Manuale per l’uso Empire Comfort Systems VFSV-30-3

24 pagine 1.36 mb
Scarica

Vai alla pagina of 24

Summary
  • Empire Comfort Systems VFSV-30-3 - page 1

    Page 1 18954-0-0705 W ARNINGS If the information in this manual is not followed exa ctl y , a fi re or exp los ion may resu lt c aus ing pro p - erty damage, personal injury or loss of life. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS • Do no ...

  • Empire Comfort Systems VFSV-30-3 - page 2

    Page 2 18954-0-0705 Section Page Important Safety Information .........................................................................................................................3 Safety Information for Users of LP Gas ..........................................................................................................4 Introduction ..... ...

  • Empire Comfort Systems VFSV-30-3 - page 3

    Page 3 18954-0-0705 W ARNING When use d without adeq uate combustion and ventilatio n air , heater may give off CARBON MONOXIDE, an odorless, poisonous gas. Do not insta ll hea ter until all nece ssa ry pro visi ons are made for com bus tio n and vent ila tio n air . Cons ult the wri tten in str uct ion s provided with the heater for information co ...

  • Empire Comfort Systems VFSV-30-3 - page 4

    Page 4 18954-0-0705 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area ...

  • Empire Comfort Systems VFSV-30-3 - page 5

    Page 5 18954-0-0705 Attention: During initial use of log you will detect an odor as the log is cured. Notice: During initial firing of this unit, its paint will bake out, and smoke will occur . T o prevent triggering of smoke alarms, ventilate the room in which the unit is installed. W ARNING: This appliance is for installation only in a solid-fue ...

  • Empire Comfort Systems VFSV-30-3 - page 6

    Page 6 18954-0-0705 This is an unvented gas-fired heater . It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids. Unven ted gas heater s are a supple mental zone ...

  • Empire Comfort Systems VFSV-30-3 - page 7

    Page 7 18954-0-0705 PROVISIONS FOR ADEQUA TE COMBUSTION & VENTILA TION AIR Minimum Dimensions For Solid Fuel Burning Fireplaces UL127 Factory Built Fireplaces (Figure 2) Model A B C D VFSV -16 18" 1 1 1/2" 24" 18" VFSR-16 18" 1 1 1/2" 24" 18" VFSV -18 17" 14" 28" 17" VFSR-18 17" 1 ...

  • Empire Comfort Systems VFSV-30-3 - page 8

    Page 8 18954-0-0705 Sidewall & Ceiling Clearances (Figure 3) Figure 3 The sides of the fireplace opening must be 6" from any combustible wall. The ceiling must be at least 36" (for the 16" log) and 41" (for 18", 24" and 30" logs) from the fireplace opening. Mantel Clearances W ithout Hood (Figure 4) Y ou mus ...

  • Empire Comfort Systems VFSV-30-3 - page 9

    Page 9 18954-0-0705 FIREPLACE PREP ARA TION • T urn off gas supply to fireplace or firebox. • Have the firep lace floor and chimn ey profes sion ally clea ned to remove ashes, soot, creosote or other obstructions. Have this cleaning performed annually after installation. • Seal any fresh air vents or ash clean-out doors located on floor ...

  • Empire Comfort Systems VFSV-30-3 - page 10

    Page 10 18954-0-0705 INST ALLING AS A VENTED APPLIANCE Notice (Damper Clamp Installation) When installing your log set as a vented installation the damper clamp must be used. When installing your log set as a vent-free installation the damper clamp can be used to eliminate the potential for odors when burn- ing the logs for the first time. Install ...

  • Empire Comfort Systems VFSV-30-3 - page 11

    Page 1 1 18954-0-0705 GAS SUPPL Y Check all local codes for requirements, especially for the size and type of gas supply line required. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe T ubing, T ype L Inside Diameter Outside Diameter Nat. L.P . Nat. L.P . 0-10' 1/2" 3/8" 1/2" 3/8" 0-3.048m 12.7mm 9.5mm 12.7mm 9.5 ...

  • Empire Comfort Systems VFSV-30-3 - page 12

    Page 12 18954-0-0705 Refer to Parts List, Page 20 to order loose material (rock wool). Placing Lava Rock in Front of Burner on Fireplace Floor Spread lava rocks on fireplace floor in front of the burner pan. The lava rocks are for decorative effect and are not required for fireplace operation. A TTENT ION : DO NOT PLACE LA V A ROCKS ON BURNER , ...

