Manuale per l’uso Cabletron Systems 6000

58 pagine 0.66 mb
Scarica

Vai alla pagina of 58

Summary
  • Cabletron Systems 6000 - page 1

    ETHERNET 6E233-49 24 48 37 36 25 24 1 12 5 9 67 8 10 11 12 1234 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 13 RESET COM CPU Title Page 6E233-49 Smar tSwitc h 6000 Interface Module User’ s Guide 9033379 ...

  • Cabletron Systems 6000 - page 2

    ...

  • Cabletron Systems 6000 - page 3

    i NOTICE Cabletron Systems reserves t he right to make changes in specificati ons and ot her informati on contained in this d ocument without prio r notice. The reader should in a ll cases con sult Cable tron Sy stems to de termine wheth er any such ch anges have been m ade. The hardw are, f irmw are, or software d escribed in t his manua l is subj ...

  • Cabletron Systems 6000 - page 4

    ii FCC NOTICE This de v ic e co mplies with P art 15 of the FCC rules. Operat ion is sub ject to th e follo wing two condit ion s: (1) t h is de vice may not cause harmful in terference, and (2 ) this device mus t accept any interfe rence received, including interference th at may ca u se undesir e d op e r at ion. NO TE : This equipment has b een ...

  • Cabletron Systems 6000 - page 5

    iii CABLETRON SYSTEMS, INC. PROGRAM LICENSE AGREEMENT IMPORTANT: THIS LICENSE APPLIES FOR USE OF PRODUCT IN THE FOLLOWING GEOGRAPHICAL REGIONS: CANADA MEXICO CENTRAL AMERICA SOUTH AMERICA BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This docum ent is an agreement (“ Agreemen t”) between Y ou, t he end ...

  • Cabletron Systems 6000 - page 6

    iv If the Program is ex ported f rom the Uni ted States pursua nt to the License Ex ception TSR un der the U.S . Export Administ ration Re gulations, in addition to the restricti on on transfe r set forth in Section s 1 or 2 of this Agreement, Y ou agree not to (i ) reex port or release the Pr ogram, the source co de for the Program or technology t ...

  • Cabletron Systems 6000 - page 7

    v CABLETRON SYSTEMS SALES AND SERVICE, INC. PROGRAM LICENSE AGREEMENT IMPOR T ANT : THIS LICENSE APPLIES FOR USE OF PR ODUCT IN THE UNITED ST A TES OF AMERICA AND BY UNITED ST A TES OF AMERICA GO VERNMENT END USERS. BEFORE OPENING OR UTILIZING THE ENCLOSED PR ODUCT , CAREFULL Y READ THIS LICENSE A GREEMENT . This docu ment is an a greement (“ Agr ...

  • Cabletron Systems 6000 - page 8

    vi 5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The encl osed P rod uc t (i ) was d ev elop e d so le ly at private expense; (ii) conta ins “restric ted computer software” submitted with restricted rights in accord ance with section 52.227-19 (a) through (d) of the Commerc ial Computer Software-Restricted Rights Clause and its su ccessors, an ...

  • Cabletron Systems 6000 - page 9

    vii CABLETRON SYSTEMS LIMITED PROGRAM LICENSE AGREEMENT IMPOR T ANT : THIS LICENSE APPLIES FOR THE USE OF THE PR ODUCT IN THE FOLLO WING GEOGRAPHICAL REGIONS: EUR OPE MIDDLE EAST AFRICA ASIA A USTRAL IA P A CIFIC RIM BEFORE OPENING OR UTILIZING THE ENCLOSED PR ODUCT , CAREFULL Y READ THIS LICENSE A GREEMENT . This doc ument is an agreement (“ Agr ...

  • Cabletron Systems 6000 - page 10

    viii If the Program is exported from the United States pursuant to the Li cen se Exception TSR under the U.S. Ex po rt Administ ration Re gulations, in addition to the restricti on on transfe r set forth in Section s 1 or 2 of this Agreement, Y ou agree not to (i ) reex port or release the Pr ogram, the source co de for the Program or technology to ...

  • Cabletron Systems 6000 - page 11

    ix SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS THE GPIM-01 AND GPIM-09 GIGABIT ETHERNET MODULE S USE CLASS 1 LASER TRANSCEIVERS. READ THE FOLLOWING SAFETY INFORMATION BEFORE INSTALLIN G OR OPERATING THESE M ODULES. The Class 1 laser transcei vers use an o p tical fe edba ck loop to mainta in Class 1 operation limits. Th is control lo op eliminate ...

