    701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com HOBART HGF, HGD AND HGC SERIES GAS FRYERS WITH OR WITHOUT FILTER-IN-A-DRAWER MODELS HGF35 ML-126994 HGF45 ML-126995 HGF65 ML-126996 HGF85 ML-126997 HGFD35 ML-126416 HGFD45 ML-126417 HGFD65 ML-126418 HGFD85 ML-126419 HGFC35 ML-126420 HGFC45 ML-126421 HGFC65 ML-126422 HGFC85 ML ...

  • Hobart HGF85F ML-135539 - page 2

    – 2 – IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBT ...

  • Hobart HGF85F ML-135539 - page 3

    – 3 – No. Model Size Tu be s BTU/Hr. Width Lbs. of Fry Compound 3 5 3 90,000 15 1/2" (39 cm) 35-40 (16-18 kg) 4 5 4 120,000 15 1/2" (39 cm) 45-50 (20-23 kg) 6 5 5 150,000 21" (53 cm) 65-75 (29-34 kg) 8 5 5 150,000 21" (53 cm) 85-90 (39-41 kg) Installation, Operation and Care of MODELS HGF, HGD and HGC SERIES GAS FRYERS SAVE ...

  • Hobart HGF85F ML-135539 - page 4

    – 4 – INSTALLATION Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel. Ensure the fryer is configured for the proper elevation. UNPACKING This fryer was carefully inspected before leaving the factory. The transport ...

  • Hobart HGF85F ML-135539 - page 5

    – 5 – ASSEMBLY When installed, the fryer must be restrained to prevent tipping to avoid the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances or installing the fryer in an alcove, or by separate means, such as adequate ties. Fryers Mounted on Legs (Non-Batteried Frye ...

  • Hobart HGF85F ML-135539 - page 6

    – 6 – GAS CONNECTIONS CAUTION: All gas supply connections and any pipe joint compound must be resistant to the reaction of propane gases. The gas inlet is located on the lower right rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer. The gas supply line must be at least the equivalent of 1 ...

  • Hobart HGF85F ML-135539 - page 7

    – 7 – FLUE CONNECTIONS The fryer must be located under a hood with adequate connection to an exhaust duct. The hood must extend 6" (15 cm) beyond fryer sides. Adequate ventilation must be provided and comply with Vapor Removal from Cooking Equipment, ANSI-NFPA Standard #96 (latest edition), available from the National Fire Protection Assoc ...

  • Hobart HGF85F ML-135539 - page 8

    – 8 – OPERA TION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK. BEFORE FIRST USE • Clean the protective metal oils from all surface parts and the tank inter ...

  • Hobart HGF85F ML-135539 - page 9

    – 9 – LIGHTING INSTRUCTIONS FOR HGF FRYER WITH MANUAL PILOT IGNITION CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. 1 . Turn thermostat OFF. Thermostat is located behind the door (Fig. 5). 2 . Turn gas control valve knob to PILOT (Fig. 6). Wait 5 minutes for unburned gas to vent. NOTE: PILO ...

  • Hobart HGF85F ML-135539 - page 10

    – 10 – HGFD & HGFC FRYER CONTROLS Gas Valve Extension Arm - Used to ignite and operate the pilot. LIGHTING INSTRUCTIONS FOR MANUAL PILOT IGNITION (HGFD & HGFC SERIES) CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. 1 . Push the gas valve extension arm in and turn arm to OFF. Wait 5 m ...

  • Hobart HGF85F ML-135539 - page 11

    – 11 – STARTUP WITH ELECTRONIC IGNITION (HGFD & HGFC SERIES) CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. 1 . Plug the power cord into an appropriate grounded receptacle. 2 . Turn the main gas valve on. 3 . Fill the fry tank with shortening (Refer to Melt Control Options). 4 . Open fr ...

  • Hobart HGF85F ML-135539 - page 12

    – 12 – HGFD SERIES CONTROLS HGFD Series Fryers are equipped with digital controls and a solid state thermostat. Control Guide UP NOTE: For cleaning purposes when the fryer is filled with water. Temperature is automatically maintained at approximately 192°F (89°C). CONTROL DESCRIPTION Power switch; for turning the fryer on or off.(Power switch ...