  • Empire Comfort Systems VFSV-30-3 - page 13

    Page 13 18954-0-0705 HI/LO REGULA TOR CONTROL KNOB PIEZO IGNITOR FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow the ...

  • Empire Comfort Systems VFSV-30-3 - page 14

    Page 14 18954-0-0705 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING ...

  • Empire Comfort Systems VFSV-30-3 - page 15

    Page 15 18954-0-0705 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information. 2. Make sure the manual shutoff valve is fully open. 3. This heater is equipped with an ignition device (piezo) which automatically lights the pilot. 4. Refer to Figure 15 for the location of the piezo ignitor and control knob. Push in gas control knob slightly and tur ...

  • Empire Comfort Systems VFSV-30-3 - page 16

    Page 16 18954-0-0705 Figures 16 and 19 show a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figures 17 and 20 show an incorrect pilot flame patte ...

  • Empire Comfort Systems VFSV-30-3 - page 17

    Page 17 18954-0-0705 Annual inspection and cleaning by your dealer or qualified service technician is recommended to prevent malfunction and/or sooting. T U R N O F F H E A T E R AN D A L L O W TO C O O L B E F O R E CLEANING. Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceram ...

  • Empire Comfort Systems VFSV-30-3 - page 18

    Page 18 18954-0-0705 WIRING Th erm ost ats ar e no t app rov ed on v en ted de cor at iv e app lia nce s. Label all wires prior to disconnection when servicing controls. W iring errors can cause improp er and dangerous opera tion. V erify proper operation after servicing. 16", 18", 24" and 30" Gas Logs (Millivolt) thermopile is ...

  • Empire Comfort Systems VFSV-30-3 - page 19

    Page 19 18954-0-0705 If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is low , contact your local gas supplier immediately . 1. When ignitor button is pressed, there is no spark at ODS/ pilot. a. Ignitor electrode positioned wrong - Replace pil ...

  • Empire Comfort Systems VFSV-30-3 - page 20

    Page 20 18954-0-0705 Attention: When ordering parts, it is very important that part number and description of part coincide. USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. P AR TS LIST Index No. Part Number Description COMMON P AR TS 1 15425 REAR LOG SUPPOR T (16) 1 15426 REAR LOG SUPPOR ...

  • Empire Comfort Systems VFSV-30-3 - page 21

    Page 21 18954-0-0705 P AR TS VIEW Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number . When ordering parts, first obtain the Mo ...

  • Empire Comfort Systems VFSV-30-3 - page 22

    Page 22 18954-0-0705 SER VICE NOTES ...

  • Empire Comfort Systems VFSV-30-3 - page 23

    Page 23 18954-0-0705 SER VICE NOTES ...

  • Empire Comfort Systems VFSV-30-3 - page 24

    Page 24 18954-0-0705 Empire Comfort Systems, Inc. Nine Eighteen Freeburg A ve. Belleville, Illinois 62220-2623 PH: 618-233-7420 PH: 800-851-3153 F AX: 618-233-7097 F AX: 800-443-8648 E-MAIL: info@empirecomfort.com WEB SITE: www .empirecomfort.com ...

Fabbricante Empire Comfort Systems Categoria Fan

I documenti che otteniamo dal fabbricante del dispositivoEmpire Comfort Systems VFSV-30-3 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Empire Comfort Systems
- manuali per l’uso VFSV-30-3
- schede prodotto Empire Comfort Systems
- opuscoli
- o etichette energetiche Empire Comfort Systems VFSV-30-3
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Empire Comfort Systems VFSV-30-3.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Empire Comfort Systems VFSV-30-3, manuali di manutenzione, brevi manuali o manuali utente Empire Comfort Systems VFSV-30-3. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Empire Comfort Systems VFSV-30-3.

Manuale completo del dispositivo Empire Comfort Systems VFSV-30-3, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Empire Comfort Systems VFSV-30-3 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Empire Comfort Systems VFSV-30-3.

Il manuale per l’uso completo Empire Comfort Systems, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Empire Comfort Systems VFSV-30-3 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Empire Comfort Systems VFSV-30-3, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Empire Comfort Systems VFSV-30-3 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Empire Comfort Systems VFSV-30-3 - che ci dovrebbe aiutare nei primi passi durante l'uso Empire Comfort Systems VFSV-30-3
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Empire Comfort Systems VFSV-30-3
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Empire Comfort Systems VFSV-30-3 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Empire Comfort Systems VFSV-30-3?

Utilizza il modulo sottostante

Se non hai risolto il problema con Empire Comfort Systems VFSV-30-3 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Empire Comfort Systems VFSV-30-3 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)