Smeg GD100XG - page 1
21 T able of Content s INSTRUCTIONS FOR THE USER : these pro vide recommendations for use, a description of the controls and the correct procedures for cleaning and maintaining th e app liance INSTRUCTIONS FOR THE INST ALLER : these are intended for the qualified engineer who is to install, commission and test the applian ce 1. PRECAUTIONS FOR U SE ...
-
Smeg GD100XG - page 2
22 Precautions f or Use 1. PRECA UTIONS FOR USE THIS MANU AL IS AN INTEGRAL P ART OF THE APPLIANCE. T AKE GOOD CARE OF IT AND KEEP IT T O HAND TH ROUGHOUT THE HOB'S LIFE CYCLE. WE URGE Y OU TO READ THIS MANU AL AND ALL THE INFORMA TION IT CONT AINS CAREFU LL Y BEFORE USING THE APPLIANCE. INST ALLA TION MUST BE CARRIED OUT BY QU ALIFIED ST AFF ...
-
Smeg GD100XG - page 3
23 Disposal instructions 2. DISPOSAL INSTRUCTIONS - OUR EN VIRONMENT POLICY Our products are only packaged using non-pollutant, environment-friendly , recyclable materials . We urge y ou to cooperate b y disposing of the packaging properly . Contact your local dealer or the competent local organisati ons f or the add resses of collection, recycling ...
-
Smeg GD100XG - page 4
24 Safety Precautions 3. SAFETY PRECAUTIONS SEE INST ALLA TION INSTRUCTIONS FOR SAFETY REGULA TIONS FOR ELECTRIC OR GAS APPLIANCES AND FOR VENTILA TION F UNCTIONS. IN Y OUR INTEREST AND TO ENSURE Y O UR SAFETY , BY LA W ALL ELECTRIC APPLIANCES MUST ONL Y BE INST ALLED AND SER VICED BY QU ALIFIED ST AFF , IN ACCORD ANCE WITH THE RELEV ANT REGULA T I ...
-
Smeg GD100XG - page 5
25 Instructions f or the User 4. GETTING T O KNO W Y OUR APPLIA NCE 5. BEFORE INSTALLATION A uxiliar y Bur ner (A UX) Rapid Bur ner (R) Semi-rapid (SR) b urner Ultrarapid Burner (UR3) Raised spoke pan stand Nev er l eav e packaging residues unattended in the home. Separate waste packaging materials by type and consign them to the nearest separate d ...
-
Smeg GD100XG - page 6
26 Instructions f or the User 6. USING THE HOB 6.1 Gas hob Before lighting the hob burners check that the flame diffuser rings are correctly in place with their respec tive b u rner caps, making sure that the holes A in the flame diffusers are aligned with the plugs and ther mocouples. The optional grid B is for use with w oks. T o prev ent damage ...
-
Smeg GD100XG - page 7
27 Instructions f or the User 6.2 Practical hints f or using the bu rners F or better bur ner efficiency an d to minimise ga s consumption, use pans with flat, ev en bottoms with lid and of suitable size f or the burner , so that flames do not reach up the sides of the pan (see point "6.3 P an diameters"). Once the contents come to the bo ...
-
Smeg GD100XG - page 8
28 Instructions f or the User 7. CLEANING AND MAINTENANCE NEVER USE A JET OF STEAM FOR CLEANING THE APPLIANCE. Before carrying out any operations, disconnect the appliance from the electricity supply . 7.1 Cleaning s tainless stee l T o keep stainless steel in good condition, it must be cleaned regularly , after each use of the appliance, first all ...
-
Smeg GD100XG - page 9
29 Instructions f or the Installer 8. FITTING THE APPLIANCE 8.1 Fitting the ap pliance in the top This appliance is in class 3. The procedures required below must be carried out by a skilled builder and/or joiner . The hob can be installed on various mater ials, including masonr y , metal, solid wood and wood finished with plastic lamina tes, provi ...
-
Smeg GD100XG - page 10
30 Instructions f or the Installer 8.1.2 Installation to a fl ush mounting structure Make a hole in the top of the cabine t of the size shown in the figure, lea ving a spac e " X " of at least 110 mm from the rear edg e. The underside of the casing must be fully accessible once the ap pliance has been installed. This appliance may be inst ...
-
Smeg GD100XG - page 11
31 Instructions f or the Installer This type of appli ance also requires a cut 3 mm deep in the top with the dimensions shown in figure 7 (detail A ). Bef ore fitting the hob , apply the adhesive sponge strip sup plied " B " along th e entire surface of the cut (fig. 7). Now place the 12 brack ets supplied to secure the top to the suppor ...
-
Smeg GD100XG - page 12
32 Instructions f or the Installer 8.2 Securing the ap pliance to the cabine t 8.2.1 Securing the side brac kets Fit the two provided brac kets to the shor t sides of the appli ance as shown in figura 4-5 4) 5) 8.2.2 Securing the fr ont/rear brackets The hob is eq uipped with 10 brack ets " A " (see f ig. 6) whic h secure a nd lev el it r ...
-
Smeg GD100XG - page 13
33 Instructions f or the Installer 8.3 Electrical connection Check that the pow er supply voltage and size are as specified on the nameplate below the a ppliance car t er . The nameplate must ne ver be removed. The appliance must be connected to ear th in compliance with electrical system safety regulations. If a per manent connection is used, t he ...
-
Smeg GD100XG - page 14
34 Instructions f or the Installer 9. GAS CONNECTION Before installing, chec k that the lo cal gas main (type and pre ssure) and the appliance's setting s are compatible. There are 2 ways to connect the ap pliance to the domestic gas main: 1- Make two branches with a pipe or steel hose an d unite them with a T - fitting just downline of the ga ...
-
Smeg GD100XG - page 15
35 Instructions f or the Installer 9.2 Room ventilati on The appliance may only be installed in a per manently ventilated room as specified by the relev an t regulations. The air flo w into the room where the appliance is installed must be sufficient for proper gas comb ustion and room ventilation. The air intakes , protected by gratings, must be o ...
-
Smeg GD100XG - page 16
36 Instructions f or the Installer 10. AD APTING T O DIFFERENT TYPES OF GAS Before carrying out the operations descr ibed below , disconne ct the appliance from the electr icity supply . The appliance is tested with G20 (2H) na tural gas at the pressure of 20 mbar . If it is to be used with other types of gas, the b u rner nozzles hav e to be chang ...
-
Smeg GD100XG - page 17
37 Instructions f or the Installer 10.2 Burner and Nozzle Data T ables Burner R ATED HEAT CAPACITY ( K W) LPG – G30/G31 28/37 mbar Nozzle diameter 1/100 mm By-pass mm 1/100 Reduced heat capacity (W) Net g/h G30 Net g/h G31 Au x i l i a r y ( ! ) 1.05 50 30 * 28 ** 350 76 75 Semi-rapid (2) 1.75 65 33 * 32 ** 450 127 125 Rapid (3) 2.3 75 45 * 42 ** ...
-
Smeg GD100XG - page 18
38 Instructions f or the Installer 11. FINAL OPERATIONS FOR GAS APPLIANCES After making the adjustments descr ibed above , reassemble the appliance, rev ersing the proc edures described in point "10.1 Changing the hob nozzles". After adjusting f or use of a gas other than th e gas used f or testing the appliance, replace the gas setting l ...
Hai una domanda su Smeg GD100XG?
Utilizza il modulo sottostante
Se non hai risolto il problema con Smeg GD100XG con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Smeg GD100XG è probabile che voglia condividere il modo di risolverlo.