  • FMI C42MW - page 1

    For more information, visit www .fmiproducts.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers.  ? ...

  • FMI C42MW - page 2

    www .fmiproducts.com 108919-01H 2 SAFETY                     the manufacturer's instructions     ...

  • FMI C42MW - page 3

    www .fmiproducts.com 108919-01H 3 SPECIFICA TIONS 0" TO BOTTOM OUTSIDE AIR (LEFT SIDE ONL Y) TOP SP ACERS 3/4" AIR SP ACE BACK AND SIDES HEARTH EXTENSION 66" X 20" 12" EACH SIDE 1" AIRSP ACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0" TO MA TERIAL NO COMBUSTIBLE MA TERIA L ON FACE GAS LINE KNOCK OUT AIR KIT KNOCK OUT ...

  • FMI C42MW - page 4

    www .fmiproducts.com 108919-01H 4 FIREPLACE INST ALLA TION   T o det erm ine safes t and most efci ent locat ion for replace, you must take into consideratio n the following guidelines: 1. Locat ion must allow for prope r clearance s (see Figures 1 and 2). 2. Consider a location where r ...

  • FMI C42MW - page 5

    www .fmiproducts.com 108919-01H 5  A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of replace opening is required to protect combustible oor construction in front of replace. Fabricate a hearth extension using a material which meets t ...

  • FMI C42MW - page 6

    www .fmiproducts.com 108919-01H 6 FIREPLACE INST ALLA TION Continued Figure 4 - Mantel Clearances to Combustible Material Electrical Bushing Electrical Cover Plate Rocker Switch Figure 6 - Fan Switch-Electrical Bushing Electrical Housing Wire Nut (3x) (Not Supplied) Outer Wrapper of Fireplace Electrical Cover Plate and Electrical Bushing Fireplace ...

  • FMI C42MW - page 7

    www .fmiproducts.com 108919-01H 7 Figure 8 - Lineal Gain      42" Fireplace 37 1 / 2 " 12-8DM Pipe Section 10 5 / 8 " 18-8DM Pipe Section 16 5 / 8 " 24-8DM Pipe Section 23 5 / 8 " 36-8DM Pipe Section 34 5 / 8 " 48-8DM ...

  • FMI C42MW - page 8

    www .fmiproducts.com 108919-01H 8 VENTING INST ALLA TION Continued Figure 9 - T ypical Offset Installation Return Elbow Offset Elbow Return Elbow Offset Elbow 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. 6' Max. Return Elbow Offset Elbow Offset Elbow Return Elbow A B C Offset Elbow Ceiling Support Pipe 12S-8DM Return Elbow ...

  • FMI C42MW - page 9

    www .fmiproducts.com 108919-01H 9 Figure 1 1 - Elbow Offset B A Screws Figure 10 - Ceiling Support Pipe 12S-8DM    A B 48"  24" 18" 12" 4 3 / 8 " 16 3 / 8 " ELBOW SET ONL Y 9 3 / 4 " 25 1 / 2 " 1 12 3 / 4 " 30 3 / 4 " 1 ...

  • FMI C42MW - page 10

    www .fmiproducts.com 108919-01H 10 VENTING INST ALLA TION Continued Pitch Slope Opening    Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45.0° 20 3 / 8 " V12F-8DM 4. Remove shingles around opening mea - sured. Cut o ...

  • FMI C42MW - page 11

    www .fmiproducts.com 108919-01H 11 Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 15 - Flashing Installation Figure 16 - Storm Collar Chimney Pipe W aterproof Caulk Storm Collar Flashing Storm Collar Installation (SC1 or SC2) Place storm collar over pipe and slide down unti ...

  • FMI C42MW - page 12

    www .fmiproducts.com 108919-01H 12 10' 2' Min. 10' 3' Min. 2' Min. 3' Min. Level of Flue Gas Outlet Figure 19 - 10 Foot Rule  All ue gas outlet chimney terminations must extend a minimum of 3 feet in height above high est poin t where it passe s throug h roof and must be at least ...

  • FMI C42MW - page 13

    www .fmiproducts.com 108919-01H 13 OPTIONAL GAS LINE INST ALLA TION Figure 21 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel Gas line hook up should be done by your supplier or a qualied service person. Note: Before you proceed, make sur ...

  • FMI C42MW - page 14

    www .fmiproducts.com 108919-01H 14 OPTIONAL GAS LINE INST ALLA TION Continued       has been used for wood burn-      be cleaned of soot, creosote and   ? ...

  • FMI C42MW - page 15

    www .fmiproducts.com 108919-01H 15 Figure 24 - Damper Handle Location OPERA TION AND MAINTENANCE Continued   Damper handle, which opens and closes damper blade, is located inside rebox at cen ter tow ards ba ck wall ( see Fig ure 24) . Pushing handle back into keyway slot will ...

  • FMI C42MW - page 16

    www .fmiproducts.com 108919-01H 16 P ARTS  1 1 27 30 23 22 24 10 14 25 4 17 3 2 1 5 20 28 12 7 15 9 16 13 8 26 6 29 19 18 21 ...

  • FMI C42MW - page 17

    www .fmiproducts.com 108919-01H 17 P ARTS  This list contains replaceable parts used in your replace. When ordering parts, see Replace- ment Parts on page 18 of this manual.  NO.   ? ...

  • FMI C42MW - page 18

    www .fmiproducts.com 108919-01H 18    ACCESSORIES     ? ...

  • FMI C42MW - page 19

    www .fmiproducts.com 108919-01H 19               ? ...

  • FMI C42MW - page 20

    108919-01 Rev . H 09/09 This product is manufactured for Style Crest Inc. under the VEXAR brand name by: FMI PRODUCTS, LLC 2701 S. Harbor Blvd. Santa Ana, CA 92704 www .fmiproducts.com ...

Fabbricante FMI Categoria Indoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoFMI C42MW possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici FMI
- manuali per l’uso C42MW
- schede prodotto FMI
- opuscoli
- o etichette energetiche FMI C42MW
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso FMI C42MW.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione FMI C42MW, manuali di manutenzione, brevi manuali o manuali utente FMI C42MW. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto FMI C42MW.

Manuali per l’uso simili

Manuale completo del dispositivo FMI C42MW, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare FMI C42MW dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti FMI C42MW.

Il manuale per l’uso completo FMI, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale FMI C42MW - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice FMI C42MW, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per FMI C42MW che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo FMI C42MW - che ci dovrebbe aiutare nei primi passi durante l'uso FMI C42MW
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del FMI C42MW
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio FMI C42MW in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su FMI C42MW?

Utilizza il modulo sottostante

Se non hai risolto il problema con FMI C42MW con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con FMI C42MW è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)