  • Cabletron Systems 6000 - page 12

    x DECLARATION OF CONFORMITY Appl icatio n o f Coun cil D irec ti ve(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manuf acturer’ s Addr ess: 35 Indu st rial Way PO Box 50 05 Rochest er, NH 03867 Europe an Representati ve Name: Mr. J. Solari Europe an Represen tative Address: Cablet ron Syst ems Li mited Nexus H ous e, Ne ...

  • Cabletron Systems 6000 - page 13

    xi Contents Figure s ...... ....... ...... ....... ....... ........ ....... ....... ...... ....... ......... ...... ....... ....... ...... ......... ....... . .... xiii Tables ........ ............. ............ . ....... ............. .......... ........... ........... ............. ............. ......... .... xiv ABOUT THIS GUIDE Using This Guid ...

  • Cabletron Systems 6000 - page 14

    xii 2 NETWORK REQUIREMENTS 2.1 Smar tT runk ..... .......................... .................... ................... ................... ............. 2-1 2.2 10BASE-T Ne twork .................. .......................... ................... .................... ...... 2-1 3 INSTALLATION 3.1 Required Tool s ......................... ............. ...

  • Cabletron Systems 6000 - page 15

    xiii Figures Figure Pa g e 1-1 The 6E233-49 SmartSw itch .. .................... ................... ................... .......................... ...... 1-2 3-1 Installing an Interface Module ............ ....... ...... ....... ...... ....... ...... ...... ....... ................... ...... 3-4 3-2 S traight Cable Connec tion .... ............... ...

  • Cabletron Systems 6000 - page 16

    xiv Ta b l e s Ta b l e P age 3-1 Contents of 6E233-49 S martSwitch Carton ............... ................... ................... .............3-2 4-1 LANVIEW LEDs CPU, Rec eive, and Trans mit Status .................. ................... .............4-3 4-2 Fault Identific ation . ................... .................... ........................ ...

  • Cabletron Systems 6000 - page 17

    xv About This Guide W e lcome t o the C able tr on Sy stems 6E233-49 SmartSwit ch 6000 Interface Modul e User’s Guide . This gui de descri bes the SmartSwitc h module and pro vides informati on concerning netw ork requ irements, i nstallation, and troubl eshooting. F or inf ormation ab out ho w to use L ocal Management t o conf igure and manage t ...

  • Cabletron Systems 6000 - page 18

    Stru cture of This Guide xvi STRUCTURE OF THIS GUIDE This gui de is orga nized as follo ws: Chapter 1 , In troduction , o utlines the conten ts of thi s manual, descr ibes the fe ature s of the SmartS witch module , and provide s instructions for gett ing additional help. Th is chapte r also include s a list of technology a nd user guides t hat may ...

  • Cabletron Systems 6000 - page 19

    Related Doc uments xvii RELATED DOCUMENTS • SmartSwit ch Series 6H202, 6H203, 6H252 , 6H253, 6H258, 6H259, 6H262, 6E23 3, and 6E253 Local Mana gement User’ s Guide • 6C105 SmartS witch 6000 Over view and Se tup Guide • Ethernet T ec hnology Guid e • Cabling Gui de • 802.1Q VLAN User ’ s Guide • SmartT runk User’ s Guide The foll o ...

  • Cabletron Systems 6000 - page 20

    Related Docum ents xviii DOCUMENT CON VENTIONS The foll owing con v entions are u sed throug hout this document : NO TE Note symbol. Cal l s the reader’ s attention to an y item of inf ormation that m a y be of special impor tance. TIP Tip symbol. Conv eys hel pful hi nts concer ning procedures or actions . ! CAUTI O N Caution symbol. Contains in ...

  • Cabletron Systems 6000 - page 21

    Introducti on 1-1 1 Intr oduction This chap ter introduces the 6E233-49 SmartS w it ch 6000 de vice and pro vides infor m ati on about ho w to obtain addit ional support f rom Cabl etron Syst ems. 1.1 OVERVIEW The 6E233-4 9 SmartSwitch, sho wn in Figure 1-1 , is an Ether net interf ace module f or the Cabletr on Sys te ms 6C105 c has si s. The 6E23 ...