  • Hobart HGF85F ML-135539 - page 13

    – 13 – PROGRAMMING Temperature, time, energy source and other parameters must be set before operating. Once these parameters are set, the fryer can be operated at the touch of a button. Press to enter the program mode and scroll through the parameters. If the Parameter Lock feature is on, LoC is displayed in the window and program entry cannot ...

  • Hobart HGF85F ML-135539 - page 14

    – 14 – USING THE FRYER (After Startup) Models Without Basket Lift Option 1 . Load the fry basket(s); do not overfill. See Recommended Basket Capacities section in this manual. 2 . Carefully lower basket(s) into shortening. 3 . Press to start the right timer. 4 . When the timer times out, display will blink "L" in the lower right corne ...

  • Hobart HGF85F ML-135539 - page 15

    – 15 – When the timer times out, a beeper sounds and the basket(s) automatically raise. Press to silence the left timer beeper. Press to silence the right timer beeper. 4 . For Single Basket Lifts: Press to lower the right basket. The timer begins counting down. When the timer times out, a beeper sounds and the basket automatically raises. Pres ...

  • Hobart HGF85F ML-135539 - page 16

    – 16 – HGFC SERIES CONTROLS HGFC Series Fryers have a microprocessor (computer) thermostat and timer. Control Guide Initiates program cooking cycles for units with or without basketlifts. For turning on or off the filter pump when supplied with built in filtering system. NOTE: For cleaning purposes when the fryer is filled with water. Temperatu ...

  • Hobart HGF85F ML-135539 - page 17

    – 17 – PARAMETER STEPS LEFT DISPLAY RIGHT DISPLAY Press SELECT OPTIONS Press DEGREES F or C F or C Press to select Fahrenheit or Celsius. DEGREES F or C F or C Press when complete. PROGRAM Press SELECT OPTIONS Press SET PASS NEW PASS Press to select NO PASS. NO PASS NEW PASS Press when complete. PROGRAM Press SELECT OPTIONS Press SET PASS NEW P ...

  • Hobart HGF85F ML-135539 - page 18

    – 18 – Programming Guide (cont.) *Recovery - During a cold start, the controller measures the time the fryer takes to heat from 200°F to 250°F (93°C to 121°C) and compares it with factory default values. PARAMETER STEPS LEFT DISPLAY RIGHT DISPLAY Press SELECT OPTIONS Press ENGLISH (Factory Default) LANGUAGE Press to select a language. ENGLI ...

  • Hobart HGF85F ML-135539 - page 19

    – 19 – Melt Options When using solid shortening in the fryer, the SOLID melt option must be used. Solid shortening must be gently warmed to a liquid state before heating to frying temperatures. Melting solid shortening without using this option will damage the fry tank and scorch the shortening. The controller has three options for bring shorte ...

  • Hobart HGF85F ML-135539 - page 20

    – 20 – TEMPERATURE AND TIME PROGRAMMING Temperature 1 . Press to enter program mode. PROGRAM is displayed in the window. 2 . Press to enter temperature mode. 000°F and TEMP are displayed in the window. 3 . Press through to enter desired fry temperature. The fry temperature is displayed in the window. 4 . Press to exit the temperature mode. Pre ...

  • Hobart HGF85F ML-135539 - page 21

    – 21 – Timers through : 1 . Press and enter the program mode. PROGRAM is displayed in the window. 2 . Press . The LED's on timers through are lit and SELECT PRODUCT is displayed in the window. 3. To select a timer, press one of the lit timer numbers; CK# 00:00 and TIME are displayed in the window. 4 . Enter the desired time using keys thro ...

  • Hobart HGF85F ML-135539 - page 22

    – 22 – Setting Advanced Time Features 1 . Press and enter the program mode. 2 . Press for timers through , or press for timers through . The LEDs are lit on the timers available for programming, and SELECT PRODUCT is displayed in the window. 3 . Select a timer; the programmed time is displayed in the window. A. Duty Time : 1) Press either arrow ...

  • Hobart HGF85F ML-135539 - page 23

    – 23 – Time Programming Quick Chart Press to enter the program mode Press for timers to Press for timers to Select a Timer Press to continue Set HOLD Time Select COMP or STRAIGHT Press Press Set DUTY Time Press Exit Program Enter Time Using to ...

  • Hobart HGF85F ML-135539 - page 24

    – 24 – USING THE FRYER (After Startup) Models Without Basket Lift Option 1 . Load the fry basket(s); do not overfill. See Recommended Basket Capacities section in this manual. 2 . Carefully lower basket(s) into shortening. 3 . Press the desired program number to select the product to be timed. Timers through are programmed for products. Once th ...

  • Hobart HGF85F ML-135539 - page 25

    – 25 – FRYING GUIDELINES (ALL MODELS) • Heat shortening to set temperature. • High Limit Device (All Models) - If the shortening becomes overheated, a high-temperature device will close the gas valve and extinguish the pilot. Should this occur, the pilot will be unable to relight until the shortening temperature is below 300°F (149°C). If ...

  • Hobart HGF85F ML-135539 - page 26

    – 26 – DAILY FILTERING WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. Filtering Guidelines (All Models) • Stand alone fryers are available in filter-ready and non-filter-ready versions. • Battery interplumbing is available only on fryers equipped with Filter-In-A-Drawer. • A cold fry ...

  • Hobart HGF85F ML-135539 - page 27

    – 27 – Battery Interplumbing (Available Only on Filter-In-A-Drawer Models) A battery of fryers equipped with optional interplumbing connects the fry tanks to a common drain. Each tank has an individual drain valve. Only one tank can be filtered at a time. Instructions for the Filter-In- A-Drawer are covered in a separate manual. Follow the inst ...

  • Hobart HGF85F ML-135539 - page 28

    – 28 – CLEANING WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. DAILY • Clean all exterior surfaces of your fryer at least once daily. • Use a damp cloth with warm water and a mild soap or detergent. • Rinse thoroughly, then polish with a soft, dry cloth. • Keep the fryer exterior c ...

  • Hobart HGF85F ML-135539 - page 29

    – 29 – 10. Drain the tank. 11. Rinse the tank thoroughly with clear, hot water (all traces of cleaner must be removed). 12. Dry the tank thoroughly. 13. Close the drain valve and add shortening. 14. Shortening level should be between the MIN and MAX lines. Shortening will expand when heated; do not fill the fry tank past the MAX line. The fryer ...

  • Hobart HGF85F ML-135539 - page 30

    – 30 – TROUBLESHOOTING GUIDE SYMPTOM No power when switch is turned on. Fryer will not heat. Fryer continues to heat. Fryer heats, but will not reach desired temperature. Fryer stops heating during operation. POSSIBLE CAUSES / SOLUTIONS Tripped breaker; fuse blown / Verify fryer is plugged in and outlet has power. Check power cord connection at ...

  • Hobart HGF85F ML-135539 - page 31

    – 31 – ALARMS AND ERROR MESSAGES (HGD and HGC Series) Pilot Out - If the pilot is out, the control displays the following message: (Electronic ignition only) HGD Series - FIrE OUt HGC Series - PILOT OUT If no action is taken after 90 seconds, an alarm sounds continuously, the heat demand is disabled and any running cooking cycles are cancelled ...

  • Hobart HGF85F ML-135539 - page 32

    – 32 – FORM 35643 Rev. A (Apr. 2005) PRINTED IN U.S.A. NOTES ...

Fabricant Hobart Catégorie Fryer

Les documents que nous recevons du fabricant de l'appareilHobart HGF85F ML-135539 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Hobart
- manuels d’utilisations HGF85F ML-135539
- fiches produit Hobart
- dépliants
- ou étiquettes-énergie Hobart HGF85F ML-135539
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Hobart HGF85F ML-135539.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Hobart HGF85F ML-135539, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Hobart HGF85F ML-135539. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Hobart HGF85F ML-135539.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Hobart HGF85F ML-135539, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Hobart HGF85F ML-135539 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Hobart HGF85F ML-135539.

Le manuel d’utilisation complet Hobart, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Hobart HGF85F ML-135539 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Hobart HGF85F ML-135539, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHobart HGF85F ML-135539 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Hobart HGF85F ML-135539 - qui devraient nous aider dans les premières étapes lors de l'utilisation Hobart HGF85F ML-135539
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Hobart HGF85F ML-135539
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Hobart HGF85F ML-135539 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Hobart HGF85F ML-135539?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Hobart HGF85F ML-135539, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Hobart HGF85F ML-135539 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)