Manuale per l’uso Enviro Meridian C-10135

38 pagine 3.02 mb
Scarica

Vai alla pagina of 38

Summary
  • Enviro Meridian C-10135 - page 1

    PELLET ST OVE MERIDIAN PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH Contact your building or fire officials about restrictions and installation inspection requirements in your area. SHERWOOD INDUSTRIES ...

  • Enviro Meridian C-10135 - page 2

    T able of Contents 2 Introduction..............................................................................................................3 P ellet Quality ..................................................................................................3 Rating Label Location.................................................................... ...

  • Enviro Meridian C-10135 - page 3

    PELLET QUALITY IS IMPORTANT, PLEASE READ YOUR ENVIRO PELLET STOVE HAS BEEN DESIGNED TO BURN WOOD PELLETS ONLY. DO NOT USE ANY OTHER TYPE OF FUEL, AS THIS WILL VOID ANY WARRANTIES STATED IN THIS MANUAL. CAUTION: It is important to select and use only pellets that are dry and free of dirt or any impurities such as high salt content. Dirty fuel will a ...

  • Enviro Meridian C-10135 - page 4

    Fuel : T his pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty fuel will adversely affect the operation and performance of the unit and may void the warranty . Check with your dealer for fuel r ecommendations. THE USE OF CORDWOOD IS PROHIBITED BY LAW. Soot: Operation of the stove with insufficient ...

  • Enviro Meridian C-10135 - page 5

    Glass: Do not abuse the glass by striking or slamming the door . Do not attempt to oper ate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO dealer . Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot. Flammable Liquids: Never use gasolin ...

  • Enviro Meridian C-10135 - page 6

    Y our pellet Stove has the following safety f eatures: A) The stove will shut off when the fir e goes out and the exhaust temperature drops below 120°F (49°C). B) The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F (93°C) the auger will automatically stop, and the stove will shut off when the exhaust t ...

  • Enviro Meridian C-10135 - page 7

    7 This stove can be placed into two different thermostat modes: HI / LOW OPERATION: If the unit has been placed in the HI / LOW mode. The unit will operate on the low setting when the thermostat is not calling for heat. When the thermostat calls for heat, the uni t will go to your selected setting which is displayed on the control boar d Heat Outpu ...

  • Enviro Meridian C-10135 - page 8

    8 Oper a ting Instructions S LIDER /D AMPER S ETTING : The slider damper is located behind the left cab side. The door must be open f or the cab side to be r emoved on all models. On freestanding model loosen the two T20 torx screws, one above and one below hinge, swing open left panel to access. On insert model remov e the two T20 torx screws on t ...

  • Enviro Meridian C-10135 - page 9

    PRE-BURN INSTRUCTIONS : The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper oper ation. Check the hopper for enough pellets to start the unit. DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN AJAR MANUAL MODE: To START: Press the ON / OFF Button. The stove will turn on. The S ystem Light will ...

  • Enviro Meridian C-10135 - page 10

    10 2-3 DA YS/WEEKL Y SEASON or 2 T ONS OF FUEL Burn Pot and Liner Exhaust V ent Ash Pan Fresh air Intake T ube Inside Firebox Blower Mechanisms Door Glass Heat exchanger tubes Heat exchanger tubes Behind firebox liners Ash pan and Door gaskets All Hinges Door Latch Post Season Clean-up TOOLS REQUIRED TO CLEAN UNIT T orx T20 Screwdriver , 5 / 16 ” ...

  • Enviro Meridian C-10135 - page 11

    HEAT EXCHANGER TUBES (weekly) Open the door and the rod is located under the unit top, in the center of the stove just behind the door (see figure to left). This handle is to be pushed in and out a few times (ONLY WHEN THE UNIT IS COLD) in order to clean away any fly ash that may have collected on the heat exchanger tubes. As diff erent t ypes of p ...

  • Enviro Meridian C-10135 - page 12

    1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, garage, or any unventilated space. Combustion air may be obtained from a ventilated cr awlspace. 3. Do not install the stove in a bedroom. 4. Y ou can vent the stove through an exterior wall behind the unit or connect it to an existing masonry or metal chimney (must ...

  • Enviro Meridian C-10135 - page 13

    13 Inst alla tion F REESTANDING D IMENSIONS : WIDTH: 24  inches (63.2 cm) HEIGHT: 32  inches (82.6 cm) DEPTH: 24  inches (63.2 cm)         Y our MERIDIAN pellet stove requires floor protection. The floor protection must be non-combustible, exten ...

