Manuale per l’uso Haier AP602AKEAA

30 pagine 0.66 mb
Scarica

Vai alla pagina of 30

Summary
  • Haier AP602AKEAA - page 1

    Please read this operation manual before using the air conditioner . No.0010578212 Operation & Installation Manual CABINET TYPE AIR CONDITIONER Please keep this manual carefully and safely . AP482AKEAA AP602AKEAA SLEEP ON/OFF MODE FAN SET TEMP HUMI HEALTH TIMER TEMP+ TEMP- HEALTH ...

  • Haier AP602AKEAA - page 2

    Content Operation Cautions Parts Operation Operation hints Energy saving Maintenance T rouble shooting When problems occur Indoor & outdoor unit connection T ools necessary Installation procedures 5-12 13 14 17 20 1-2 3-4 15-16 18-19 21 22-26 Others 27 ...

  • Haier AP602AKEAA - page 3

    Cautions 1 Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The v ...

  • Haier AP602AKEAA - page 4

    2 The machine is adaptive in following situation 1. pplicable ambient temperature range: Cautions Cooling Heating Indoor outdoor Rated Maximum Minimum 27 32 18 19 23 14 35 43 10 24 26 6 20 27 15 14.5 -- -- 7 24 -7 6 18 -- DB C WB C DB C WB C Indoor outdoor DB C WB C DB C WB C 4. The wiring method should be in line with the local wiring standard. 5. ...

  • Haier AP602AKEAA - page 5

    Parts 3 1 2 3 4 I n d o o r u n i t Outlet grill Operation panel Inlet grill Air filter [inside the unit] 1 2 Outdoor unit Inlet grill Outlet grill Remote controller ON OFF TEMP HEALTH F AN MODE SLEEP SWING CLOCK TIMER SET LOCK LIGHT RESET HEAT 2 1 2 3 4 1 2 SLEEP ON/OFF MODE FAN SET TEMP HUMI HEALTH TIMER TEMP+ TEMP- HEALTH SLEEP ON/OFF MODE FAN S ...

  • Haier AP602AKEAA - page 6

    Manual Operation MODE CLOCK Used to set correct time. TIMER LIGHT Used to set temp.,temp. range:16 C~30 C SLEEP Used to select sleep mode HOUR Used to set clock and timer setting. RESET Used to reset the controller back to normal condition. LOCK Used to select TIMER ON, TIMER OFF , TIMER ON/OFF . Used to lock buttons and LCD display . Note: These m ...

  • Haier AP602AKEAA - page 7

    5 1 2 3 Operation Clock set Press CLOCK button, "AM"or "PM" flashes. Press or to set correct time. Each press will increase or decrease 1 min . If the button is kept pressed, time will change quickly . After time setting is confirmed, press SET , "AM" and "PM" stop flashing, while clock starts working. Remote ...

  • Haier AP602AKEAA - page 8

    LOW MID HIGH AUTO Remote controller Remote controller AUTO COOL DRY F AN HEA T Operation 2 Press MODE button. For each press, operation mode changes as follows: 4 Press F AN,For each press, operation mode changes as follows: Unit runs at the speed displayed on LCD. When fan speed is AUTO,it is changed automatically according to the indoor temperatu ...

  • Haier AP602AKEAA - page 9

    7 Operation Fan Operation 3. Adjust fan speed Press F AN button. At each press, fan speed changes as follows: Air conditioner will run at the selected fan speed. 4. Unit stop Press ON/OFF button to stop unit. Then select F AN About F AN mode When the air conditioner runs in F AN mode,it is not possible to select AUTO F AN or to set temperature. Man ...

  • Haier AP602AKEAA - page 10

    8 (Not availble in these units) (Not availble in these units) 2.Up & down air direction Press the up & down button once ,the LCD aiflow direction will display as follows: Cooling/Dehumification/airflow : The up& down flade will move according to the above conditions. Note:Pay more attention to not cut down the power supply because the f ...

  • Haier AP602AKEAA - page 11

    Sleep Function Before using this function, the clock must be set. Use of SLEEP function After the unit's start, set running mode and then press SLEEP button once to make the air conditioner have the previous-set sleep time (first power-on is "1h"). The sleep symbol will appear . Press time button / : you can choose the time in 1~8 ho ...

  • Haier AP602AKEAA - page 12

    T imer ON/OFF Function Set clock correctly before starting TIMER operation 1.Unit start After unit start, select your desired operation mode (operation mode will be displayed on LCD) 2.TIMER mode selection Press TIMER button on the remote controller to change TIMER mode. Every time the button is pressed, display of TIMER mode changes as follows: ON ...

  • Haier AP602AKEAA - page 13

    Manual Operation Remote controller 1 1 Operation T imer ON-OFF Function Set clock correctly before starting TIMER operation 1.Unit start After unit start, select your desired operation mode (operation mode will be displayed on LCD) 2.TIMER mode selection Press TIMER button on the remote controller to change TIMER mode. Every time the button is pres ...

  • Haier AP602AKEAA - page 14

    12 Operation Display function 1.Control panel display control: Press the LIGHT button ,the LCD will display according to the following sequence when press once : LCD bright Buzzer not act LCD bright Buzzer act LCD not bright Buzzer act 2.LCD color control: When the LCD bright ,the color will display according to the above standard color ,when two o ...

  • Haier AP602AKEAA - page 15

    Unit operation Protection devices inside the unit will activate to stop unit operation, when ambient temp. is extremely low or high. When unit is running under high humidity in cooling or dehumidifying mode, condensate might appear at outlet grill. 3-min delay protection Fan speed changes Unit will not restart until 3 min have elapsed for the prote ...

  • Haier AP602AKEAA - page 16

    14 Energy saving Keep proper room temp. T oo cold or too warm is no good to your health, and power consumption will be increased as well. Air filter should be periodically cleaned If air filter is clogged: It will cause poor cooling and heating efficiency , higher power consumption and even problem may occur . In cooling operation, water will flow ...

  • Haier AP602AKEAA - page 17

    15 Don't spray any paint or insecticide on the unit. Don't splash water directly on indoor unit. This will cause damage or even fire accident. This could be very dangerous Maintenance Disconnect power supply Don't touch it with wet hand Don't wash with hot water or solvent to clean the unit Pull it out from top as shown in Fig. ...

  • Haier AP602AKEAA - page 18

    16 Maintenance After season maintenance Before season maintenance Let the unit run in Fan mode for half a day in a fine weather to dry completely the unit inside. T urn off the unit and pull out power plug. There might be certain power consumption even if unit is stopped. Clean air filter and indoor unit, cover outdoor unit after cleaning. Check if ...

  • Haier AP602AKEAA - page 19

    17 T rouble shooting Followings are not problems Sound of water flowings are not problems. Sound of cracking is heard. Smells are generated. During operation, white fog or steam comes out of indoor unit. In cooling operation, unit switches to fan operation. Unit will not restart after stop. Won't start? No outlet air or fan speed can't be ...

  • Haier AP602AKEAA - page 20

    18 When problems occur Before asking services, please firstly check your unit according to following. If your unit still can't work properly after above mentioned checks, or following problems occur , please stop it immediately and contact your dealer . Fuses or circuit breakers often blow out. W ater comes out in cooling/dry operation. Operat ...

  • Haier AP602AKEAA - page 21

    19 When problems occur 2. Power supply 1. Errors display Room temp. sensor abnormal Indoor coil temp. sensor abnormal Air conditioner must use an exclusive line (over 30A) When installation air conditioner in a wet place, try to use a circuit breaker against current leakage. For installation in other places, use circuit breaker as far as possible. ...

  • Haier AP602AKEAA - page 22

    20 Indoor & outdoor unit connection ON/OFF MODE FAN TEMP+ TEMP- HEALTH pipe direction Over 10cm Over 10cm Over 10cm Over 10cm Over 10cm Over 15cm Over 100cm Over 60cm Right Left Rear Bottom SET HUMI TEMP HEALTH TIMER SLEEP ...

  • Haier AP602AKEAA - page 23

    21 T ools necessary T ools necessary Standard accessories 1. Screw driver 2. Hacksaw 3. 70mm dia. hole core drill 4. Spanner (dia. 22, 36mm) 5. Spanner (16, 18, 22, 36mm) 6. Pipe cutter 7. Flaring tool 8. Knife 9. Nipper 10. Gas leakage detector or soap water 1 1. Measuring tape 12. Reamer 13. Refrigerant oil Following parts shall be field supplied ...

  • Haier AP602AKEAA - page 24

    22 Installation procedures Display of whole unit Installation of outdoor unit 190 380 190 580 Installation dimension of outdoor unit (mm) T ry to bring the packed unit to the installation place. When it is inevitable to unpack the unit, be careful not to damage the unit. Wrap it with nylon etc. After unpacking, be sure to put it with the front side ...

  • Haier AP602AKEAA - page 25

    23 Installation procedures Installation of indoor unit Selection of installation place Place where it is easy to route drainage pipe and outdoor piping. Place away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evenly to every corner of the room. Place near power supply socket. Leave enough space ar ...

  • Haier AP602AKEAA - page 26

    24 Installation procedures 2. Piping connection of indoor unit Arrangement of piping and drainage pipe After opening inlet grill, you will see a control box as shown in the Fig. Remove the cover before wiring work. Cut away , with a hammer or a saw , the lid for piping according to piping direction. According to the piping method, connect the pipin ...

  • Haier AP602AKEAA - page 27

    25 Arrangement of drain hose Drain hose shall be placed in under place. There should be a slope when arrange drain hose. Avoid up and down waves in drain hose. Indoor unit Slope Good Up Down Bad If humidity is high, drain pipe( especially in room and indoor unit ) must be covered with insulation material. Installation procedures 3. Piping connectio ...

  • Haier AP602AKEAA - page 28

    26 Note: Electric wiring must be done by qualified person. Wiring of indoor unit Insert the cable from outside the wall hole where piping already exist. Pull it out from front. Loosen terminal screws and insert cable end fully into terminal block, then tighten it. Pull the cable gently to make sure it is tight. Replace cover after wiring. Wiring of ...

  • Haier AP602AKEAA - page 29

    27 Others 2.Installation inspection and test run: Please operate unit according to this Manual. Items to be checked during test run. Please made a " " in " " Are there any gas leakage? How is insulation at piping connection carried out? Are electric wires of indoor and outdoor unit firmly inserted into terminal block? Is electri ...

  • Haier AP602AKEAA - page 30

    HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266500, P .R.China Web Site: http://www .haier .com ...

Fabbricante Haier Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoHaier AP602AKEAA possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Haier
- manuali per l’uso AP602AKEAA
- schede prodotto Haier
- opuscoli
- o etichette energetiche Haier AP602AKEAA
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Haier AP602AKEAA.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Haier AP602AKEAA, manuali di manutenzione, brevi manuali o manuali utente Haier AP602AKEAA. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Haier AP602AKEAA.

Manuali per l’uso simili

Manuale completo del dispositivo Haier AP602AKEAA, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Haier AP602AKEAA dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Haier AP602AKEAA.

Il manuale per l’uso completo Haier, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Haier AP602AKEAA - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Haier AP602AKEAA, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Haier AP602AKEAA che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Haier AP602AKEAA - che ci dovrebbe aiutare nei primi passi durante l'uso Haier AP602AKEAA
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Haier AP602AKEAA
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Haier AP602AKEAA in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Haier AP602AKEAA?

Utilizza il modulo sottostante

Se non hai risolto il problema con Haier AP602AKEAA con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Haier AP602AKEAA è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)