  • Cabletron Systems 6000 - page 22

    Ov er vie w 1-2 Introduc tion Figure 1-1 The 6E 233-49 Smar tSw itch ETHERNET 6E233-49 24 48 37 36 25 24 1 12 5 9 67 8 10 11 12 1234 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 13 RESET COM CPU 2693_01 RESET Button CPU LED COM P or t Receive (RX) T ransmit (TX) LEDs HSIM Slot 48 P or t ...

  • Cabletron Systems 6000 - page 23

    Ov er vie w Introdu ction 1-3 1.1.1 Connectivity The 6E233-4 9 SmartSwitch connec ts to Ethernet networks or w orkstations through t he four RJ21 connecto rs on the front panel. Thes e ports support Un shielded T wisted P air (UTP) cabl es with an impeda nce between 85 and 111 ohms at le ngths up to 100 me ters. These port s are IEEE 802.3u 10B ASE ...

  • Cabletron Systems 6000 - page 24

    Ov er vie w 1-4 Introduc tion 1.1.4 Full Duplex Switched Ethernet Each sw itched Et hernet por t on the 6E233-49 S m art Switch can b e configur ed to o perate i n Full Duple x Switched Ethernet (FDSE) mode. FDSE allo ws each port t o prov ide up to 2 0 Mbps of band width. 1.1.5 SmartT r unk SmartT runk, a lso refe rred to as SmartT run king, is Ca ...

  • Cabletron Systems 6000 - page 25

    Ov er vie w Introdu ction 1-5 1.1.8 P or t/VLAN Redirect Functio ns The port redirect funct ion, also referred to as “Port Mirr oring,” is a tr oubleshooting t ool used t o map traf fi c from a single sour ce port to a sing le destinatio n port wit hin the de vice. This fe ature allo ws frames, inc luding those wit h errors to be c opied and se ...

  • Cabletron Systems 6000 - page 26

    Ov er vie w 1-6 Introduc tion 1.1.10 GARP Switch Operation Some or all port s on th e switch may be activ ated to o perate und er the Generic At trib ute Regi strati on Protocol (GARP) appli cations , GARP VLAN Regi strati on Protoco l (GVRP) and/ or GARP Multicast R e gistra tion Protocol (GMRP). GARP is a proto col, or s et of ru les, th at outl ...

  • Cabletron Systems 6000 - page 27

    Ov er vie w Introdu ction 1-7 1.1.14 Distributed Chassis Management From a manage m ent perspect i ve, the 6C105 SmartSwitch 6000 chassis can be vie wed as a sin gle entity with a single IP address. Its sys tems mana gement func tions are dist rib uted to all modul es. The chass is can be managed us ing a single IP a ddress, or the modul es can be ...

  • Cabletron Systems 6000 - page 28

    Getting H elp 1-8 Introduc tion 1.2 GETTING HELP F or addit ional supp ort related t o this de vice or document, co ntact Cabletron Systems usi ng one of the follo wing methods: Befo re cal ling Ca blet ro n Sys t ems, h ave th e follo wing in forma tion re ady: • Y our Cabletr on Systems s ervice contrac t number • A descri ption of the f ailu ...

  • Cabletron Systems 6000 - page 29

    Network Requirement s 2-1 2 Netw ork Requirements Before i nstalli ng the 6E233-49 Sm artSwitch , revi ew the re quiremen ts and spe cificat ions referred to in t his chapter conc er nin g the SmartT runk f eat ur e ( Section 2.1 ) and the10B ASE-T T wisted P air Netw ork ( Sect ion 2.2 ). The netw ork installat ion must meet the guideline s to ens ...

  • Cabletron Systems 6000 - page 30

    ...

  • Cabletron Systems 6000 - page 31

    Install ation 3-1 3 Installa tion This chap ter provid es the instruct ions r equired t o instal l the 6E233-49 Sm artSwitc h. Follo w the order of the sect ions listed be lo w to ensure a pr oper inst alla tion: • Required tools ( Section 3.1 ) • Unpacking the 6E233-49 SmartSwi tch ( Section 3.2 ) • Instal ling Opti ons ( Section 3.3 ) • I ...