  • Enviro Meridian C-10135 - page 14

    14 Inst alla tion I NSERT C LEARANCES TO C OMBUSTIBLES (I NSTALLED I N M ASONRY F IREPLACE ): The fireplace insert model includes a surround faceplate and a pedestal. When instal ling this unit, ensure that the pedestal is removed fr om the inside of the hopper and installed on the bottom of the unit. SIDE WALL 8 inches (20.3 cm) from the body of t ...

  • Enviro Meridian C-10135 - page 15

    1. Do not terminate the vent in any enclosed or semi-enclosed areas such as a carport, garage, at tic, crawlspace, narrow walkway , closely fenced area, under a sundeck or porch, or any location that can build up a concentration of fumes such as stairwells, cover ed breezeway , etc. 2. V ent surfaces can become hot enough to cause burns if touched ...

  • Enviro Meridian C-10135 - page 16

    Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes. When connecting to an outside fresh air source, do not use plastic, combustible pipe. Only 2” ID (inside diameter) steel, aluminum or copper pipe should be used. It is recommended, when you are installing a fresh air system, to keep the number of bends in ...

  • Enviro Meridian C-10135 - page 17

    17 The MERIDIAN can be vented through the wall using two different methods. Only use vent of (L or PL) type with an inside diameter of 3 or 4 inches (7 .6 or 10.1 cm) VENT INSTALLATION: INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces ...

  • Enviro Meridian C-10135 - page 18

    Inst alla tion T HROUGH W ALL W ITH V ERTICAL R ISE I NSTALLATIONS : Wall framing Wall thimble Termination cap Vent pipe Horizontal frame for thimble   Wall framing Wall thimble Termination cap Vertical section of vent pipe Horizontal frame for thimble Clean out tee 90 deg elbow   ...

  • Enviro Meridian C-10135 - page 19

    19 1. Choose a stove location that is ideal. See the section Deciding Where to Locate Y our P ellet Appliance. 2. Place the unit on the hearth pad (i f installed on a carpeted surface) and space the unit in a manner so when the pellet vent is installed vertically , it will be 3” (7 .6 cm) away from a combustible wall. 3. Locate the center of the ...

  • Enviro Meridian C-10135 - page 20

    1. Lock fireplace damper in the open position. 2. Install positive flue connector at the fireplace dampers. 3. Connect a T ee or a 90 ° degree elbow to the exhaust pipe. 4. Install flexible stainless steel liner or listed pellet vent to the top of the chimney . Inst alla tion H EARTH M OUNT I NSTALLATION :    ? ...

  • Enviro Meridian C-10135 - page 21

    The MERIDIAN can be equipped with an externally mounted exhaust blower (P ART #20-070). This optional kit will include all components necessary to install the exhaust blower on any external vertical w all surface. Choose a location for your stove that meets the requirements stated in this manual and allows installation with the least amount of inte ...

  • Enviro Meridian C-10135 - page 22

    22 Inst alla tion E XTERIOR M OUNTED E XHAUST B LOWER : TO SUPPLY POWER TO THE EXHAUST BLOWER: Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble, and attach to the pre-drilled hole in the left hand rear hopper pillar . Hook up to wires from the wiring harness for the exhaust blower . All electrical c ...

  • Enviro Meridian C-10135 - page 23

    Follow the previous pages for through wall installations. Ensure that vent pipe is properly secured to wall using w all straps. Maintain clear ances to combustibles on vent pipe as well as unit. Inst alla tion T HROUGH W ALL V ERTICAL I NSTALLATION :        ...

  • Enviro Meridian C-10135 - page 24

    24 Inst alla tion M ASONRY F IREPLACE I NSERT I NSTALLATION : The Fireplace insert model requires a surround faceplate and a pedestal. When installing this unit, ensure that the pedestal is removed from the inside of the hopper and installed on the bottom of the unit (see “Installation of Fireplace Insert P edestal and Leveling Legs” and “ As ...

  • Enviro Meridian C-10135 - page 25

    Thread hex nut onto the bolt till it is approximately 1” (2.5cm) from the bolt head, slide washer onto bolt. Thread the bolt into the square nut so length of the bolt shown is the approximately height needed for leveling. When the unit is up right and the bolts can be adjusted to the exact height required. T o lock the bolts at a height tighten t ...

  • Enviro Meridian C-10135 - page 26

    26 Inst alla tion A SSEMBLY AND I NSTALLATION OF I NSERT S URROUND P ANELS : T o assemble the surround panels, lay the panels face down on a soft flat surface and align the outer edges of the sides with the top panel. Using four T20 screws up through the side panels into the top (see top left figure).  I NSTALLATION AND R EMOVAL OF C ON ...

