Manuale per l’uso Milan Technology MIL-S3570

23 pagine 1.04 mb
Scarica

Vai alla pagina of 23

Summary
  • Milan Technology MIL-S3570 - page 1

    MIL-S3570 24-Port Fast Ethernet Switch with Gigabit Uplinks INS TALLATION GUIDE TECHNOLOGY ...

  • Milan Technology MIL-S3570 - page 2

    Regulatory Approval - FCC Class A - UL 1950 - CSA C22.2 No. 950 - EN60950 - CE - EN55022 Class A - EN55024 Canadian EMI Notice This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouille ...

  • Milan Technology MIL-S3570 - page 3

    Table of Contents 1. Introduction 1 1.1 Features 2 1.2 Specifications 3 2. Installing the Switch 4 2.1 Packing List 4 2.2 Panels 4 2.3 Mounting the Switches 5 3. Making Network Connections 6 3.1 Network Switched Ports 6 3.2 10/100BASE-TX Fast Ethernet Ports 7 3.3 Gigabit Ethernet Slots 9 3.4 Making Trunk Connections 11 3.5 Virtual LAN (VLAN) 13 4. ...

  • Milan Technology MIL-S3570 - page 4

    1. Introduction Driven by recent advances in desktop computing technology, today’s network applications have increased in speed, power and the ability to process information. To meet the demands o f these more bandwidth- intensive applications, this switch device provides significant increase in performance for your Ethernet and Fast Ethernet net ...

  • Milan Technology MIL-S3570 - page 5

    1.1 Features Designed for resolving congestion problems caused by bandwidth-hungry devices and bandwidth-intensive applications as well as a high number o f users, the switches not only adhere to the IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX, and IEEE 802.3z 1000BASE-X standards, but also feature: • High port-count o f 10/100BASE-TX auto-negoti ...

  • Milan Technology MIL-S3570 - page 6

    1.2 Specifications Standard IEEE 802.3 10BASE-T, IEEE 802.3u 100BASE-TX IEEE 802.3z 1000BASE-X IEEE 802.3ad Port trunking IEEE 802.3x Full duplex flow control IEEE 802.1D Spanning tree IEEE 802.1Q Tagged VLAN IEEE 802.1P/Q GARP/GVRP Network ports 24 10/100BASE-TX switched ports 2 Gigabit switched slots for optional Gigabit module Console port 1 DB9 ...

  • Milan Technology MIL-S3570 - page 7

    2. Installing the Switch The switch is designed to operate in workgroup environments without a complicated configuration procedure. It also features an auto-select 100-240 V , 50/60Hz power supply unit, which works in most countries around the world. Before connecting the supplied power cord into the switch, check to see that the cord voltage and c ...

  • Milan Technology MIL-S3570 - page 8

    2.3 Mounting the Switches Desktop Mounting The switches can be placed on a desktop as a stand-alone unit. Allow enough ventilation space between the switch and the objects around it. Desktop Mounting Rack Mounting For mounting the switch into a 19-inch rack, a pair o f mounting brackets is included in the pack. Install Rack Mount Brackets Install t ...

  • Milan Technology MIL-S3570 - page 9

    3. Making Network Connections 3.1 Network Switched Ports The following figure illustrates the switched ports provided on the front panel. The switch comes with 24 10/100BASE-TX Fast Ethernet switched ports and two Gigabit Ethernet slots for Gigabit Ethernet modules. The following table lists the connectors provided on each network ports: Port # Sta ...

  • Milan Technology MIL-S3570 - page 10

    3.2 10/100BASE-TX Fast Ethernet Ports The switch can support connections to the following devices: • 10BASE-T or 10/100BASE-TX network cards • 10BASE-T hub ports • 100BASE-TX hub ports • 10/100BASE-TX dual speed hub ports • 10/100BASE-TX switch ports Auto-negotiation Capable The ports support auto-negotiation function when establishing a ...

  • Milan Technology MIL-S3570 - page 11

    UTP Cable Connections When making a connection to another device using straight-through UTP cable, make sure MDI-X to MDI connection rule is followed. The following figure illustrates the pin assignments o f a straight-through UTP and a crossover UTP cable: Straight-through and Crossover UTP Cable It is suggested to use straight-through UTP cables ...

  • Milan Technology MIL-S3570 - page 12

    3.3 Gigabit Ethernet Slots Each Gigabit Ethernet slot can accommodate one optional Gigabit Ethernet module for your Gigabit connection. The following modules are available for selection: Module Wavelength Connector type Fiber cable MIL-L3573SX 850 nm SC Multimode fiber MIL-L3574SX 850 nm MT-RJ Multimode fiber Module Outline The following figure ill ...