  • Cabletron Systems 6000 - page 32

    Installi ng Op tio n s 3-2 Insta llation . 3.3 INSTALLING OPTIONS If the 6E233-49 SmartSwi tch is to be installed wi th an op tional HSI M, refer to the i nstallation instr uct ion s shi ppe d with t he HSIM. The HSIM must be ins ta ll ed bef or e the 6E233- 49 is i nst al led in the c hassis. 3.4 INSTALLING THE 6E233-4 9 SMAR TSWITCH INTO THE 6C10 ...

  • Cabletron Systems 6000 - page 33

    Installi ng the 6E2 33-49 Smar tS witch in to the 6C105 Chassis Install ation 3-3 3. Locate the anti static wri st strap shi pped with the 6C105 chas sis. Attach the antis tatic wrist st rap to your wr ist and plug the cable from the an tistatic wri st strap into the ESD groundi ng recept acle at the uppe r right corn er of t he 6C105. 4. Remove t ...

  • Cabletron Systems 6000 - page 34

    Installi ng the 6E2 33-49 Smar tS witch in to the 6C105 Chassis 3-4 Insta llation Figure 3-1 Installing an Inter face Module 1 2 3 45 PS1 PS2 Plastic Locking T ab Slot Number 2693-02 2159-01 Circuit Card Card Guides Metal Back-Panel Plastic Locking T ab Backplane Connector ETHERNET 6E233-49 24 48 37 36 25 24 1 12 5 9 67 8 10 11 12 1234 13 14 15 16 ...

  • Cabletron Systems 6000 - page 35

    Connecti ng to the Networ k Install ation 3-5 3.5 CONNECTING TO THE NET W ORK This s ection pr ovides the pro cedures fo r connecti ng unshiel ded twis ted pair ( UTP) se gments to the modules. T o make conne ctions to an optional HSIM instal led in the HSIM slot of a Smar tSwitch, r efer to the instru ctions shipped wi th tha t de vice. When fac i ...

  • Cabletron Systems 6000 - page 36

    Connectin g to the Networ k 3-6 Insta llation Figu re 3 -2 S tra ight Cable Con nect ion ETHERNET 6E233-49 24 48 37 36 25 24 1 12 5 9 67 8 10 11 12 1234 13 RESET COM CPU 2693_07 RJ21 Screw Screw Port 1 LED RX TX 1 ...

  • Cabletron Systems 6000 - page 37

    Connecti ng to the Networ k Install ation 3-7 Figure 3-3 Connection Us ing the RJ21 Angle A dapter 3. Tighten the two screws on t he RJ21 s traight cable connector or RJ21 angle adapt er, as appli cable , to sec ure it to the d evic e. 4. If using the RJ21 angl e ada pter, plug the RJ21 righ t- angl ed conne cto r as shown in Fi gure 3-3 . Dependin ...

  • Cabletron Systems 6000 - page 38

    Completin g the Insta llation 3-8 Insta llation b. Verify that the RJ21 conne ctor associat ed with the twisted pair segment has the proper pino uts and che ck the cable for conti nuity. c. Check tha t the twisted pai r conn ection meets the dB l os s and cable spec if ic ations outline d in Chapt er 2 . If a l ink is not established, co ntact Cabl ...

  • Cabletron Systems 6000 - page 39

    T ro ubl eshooti ng 4-1 4 T r oub leshooting This chap ter provid es information c oncerning t he follo wing: • Using the LANVIEW diagnostic and s t atus monitori ng system ( Sectio n 4.1 ) • T roubleshoo ting netw ork and module operatio nal probl ems ( Section 4 .2 ) • Using the RESET b utton ( Sect ion 4.3 ) 4.1 USING LANVIEW The 6E233-4 9 ...

  • Cabletron Systems 6000 - page 40

    Using LANVIEW 4-2 T roubleshoot ing Figure 4-1 LANVIEW LEDs ETHERNET 6E233-49 24 48 37 36 25 24 1 12 5 9 67 8 10 11 12 1234 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 13 RESET COM CPU 2693_09 CPU LED RX TX 1 ...

  • Cabletron Systems 6000 - page 41

    Using LA NVIEW T r oubleshooting 4-3 NO TE NO TE NO TE NO TE The ter ms flashing , bl inking , and solid used in th e LED definition tab les of this chapter ind i cate the f ollo wing: Flashing indi cates an irregul ar LED pulse. Blinking in dicates a steady LED pulse, (appr oximatel y 50% on, 50% off). Solid indicat es a steady LED light. No pul s ...

  • Cabletron Systems 6000 - page 42

    Using LANVIEW 4-4 T roubleshoot ing TX Of f Port enab led, and no acti vity . Should fl ash green e very tw o seconds i ndicating BPDUs bein g sent if ST A is enab led and th ere is a valid link. 1. Ensure that the ST A is enable d and that th ere is v alid lin k. The Local Manag ement User’ s Guide descr ibes ho w to enable th e ST A. 2. Contact ...

  • Cabletron Systems 6000 - page 43

    T r oubleshooting Checklist T r oubleshooting 4-5 4.2 T R OU BLESHOOTING CHECKLIST If th e 6 E233-49 SmartSwitch is not w or kin g pr ope rly , ref er t o Ta b l e 4 - 2 for a checkl ist of pos sib le problems, causes, and recommend ed actions to re solve the pr oblem. T able 4-2 Fa ult Iden ti fica tion Symptom P ossible Cause s All L E Ds are o f ...

  • Cabletron Systems 6000 - page 44

    T ro ubl eshooting Checklist 4-6 T roubleshoot ing T able 4-3 P ower Syst em T roubleshooting P os sible Causes Instruction Loss of po wer to the 6C105 chassi s. Perfor m the fol lo wing steps: 1. Check ON/OFF swit ches of 6C105 po wer su pplies. All switche s must be in the ON ( | ) posi tion. 2. Check all po wer cords and cabl es for proper c onn ...

  • Cabletron Systems 6000 - page 45

    T r oubleshooting Checklist T r oubleshooting 4-7 T a ble 4-4 Firmware T roubleshooting P oss ible Cause Instruction Autobaud en abled. Press ENTER (RETURN) (may tak e up to four times). T erminal setup is not co rrect . Refer to the Local Managem e nt Use r’ s G uide for s etup procedur es. Imprope r cons ole cable pinouts. Refer to Appendix A f ...

  • Cabletron Systems 6000 - page 46

    T ro ubl eshooting Checklist 4-8 T roubleshoot ing T able 4-5 Management System T r oubleshooting P ossi ble Causes Instruction Cannot ac cess Local Management. 1. Fir mware ima ge faul t - refe r to Ta b l e 4 - 4 . 2. Management syst em fault - re fer to Ta b l e 4 - 5 . Cannot con t act dev ice through in- ban d manageme nt. 1. Management Sy ste ...

  • Cabletron Systems 6000 - page 47

    T r oubleshooting Checklist T r oubleshooting 4-9 T able 4-6 Device Setup T roubleshooting P oss ible Causes Instructio n The 6E233-49 SmartSwitch detect a looped conditi on. 1. V e rify th at Span ning Tree is en abled . Refer to the Local Manage ment User’ s Guide for i nstru ctions on setting the type of ST A. 2. Re vie w network de sign an d ...

  • Cabletron Systems 6000 - page 48

    Usi ng t h e RESET B u tton 4-10 T roubleshoot ing 4.3 USING THE RESET BUTTO N The RESET b utton, locate d near the upper plastic locki ng tab of t he module (r efer to Figu re 4-2 ), reset s the 6E233- 49 SmartSwitch proc essor without af fectin g the NVRAM. Figure 4-2 RESET But ton T o reset t he 6E233 -49 SmartS witch pro cessor , press and rele ...

  • Cabletron Systems 6000 - page 49

    Specif ications A-1 A Spe cifica tions This appen dix pro vides operating spe cif ication s for the Cab letron Sys tems 6E233-49 Smar tSwitch Interf ace Module. Cable tron Syst ems reserv es the r ight to ch ange th ese speci ficatio ns at an y time without not ice . A.1 MODULE SPECIFICATIONS A.2 PH YSICAL PROPERTIES A.3 EN VIR ONMENTAL REQUIREMENT ...

  • Cabletron Systems 6000 - page 50

    Input/Outp ut P or ts A-2 Specif ications A.4 INPUT/OUTPUT P ORTS 6E233-49 Specifications A.5 COM P ORT PINOUT ASSIGNMENTS The COM port i s a serial co mmunicati ons port that suppor ts Local Ma nagement or con nection to a UPS. Ta b l e A - 1 shows the COM port pin assignments: A.6 REGULATOR Y COMPLIANCE T h is e q u ip m e n t m e ets th e fo llo ...

