Daikin 2AMX50G3V1B - page 1
INSTALLATION MANUAL R410A Split Series Models 2MXS40G2V1B 2MKS40G2V1B 2MXS40H2V1B 2MKS40H2V1B 2MXS40H3V1B 2MKS50G2V1B 2MXS50G2V1B 2MKS50H2V1B 2MXS50H2V1B 2MXS50H3V1B 2AMX40F2V1B 2AMX40G2V1B 2AMX40G3V1B 2AMX50F2V1B 2AMX50G2V1B 2AMX50G3V1B Deutsch Français Nederlands Español Italiano Ελληνικ Ü Portugues Р ó сс ê ий English Türkçe I ...
-
Daikin 2AMX50G3V1B - page 2
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan 3SB64417-5A 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B, 2AMX40G2V1B, 2AMX50G2V1B, 2AMX40F2V1B, 2AMX50F2V1B, 2MXS40G2V1B, 2MXS50G2V1B, 2MKS40G2V1B, 2MKS50G2V1B 2MXS40H2V1B, 2MXS50H2V1B, 2MKS40H2V1B, 2MKS50H2V1B D AIKIN INDUSTRIES, L TD. Noboru Murata Manager Quality C ...
-
Daikin 2AMX50G3V1B - page 3
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan D AIKIN INDUSTRIES, L TD. EN60335-2-40, DAIKIN.TCF .015 P6/07-2012 DEKRA Certification B.V . (NB0344) 74736-KRQ/EMC97-4957 3SB65451-10D Shinri Sada Manager Quality Control Depar tment 2MXS40H3V1B, 2MXS50H3V1B, 2AMX40G3V1B, 2AMX50G3V1B Machinery 2006/42/EC ** Electromagnetic ...
-
Daikin 2AMX50G3V1B - page 4
3SB65451-4.fm Page 2 Thursd ay, October 27, 2011 4:49 PM ...
-
Daikin 2AMX50G3V1B - page 5
1 ■ English Safety Precautions • The precautions descri bed herein are classified as W ARN ING and CAUTION. They both contain important informa - tion regarding safety . Be sure to observe all precau tions without fail. • Meaning of W ARNING and CAUTION no tices W ARN ING .... Failure to follow these instructions pr operly may result in perso ...
-
Daikin 2AMX50G3V1B - page 6
■ English 2 Accessories Accessories supplied wit h the outdoor unit: Precautions for Selecting the Location 1) Choose a place soli d enough to bear th e weight and vibratio n of the uni t, where the operation noi se will not be ampli fied. 2) Choose a location where the hot air discharged from the unit or the operation noi se, will not cause a nu ...
-
Daikin 2AMX50G3V1B - page 7
3 ■ English Indoor/Outdoor Unit Installation Drawings For installation of the indoor units, refer to the insta llation manual which was provided with the units. (The diagram shows a wall-mounted indoor unit.) CAUTION • Do not connect the embedded bran ch piping and the outdoor unit when only carrying out piping w ork without connecting the indo ...
-
Daikin 2AMX50G3V1B - page 8
■ English 4 Installation • Install the unit horizontally . • The unit may be installed directly on a concrete verandah or a solid place if drai nage is good. • If the vibration may possibly be transmitted to the bu ilding, use a vibration-pr oof rubbe r (field supply). 1. Connections (connection por t) Install the indoor unit according to t ...
-
Daikin 2AMX50G3V1B - page 9
5 ■ English Outdoor Unit Installation Guideline • Where a wall or other obstacle is in the path of outdoor unit’s inlet or outlet airflow , follow the instal lation guidelines be low . • For any of the below installation pattern s, the wall height on the exhaust side should be 120 0mm or less. Selecting a Location for Installation of the In ...
-
Daikin 2AMX50G3V1B - page 10
■ English 6 Refrigerant Piping W ork 1. Installing outdoor unit 1) When installing the outdoor unit, refer to “Precautions for Se lecting the Location” on page 2 and the “Indoor/Outdoor Unit Installation Drawings” on p age 3. 2) If drain work is ne cessary , follow the procedures below . 2. Drain work (only heat pump models) 1) Use the dr ...
-
Daikin 2AMX50G3V1B - page 11
7 ■ English Refrigerant Piping W ork 4. Purging air and ch ecking gas leakage WARNING • Do not mix any substance other tha n the specifie d refrigerant (R410A) into the refrigera tion cycle. • When refrigerant gas leaks occur , ventilate the room as soon and as much as possible. • R410A, as well as other refrigerants, should always be reco ...
-
Daikin 2AMX50G3V1B - page 12
■ English 8 5. Refilling the refrigerant Check the type of refrigerant to be used on the machine nameplate. Precautions when adding R410 A Fill from th e gas pipe i n liquid form. It is a mixed refrigerant, so adding it in gas form may cause the refrigerant composition to change, p reventing normal operatio n. 1) Before filling, check wheth er th ...
-
Daikin 2AMX50G3V1B - page 13
9 ■ English Refrigerant Piping W ork Precautions for Laying Refrigerant Piping • Cautions on pipe handling 1) Protect the open end of the pipe against du st and moisture. 2) All pipe bends should be as gentle as possible. Use a pipe bender for bending. • Selection of copper and heat insulat ion materials When using commercial copper pipes and ...
-
Daikin 2AMX50G3V1B - page 14
■ English 10 Pump Down Operation In order to protect the environment, be sure to pump down when relocating or disposing of the unit. 1) Remove the valve cap s on the liquid an d the gas stop valves at the pipes for rooms A and B. 2) Run the unit on forced cooling. (Refer to the below .) 3) After 5 to 10 minutes, close the liquid stop valves at th ...
-
Daikin 2AMX50G3V1B - page 15
11 ■ English Wir ing WARNING • Do not use tapped wire s, stranded wires ( CAUTION 1)), extension co rds, or starburst co nnections, as they may cau se over- heating, electrical shock, or fire. • Do not use locally purchased electrical parts inside the produc t. (Do not branch the power for the drain pump, etc., from the terminal block.) Doing ...
-
Daikin 2AMX50G3V1B - page 16
■ English 12 Maximum Power Input Limitation Setting WARNING Always shut off the power supply breaker before starting. • The Maximum Power Input Limitation needs to be set when the unit is installed. • This function limi ts the power input of the unit to 1700W . • It is recommended for locations with low-capaci ty circuit breakers. CAUTION T ...
-
Daikin 2AMX50G3V1B - page 17
13 ■ English ECONO Mode Prohibition Setting WARNING Always shut off the power supply breaker before starting. • This setting disables the inp ut control signal from the remote controller . • Use this setting when you wish to block receptio n of input controls (cooling/heating) from indoor unit remote co ntrollers. • Set as follows. 1) Remov ...
-
Daikin 2AMX50G3V1B - page 18
■ English 14 T rial Operation and T esting • Before starting the test run, measure the voltag e at the primary side of the safety breaker . • Check that all liquid and gas stop valves are fully open. • Check that pipi ng and wiring all match. 1. T rial operation and testing 1) T o test cooling, set for the lowest temp erature. T o test heat ...
-