    BREAKER HAMMER Model 94882 ASSEMBL Y AND OPERA TING INSTRUCTIONS Diagrams within this manual may not be drawn proportionally . Due to continuing improvements, actual product may differ slightly from the product described herein. Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: ...

  • Chicago Electric 94882 - page 2

    SKU 94882 P A GE 2 PR ODUCT SPECIFICA TIONS SA VE THIS MANU AL Y ou will need this manual f or the safety warnings and precautions, assembl y , operating, inspection, maintenance and c leaning pr ocedures, parts list and assemb ly diagram. Keep y our in voice with this manual. Write the in voice number on the inside of the fr ont co ver . Keep this ...

  • Chicago Electric 94882 - page 3

    SKU 94882 P A GE 3 2. Do not oper ate po wer tool s in e xplo sive atm osphe res, such as in the pres ence of flammable liquids, gases, or dust. P ower tools create spar ks which ma y ignite the dust or fumes. 3. Keep b ystanders, c hildren, and visitor s away while operating a power tool. Distractions can cause y ou to lose control. Protect other ...

  • Chicago Electric 94882 - page 4

    SKU 94882 P A GE 4 11. Dress properl y . Do not wear loose clothing or je welry . Contain long hair . Keep y our hair , clothing, and gloves a way fr om mo ving par ts. Loose clothes , jew elr y , or long hair can be caught in moving par ts. 12. A void accidental star ting. Be sure the P ower Switch is off before plugging in. Carr ying power tools ...

  • Chicago Electric 94882 - page 5

    SKU 94882 P A GE 5 W ARNING! Improperl y connecting the gr ounding wire can result in the risk of electric shock. Check with a qualified electrician if y ou are in doubt as to whether the outlet is properl y gr ounded. Do not modify the power cor d plug provided with the tool. Never remove the gr ounding pr ong from the plug. Do not use the tool i ...

  • Chicago Electric 94882 - page 6

    SKU 94882 P A GE 6 FIGURE A DOUBLE INSULA TED TOOLS: TOOLS WITH TWO PR ONG PLUGS 4. T ools marked “Doub le Insulated” do not require grounding. The y hav e a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association, and th ...

  • Chicago Electric 94882 - page 7

    SKU 94882 P A GE 7 EXTENSION CORDS 1. Grounded tools require a three wire e xtension cord. Double Insulated tools can use either a two or three wire e xtension cord. 2. As the distance from the supply outlet increases, y ou must use a hea vier gauge e xtension cord. Using e xtension cords with inadequately sized wire causes a serious drop in voltag ...

  • Chicago Electric 94882 - page 8

    SKU 94882 P A GE 8 SYMBOLOGY V ~ A xxxx/min. Double Insulated Canadian Standards Association Underwriters Laboratories, Inc. V olts Alternating Current Amperes No Load Rev olutions per Minute (RPM) no SPECIFIC SAFETY R ULES 1. Maintain labels and nameplates on the Breaker Hammer . These carr y impor tant inf or mation. If unreadab le or missing, co ...

  • Chicago Electric 94882 - page 9

    SKU 94882 P A GE 9 6. W ARNING! P eople with pacemak ers should consult their ph ysician(s) bef ore using this product. Electromagnetic fields in close pro ximity to a hear t pacemaker could cause interf erence to or f ailure of the pacemaker . W ARNING: Alwa ys wear ANSI-approv ed impact saf ety goggles. W ear a full face shield if you are produc ...

  • Chicago Electric 94882 - page 10

    SKU 94882 P A GE 10 UNP A CKING When unpacking, chec k to make sure all par ts shown on the P arts Lists and Assembly Diagrams on pages 12-14 are included. If any par ts are missing or broken, please call Harbor F reight T ools at the number shown on the cov er of this manual as soon as possible . ASSEMBL Y INSTRUCTIONS How to attac h and adjust th ...

  • Chicago Electric 94882 - page 11

    SKU 94882 P A GE 11 OPERA TING INSTRUCTIONS IMPORT ANT - READ BEFORE USE This Breaker Hammer may ha v e decreased performance for a br ief per iod at the begin- ning of each use. This warm-up period lasts appro ximately 3-5 min utes. This happens because the grease inside the tool ma y be thic k, prev enting the tool from operating at full efficie ...

  • Chicago Electric 94882 - page 12

    SKU 94882 P A GE 12 Chipping in a straight line with a chisel bit 1. Use chalk or another suitable writing material and mar k y ou work surf ace to delineate the area you intend to hammer . 2. Plug in the Breaker Hammer . 3. Grasp the main Handle (90) and side Handle (90) fir mly with both hands. When you are sure that no people or animals are in ...

  • Chicago Electric 94882 - page 13

    SKU 94882 P A GE 13 P ARTS LIST 1 Bushing 1 2 Pin 1 3 Ring 1 4 Pin 1 5 Screw M6X40 6 6 W asher 6 7 Spring W asher 6 8 Collet 1 9 O Ring 1 10 O Ring 1 11 O Ring 1 12 Spindle Cov er 1 13 Seal 1 14 O Ring 1 15 Rear Bushing 1 16 Beat Piece 1 17 Bushing 1 18 Damper 1 19 Bushing 1 20 O Ring 1 21 Seal 1 22 O Ring 1 23 O Ring 1 24 Cylinder Slee v e 1 25 Ra ...

  • Chicago Electric 94882 - page 14

    SKU 94882 P A GE 14 P ARTS LIST CONTINUED 82 Bearing 600NSK 1 83 W asher 1 84 Magnetism Ring 1 85 Rotor 1 86 Screw ST5X70 2 87 Stator 1 88 Housing 1 89 Glass Fiber pipe 1 90 Handle 1 91 Screw M5X18 6 92 W asher 6 93 Spring W asher 6 94 Screw M4X12 1 95 Cord Clip 1 96 Gear Case 1 97 O Ring 1 98 Bearing 6304NSK 1 99 Crank Shaft 1 100 Cov er 1 101 Spr ...

  • Chicago Electric 94882 - page 15

    SKU 94882 P A GE 15 ASSEMBL Y DIA GRAM ...

  • Chicago Electric 94882 - page 16

    SKU 94882 P A GE 16 LIMITED 90 D A Y W ARRANTY Harbor F reight T ools Co . mak es e very effor t to assure that its products meet high quality and dur ability standards, and w arrants to the original purchaser that this product is free from def ects in materials and workmanship f or the period of 90 da ys from the date of purchase . This w arranty ...

Fabbricante Chicago Electric Categoria Power Hammer

I documenti che otteniamo dal fabbricante del dispositivoChicago Electric 94882 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Chicago Electric
- manuali per l’uso 94882
- schede prodotto Chicago Electric
- opuscoli
- o etichette energetiche Chicago Electric 94882
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Chicago Electric 94882.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Chicago Electric 94882, manuali di manutenzione, brevi manuali o manuali utente Chicago Electric 94882. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Chicago Electric 94882.

Manuale completo del dispositivo Chicago Electric 94882, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Chicago Electric 94882 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Chicago Electric 94882.

Il manuale per l’uso completo Chicago Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Chicago Electric 94882 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Chicago Electric 94882, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Chicago Electric 94882 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Chicago Electric 94882 - che ci dovrebbe aiutare nei primi passi durante l'uso Chicago Electric 94882
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Chicago Electric 94882
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Chicago Electric 94882 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Chicago Electric 94882?

Utilizza il modulo sottostante

Se non hai risolto il problema con Chicago Electric 94882 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Chicago Electric 94882 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)