  • Cabletron Systems 6000 - page 51

    Optiona l Installati ons and M ode Switc h Bank Setti ngs B-1 B Opti ona l In st al lat ions and Mode Swit ch Bank Settings This appe ndix cov ers the follo wing items: • Required tools ( Section B.1 ) • Locatio ns, functions, and settings for the m ode switches ( Sectio n B.2 ) • Instal ling the SIMM ( Secti on B.3 ) • Instal ling HSIM s ( ...

  • Cabletron Systems 6000 - page 52

    Setting th e Mode Swi tches B-2 Optiona l Instal lations a nd Mode Sw itch Ban k Setting s Figure B-1 M odule Mode Switch Lo cation/Component La yout Switch de fi nitions and posi tions are as fo llo ws: • Switches 1 through 4 – For Cabl etron S ystems use o nly . • Switch 5 – COM Por t Auto baud. The defau lt (OFF) positi on enables Autoba ...

  • Cabletron Systems 6000 - page 53

    SIMM Upgrade Option al Instal lations and Mode S witch Ba nk Settin gs B-3 • Switch 8 – Reset P assword/Communi ty Strings. Changi ng the positio n of this switch clears only the user-ent ered pass words stored i n NVRAM , and r estores the default passw ords. Once the Sm artSw itch resets , the pa sswor ds can either b e reen tered or the defa ...

  • Cabletron Systems 6000 - page 54

    SI MM Up g rad e B-4 Optiona l Instal lations a nd Mode Sw itch Ban k Setting s B.3.2 Installing th e DRAM SIMM T o install a DRAM SIMM, ref er to Figure B-3 and proceed as f ollow s: 1. With the SIMM ali gnment n otch orie nted as shown in Figure B-3 , insert the SIMM down between t he conn ector te eth. 2. Pivot t he SIMM downward s o the connect ...

  • Cabletron Systems 6000 - page 55

    Installi ng Optional High Speed I nterface Modules Option al Instal lations and Mode S witch Ba nk Settin gs B-5 B.4 INSTALLING OPTIONAL HIGH SPEED INTERFACE MODULES Figure B- 4 sho ws the locat ion of the connec t or for an opti onal High Spe ed Interfac e Module (HSIM) . Figure B-4 HSIM Con nector Locatio n NO TE NO TE NO TE NO TE Refer to the i ...

  • Cabletron Systems 6000 - page 56

    ...

  • Cabletron Systems 6000 - page 57

    Index-1 Inde x Numerics 10BA SE-T requirem ents 2-1 C Cable specifications 100BASE- T network 2-1 COM port pin as s ignm ents A-2 Connect ing to the netwo rk 3-5 D Documents, related xvii E Enviro nmental r equireme nts A-1 I Installation Fast Ethernet Interface Module B-5 L LANVIEW LEDs 4-1 LDRAM installation B- 4 M Memory upgradin g B-3 P Physica ...

  • Cabletron Systems 6000 - page 58

    Index-2 T Troubleshoo ting 4-1 checklist 4-5 U Unpacking 3-1 V VLAN Redirect F u nction, intr oductio n to 1-5 ...

Fabbricante Cabletron Systems Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoCabletron Systems 6000 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Cabletron Systems
- manuali per l’uso 6000
- schede prodotto Cabletron Systems
- opuscoli
- o etichette energetiche Cabletron Systems 6000
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Cabletron Systems 6000.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Cabletron Systems 6000, manuali di manutenzione, brevi manuali o manuali utente Cabletron Systems 6000. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Cabletron Systems 6000.

Manuali per l’uso simili

Manuale completo del dispositivo Cabletron Systems 6000, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Cabletron Systems 6000 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Cabletron Systems 6000.

Il manuale per l’uso completo Cabletron Systems, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Cabletron Systems 6000 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Cabletron Systems 6000, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Cabletron Systems 6000 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Cabletron Systems 6000 - che ci dovrebbe aiutare nei primi passi durante l'uso Cabletron Systems 6000
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Cabletron Systems 6000
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Cabletron Systems 6000 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Cabletron Systems 6000?

Utilizza il modulo sottostante

Se non hai risolto il problema con Cabletron Systems 6000 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Cabletron Systems 6000 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine