron Healthcare VARISPEEDF7. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omron Healthcare VARISPEEDF7.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Omron Healthcare VARISPEEDF7, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omron Healthcare VARISPEEDF7 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omron Healthcare VARISPEEDF7.

Le manuel d’utilisation complet Omron Healthcare, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omron Healthcare VARISPEEDF7 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omron Healthcare VARISPEEDF7, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmron Healthcare VARISPEEDF7 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omron Healthcare VARISPEEDF7 - qui devraient nous aider dans les premières étapes lors de l'utilisation Omron Healthcare VARISPEEDF7
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omron Healthcare VARISPEEDF7
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omron Healthcare VARISPEEDF7 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omron Healthcare VARISPEEDF7?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omron Healthcare VARISPEEDF7, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omron Healthcare VARISPEEDF7 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)