  • Milan Technology MIL-S3570 - page 13

    Auto-negotiation function The Gigabit Ethernet module operates on 1000M full-duplex mode. This function makes sure the system operates with maximum performance when it is connected to an auto-negotiation capable Gigabit Ethernet device. Duplex Mode Full duplex Fiber cable MM 50/125 micron meters, 62.5/125micron meters recommended Module Installatio ...

  • Milan Technology MIL-S3570 - page 14

    3.4 Making Trunk Connections Two switch units can be cascaded together through any regular switched data port on each unit when a port expansion is required. However, the transfer bandwidth between the two cascaded ports is limited to 200Mbps full duplex. To increase the bandwidth for the connection between two switch units, a trunking function is ...

  • Milan Technology MIL-S3570 - page 15

    The following figure illustrates a typical example of trunk connections between more than two switch units. Each trunk is a 2-port trunk. There are four trunks existing in this example. Each has 400Mbps bandwidth. The top switch is con - figured to have four trunks and is cascaded to four lower switch units. 12 ...

  • Milan Technology MIL-S3570 - page 16

    3.5 Virtual LAN (VLAN) Each port o f the switch unit connects to one individual LAN segment. There can be many Ethernet nodes located on each segment. The switch performs network data forwarding between different LAN segments. It allows Ethernet nodes located on different segments to communicate with each other. Basically, all Ethernet nodes are in ...

  • Milan Technology MIL-S3570 - page 17

    4. LED Indicators 4.1 LED Panels The switch provides comprehensive LED indicators for diagnosing and monitoring the operation o f the unit as illustrated below: 4.2 Interpretation Power LED: indicates the status o f the power supplied to the switch. Link/Act. LED: indicates the port cable link and traffic activity. Speed LED: indicates the connecti ...

  • Milan Technology MIL-S3570 - page 18

    5. Performing Network Management 5.1 Management Support The switch is featured with management functions and can be managed by using the following methods: · Direct console connection over an RS232 cable · Web browser software from Internet or Intranet over TCP/IP network · Telnet software over TCP/IP network · SNMP manager software over TCP/IP ...

  • Milan Technology MIL-S3570 - page 19

    5.2 Management objects The following table lists the management objects supported by the system: Login Basic Management Activities • General Management Configuration - system parameters • LAN Port Configuration - speed, link type, duplex, flow control • Console Port Configuration - console baud rate, flow control, modem control Advanced Manag ...

  • Milan Technology MIL-S3570 - page 20

    5.3 Setting IP Address Before performing any management operation over network, the most important thing is to learn the detailed information about the TCP/IP network where the managed unit is located. The information includes the network address, subnet mask, broadcast I P , IP o f the default router. The second thing is to assign an IP address to ...

  • Milan Technology MIL-S3570 - page 21

    5.4 Web Management Use any web browser with J AV A script support like Netscape Communicator 4.x or Microsoft Internet Explorer 4.0 or later on any platform. Connect to the managed unit using the IP address as URL address. http://xxx.xxx.xxx.xxx Refer to the operation manual provided in the supplied CD-ROM for the details. User name and password is ...

  • Milan Technology MIL-S3570 - page 22

    Contact the MiLAN web site for available software version. 5.8 Support This guide covers the basic information about the management functions supported by the managed switch. The detailed operation guides for all management functions are available in the software operation manual in the supplied CD-ROM. However, more features may be included into f ...

  • Milan Technology MIL-S3570 - page 23

    TECHNOLOGY A Division of Digi International ...

Fabbricante Milan Technology Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoMilan Technology MIL-S3570 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Milan Technology
- manuali per l’uso MIL-S3570
- schede prodotto Milan Technology
- opuscoli
- o etichette energetiche Milan Technology MIL-S3570
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Milan Technology MIL-S3570.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Milan Technology MIL-S3570, manuali di manutenzione, brevi manuali o manuali utente Milan Technology MIL-S3570. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Milan Technology MIL-S3570.

Manuale completo del dispositivo Milan Technology MIL-S3570, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Milan Technology MIL-S3570 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Milan Technology MIL-S3570.

Il manuale per l’uso completo Milan Technology, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Milan Technology MIL-S3570 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Milan Technology MIL-S3570, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Milan Technology MIL-S3570 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Milan Technology MIL-S3570 - che ci dovrebbe aiutare nei primi passi durante l'uso Milan Technology MIL-S3570
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Milan Technology MIL-S3570
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Milan Technology MIL-S3570 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Milan Technology MIL-S3570?

Utilizza il modulo sottostante

Se non hai risolto il problema con Milan Technology MIL-S3570 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Milan Technology MIL-S3570 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine