    RANGER ™ 10,000 OPERA TOR’S MANUAL For Machines with Code Number 11041, 11095, 11151, 11253 IM819-B September, 2006 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT IN ...

  • Lincoln Electric IM819-B - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric IM819-B - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric IM819-B - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric IM819-B - page 5

    Mar. ‘93 iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les ...

  • Lincoln Electric IM819-B - page 6

    v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay ...

  • Lincoln Electric IM819-B - page 7

    vi vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications .......................................................................................................A-1 Safety Precautions .......................... ...

  • Lincoln Electric IM819-B - page 8

    A-1 INST ALLA TION RANGER 10,000 A-1 TECHNICAL SPECIFICA TIONS - Ranger 10,000 (K1419-4 ), (K2160-3 ) and (K2468-1) INPUT - GASOLINE ENGINE RA TED OUTPUT @ 104°F (40°C)- WELDER HEIGHT WIDTH DEPTH WEIGHT 30.3 in. 19.1 in. 42.0 in. 502 lbs. (228kg) K1419-4 770 mm 485 mm 1067 mm 505 lbs. (229kg) K2160-3 528 lbs. (240kg) K2468-1 RA TED OUTPUT @ 104° ...

  • Lincoln Electric IM819-B - page 9

    A-2 INST ALLA TION RANGER 10,000 A-2 SAFETY PRECAUTIONS MACHINE GROUNDING Because this portable engine driven welder or genera- tor creates it’s own power, it is not necessary to con- nect it’s frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.). To prevent dangerous electric shock, other equip- ...

  • Lincoln Electric IM819-B - page 10

    FUEL Fill the fuel tank with clean, fresh, lead-free gasoline. Observe fuel gauge while filling to prevent overfilling. OIL The Ranger 10,000 is shipped with the engine crankcase filled with SAE 10W-30 oil. Check the oil level before starting the engine. If it is not up to the full mark on the dip stick, add oil as required. Make cer- tain that the ...

  • Lincoln Electric IM819-B - page 11

    A-4 INST ALLA TION RANGER 10,000 A-4 WELDING OUTPUT CABLES With the engine off, connect the electrode and work cables to the studs provided. These connections should be checked periodically and tightened if neces- sary. Loose connections will result in overheating of the output studs. When welding at a considerable distance from the welder, be sure ...

  • Lincoln Electric IM819-B - page 12

    A-5 INST ALLA TION RANGER 10,000 A-5 LOCA TION / VENTILA TION The welder should be located to provide an unrestrict- ed flow of clean, cool air to the cooling air inlets and to avoid heated air coming out of the welder recirculating back to the cooling air inlet. Also, locate the welder so that engine exhaust fumes are properly vented to an outside ...

  • Lincoln Electric IM819-B - page 13

    A-6 INST ALLA TION RANGER 10,000 A-6 120 V DUPLEX RECEPTACLES The 120V auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs. The current rating of any plug used with the system must be at least equal to the current load through the associated receptacle. MOTOR STA ...

  • Lincoln Electric IM819-B - page 14

    A-7 INST ALLA TION RANGER 10,000 A-7 TABLE lll ELECTRICAL DEVICE USE WITH THE RANGER 10,000. Type Common Electrical Devices Possible Concerns Resistive Heaters, toasters, incandescent NONE light bulbs, electric range, hot pan, skillet, coffee maker. Capacitive TV sets, radios, microwaves, Voltage spikes or high voltage appliances with electrical co ...

  • Lincoln Electric IM819-B - page 15

    A-8 INST ALLA TION RANGER 10,000 A-8 STANDBY POWER CONNECTIONS The RANGER 10,000 is suitable for temporary, stand- by, or emergency power using the engine manufactur- er ’ s recommended maintenance schedule. The RANGER 10,000 can be permanently installed as a standby power unit for 240V-3 wire, single phase 38 ampere service. (Connections must be ...

  • Lincoln Electric IM819-B - page 16

    240 Volt 60 Hz. 3-Wire Service POWER COMPANY METER 240 VOLT 120 VOLT 120 VOLT LOAD N NEUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERCURRENT PROTECTION GND N NOTE: No. 6 COPPER CONDUCTOR CABLE SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE SIZE RECOMMENDATIONS. 240 VOLT GROUNDED CONDUCTOR 40 AMP 240 VOLT DOUBLE POLE CIRCUIT BREAKER DOUBLE P ...

  • Lincoln Electric IM819-B - page 17

    WELDER CONTROLS - FUNCTION AND OPERA TION ENGINE SWITCH The engine switch is used to Start the Engine, Select High Idle or Auto Idle while the engine is running, and stop the Engine. When placed in the “ OFF ” position, the ignition circuit is de-energized to shut down the engine. When held in the “ START ” position, the engine starter moto ...

  • Lincoln Electric IM819-B - page 18

    “ RANGE ” SWITCH The “ Range ” switch is used to select one of three amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range. Never change the “ RANGE ” Switch setting while welding. This will damage the switch. ------------------------------------------------------------------------ “ CONTROL ” D ...

  • Lincoln Electric IM819-B - page 19

    B-3 OPERA TION B-3 ST ARTING/SHUTDOWN INSTRUCTIONS STARTING THE ENGINE Be sure all Pre-Operation Maintenance has been per- formed. Also, read the Engine Owner ’ s Manual before starting for the first time. Remove all loads connected to the AC power recepta- cles. Use the choke control as follows: KOHLER ENGINE - Always pull the choke control out ...

  • Lincoln Electric IM819-B - page 20

    B-4 OPERA TION B-4 WELDING PROCESS For any electrodes the procedures should be kept within the rating of the machine. For electrode infor- mation see the appropriate Lincoln publication. STICK (CONSTANT CURRENT) WELDING Connect welding cables to the "TO WORK ” and "ELECTRODE ” studs. Start the engine. Set the "Polarity ” switch ...

  • Lincoln Electric IM819-B - page 21

    B-5 OPERA TION B-5 RANGER 10,000 SUMMARY OF WELDING PROCESSES CONTROL ELECTRODE CABLE IDLE WHEN NOT TO START PROCESS USED MODE WELDING WELDING STICK No AUTO Hot Touch electrode to work. Welding starts immediately and engine goes to high idle. WIRE FEED, LN-25 WITH No AUTO Cold Press gun trigger, LN-25 INTERNAL CONTACTOR contactor closes. Welding st ...

  • Lincoln Electric IM819-B - page 22

    C-1 ACCESSORIES C-1 RANGER 10,000 OPTIONAL EQUIPMENT (Field Installed) K957-1 HEAVY DUTY, TWO WHEEL TRAILER FOR SMALL WELDERS - For road, off-road and in-plant and yard towing. (For highway use, consult applicable federal, state and local laws regarding requirements for brakes, lights, fenders, etc.) Order K957-1 Trailer K958-1 Ball Hitch K958-2 Lu ...

  • Lincoln Electric IM819-B - page 23

    C-2 ACCESSORIES C-2 RANGER 10,000 RECOMMENDED EQUIPMENT STICK K704 Accessory Kit - For Stick Welding. Includes 35 ft (10.7m). • 2/0 AWG electrode cable, 30 ft. (9.1m) • 2/0 AWG work cable with lugs, headshield, filter plate, work clamp, and electrode holder. 400 amp capacity. K875 Accessory Kit - For stick welding. Includes 20 Ft. (6.1m). #6 el ...

  • Lincoln Electric IM819-B - page 24

    Have qualified personnel do the maintenance work. Turn the engine off before working inside the machine. In some cases, it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the mainte- nance requiring their removal is complete. Always use the greatest care when working ...

  • Lincoln Electric IM819-B - page 25

    D-2 MAINTENANCE D-2 Use 4-stroke motor oil that meets or exceeds the requirements for API service classification SG or SH. Always check the API SERVICE label on the oil con- tainer to be sure it includes the letters SG or SH. SAE 10W-30 is recommended for general, all-tempera- ture use, -5 F to 104 F (-20 C to 40 C). See Engine Owner ’ s Manual f ...

  • Lincoln Electric IM819-B - page 26

    D-3 MAINTENANCE D-3 ENGINE ADJUSTMENTS OVERSPEED IS HAZARDOUS The maximum allowable high idle speed for this machine is 3750 RPM, no load. Do NOT tamper with governor components or setting or make any other adjustments to increase the maximum speed. Severe personal injury and damage to the machine can result if operated at speeds above maximum. --- ...

  • Lincoln Electric IM819-B - page 27

    E-1 TROUBLESHOOTING E-1 RANGER 10,000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repair po ...

  • Lincoln Electric IM819-B - page 28

    E-2 TROUBLESHOOTING E-2 RANGER 10,000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ...

  • Lincoln Electric IM819-B - page 29

    E-3 TROUBLESHOOTING E-3 RANGER 10,000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ...

  • Lincoln Electric IM819-B - page 30

    STARTER CR1 STARTER SOLENOID 12 VOLT IDLER SOLENOID BATTERY AC AC B+ SWITCH REGULATOR FLYWHEEL ALTERNATO R B- HOUR METER 5E 5D 224 ENGINE COMPONENTS 224A 1 2 3 CONNECTOR PIN NU MBERS: 7 6 12 1 2 3 4 J1 N.A. B J2 SOLENOID FUEL SHUTOFF OIL PRESSURE TERMINAL BLOCK (SEE CONN.) 209A 209A 224C 210 B B GENERATOR LEAD END (NOTE CAVITY NUMBERS) LOCATING TAB ...

  • Lincoln Electric IM819-B - page 31

    F-2 DIAGRAMS F-2 RANGER 10,000 IDLER SOLENOID HOUR METER 5E 5D 224 1 2 3 CONNECTOR PIN NU MBERS: 7 6 12 1 2 3 4 J1 J2 209A M20301 215 + ELECTRIC AL SYMBOL S PER E1537 STATOR REACTOR S1 WO RK ELECTRODE CHOKE D1 S2 ROTOR PCB1 SLIP RING NEAREST LAMINATION W1 W2 C1 S1 R1 R5 C1 L1 - + + R3 STATOR REACTOR + 10 8 1 7 12 6 6 5 3 9 7 200A 219 3 ENGINE CROSS ...

  • Lincoln Electric IM819-B - page 32

    F-3 DIAGRAMS F-3 RANGER 10,000 CR1 STARTER SOLENOID AC AC B+ REGULATOR FLYWHEEL ALTERNATOR B- 5E 5D 224 ENGINE COMPONENTS 224A 1 2 3 CONNECTOR PIN NUMBERS: 7 6 12 1 2 3 4 J1 J2 209A 209A 224C 210 GENERATOR LEAD END (NOTE CAVITY NUMBERS) LOCATING TAB TERMINAL BLOCK CONNECTION 208 208 (CAVITY #2) 211 (CAVITY #3) 224C (CAVITY #4) 1 3 2 4 211 C M20431 ...

  • Lincoln Electric IM819-B - page 33

    F-4 DIAGRAMS F-4 RANGER 10,000 RANGER 10,000 RANGER 10,000 / / L L N -15 AND LN-25 ACROSS T AND LN-25 ACROSS T H E ARC CONNECT E ARC CONNECT IO N DI N DI AG RA M ELECTRIC SHOCK can kill Do not operate with panels open. Disconnect NEGATIVE (-) Battery lead before servicing. Do not touch elec trical ly live parts. W ARN ING MOVING PARTS can injure Ke ...

  • Lincoln Electric IM819-B - page 34

    F-5 DIAGRAMS F-5 RANGER 10,000 M2 02 67 A. A. 0 1 26.5 9 30.2 7 9.09 9.09 17.0 0 21.2 2 8.80 30.0 0 42.0 0 22.1 5 10.3 3 CE NTER OF GR AVITY WITH O IL IN ENG INE AN D FULL FU EL T AN K 9.31 CE NTERLI NE OF SH AFT 9.59 10.1 9 OIL FILTER REM OVAL KOHLER , HONDA AND ROBIN / SUBARU KOHLER , HONDA AND ROBIN / SUBARU ...

  • Lincoln Electric IM819-B - page 35

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE PARA EL ...

  • Lincoln Electric IM819-B - page 36

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes f ...

  • Lincoln Electric IM819-B - page 37

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabricant Lincoln Electric Catégorie Welding System

Les documents que nous recevons du fabricant de l'appareilLincoln Electric IM819-B peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lincoln Electric
- manuels d’utilisations IM819-B
- fiches produit Lincoln Electric
- dépliants
- ou étiquettes-énergie Lincoln Electric IM819-B
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lincoln Electric IM819-B.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lincoln Electric IM819-B, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lincoln Electric IM819-B. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lincoln Electric IM819-B.

Manuel d’utilisation complet de l’appareil Lincoln Electric IM819-B, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lincoln Electric IM819-B par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lincoln Electric IM819-B.

Le manuel d’utilisation complet Lincoln Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lincoln Electric IM819-B - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lincoln Electric IM819-B, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLincoln Electric IM819-B qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lincoln Electric IM819-B - qui devraient nous aider dans les premières étapes lors de l'utilisation Lincoln Electric IM819-B
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lincoln Electric IM819-B
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lincoln Electric IM819-B dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lincoln Electric IM819-B?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lincoln Electric IM819-B, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lincoln Electric IM819-B il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)