  • Enviro Meridian C-10135 - page 27

    27 Inst alla tion P LATED T RIM I NSTALLATION : TO AVOID PERSONAL INJURY DO NOT REMOVE OR REPLACE TRIMS WHEN PELLET STOVE IS HOT! KIT COMPONENTS: T OOLS REQUIRED: ●T20 screwdriver ● 11 / 32 ” socket REMOV AL OF SIDE TRIMS: When stove is off and cool, open the door . Remove the two screws on the right cab side (at top and bottom of front an ...

  • Enviro Meridian C-10135 - page 28

    TO AVOID PERSONAL INJURY DO NOT REMOVE OR REPLACE COVER WHEN PELLET STOVE IS HOT! TOOLS REQUIRED: ● 11 / 32 ” socket or wrench REMOV AL OF DOOR COVER: When stove is off and cool, open the door . Remo ve the four #8 hex nuts around the inside of the glass retainer shown in Figure 1. Remo ve door co ver from door by gently sliding the studs out o ...

  • Enviro Meridian C-10135 - page 29

    29 DO NOT: ● Service the stove wi th wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly . Only qualified technicians should deal with possible internal electrical failures. ● Do not remove f rom the firebox any screws without penetr ating oil lubrication. WHAT TO DO IF: The stove will not start. ...

  • Enviro Meridian C-10135 - page 30

    30 ü Check the Exhaust Blower voltage across the blower wires (>=114V on #5 setting and >= 82V on #1 setting). – Replace the Circuit Board if the V oltage reading is less than 82V . with a line voltage >115V ac. ü Check V acuum levels in the exhaust channel by bypassing the V acuum Switch, then remove the V acuum hose from V acuum Swit ...

  • Enviro Meridian C-10135 - page 31

    31 Auger light flashes but auger motor does not turn at all : ü If the Auger gear box does not turn but the motor ’ s armature does try to spin then the auger is jammed. – T ry to break apart jam by poking at the jam through the dr op tube. If this fails then empty the hopper and remove the Auger Cover **R emember to re-seal the cover after in ...

  • Enviro Meridian C-10135 - page 32

    32 W iring Diagr am ...

  • Enviro Meridian C-10135 - page 33

    33 P ar ts List Part Number Description 20-040 Control P anel Door 50-178 Circuit Board 115V 50-179 Circuit Board Decal - 115V 50-323 Control P anel T ouch Latch 50-330 Circuit Board Control P anel 50-473 Combustion/ Exhaust Blower - 115V 50-474 Stainless Steel Burn Pot Liner 50-683 Door Cover - P ainted 50-623 Door Cover - P ewter 50-624 Door Cove ...

  • Enviro Meridian C-10135 - page 34

    34 MERIDIAN Steel Parts based on Freestanding   Hopper lid handle 50-523 Freestanding back grill 50-675 Top trim Painted 50-671 Gold 50-672 Pewter 50-673 Antique copper 50-674 Freestanding hopper lid 50-676 Freestanding top front 50-677 Control panel touch latch 50-323 Control panel door 20-040 Control panel 50-330 ...

  • Enviro Meridian C-10135 - page 35

    35 P ar ts Diagr am - Inser t Steel MERIDIAN Steel Parts based on Insert   Top trim Painted 50-671 Gold 50-672 Pewter 50-673 Antique copper 50-674 Insert hopper lid 50-827 Insert top front 50-825 Insert cabinet side right 50-824 Insert cabinet side left 50-823 Insert ash pan 50-826 Hopper cover 50-828 Insert regular ...

  • Enviro Meridian C-10135 - page 36

    36 MERIDIAN COMPONENTS   200°F (93°C) manual reset high limit sensor EF-016 Convection blower - 115V EF-002 Circuit board - 115V 50-178 Auger EF-025 Brass auger bushing EF-065 Auger motor - 115V EF-001 Vacuum switch - 115V EF-017 Combustion/exhausr blower - 115V 50-473 Slider/damper rod EF-064 160°F (71°C) Fan t ...

  • Enviro Meridian C-10135 - page 37

    Sherwood Industries Ltd. gives a five year limited warrant y on all steel manufactured parts. A one-year warr anty is provided on all electrical components. The abo ve limited warranties are extended only to the original purchaser . There is no warr anty on the following parts: ● Fiberglass rope baskets ● refr actory material ● burn pot liner ...

  • Enviro Meridian C-10135 - page 38

    38 The following information must be r ecorded by the installer for warrant y purposes and future reference. NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE:___________________________________ NAME OF ...

Fabbricante Enviro Categoria Stove

I documenti che otteniamo dal fabbricante del dispositivoEnviro Meridian C-10135 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Enviro
- manuali per l’uso Meridian C-10135
- schede prodotto Enviro
- opuscoli
- o etichette energetiche Enviro Meridian C-10135
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Enviro Meridian C-10135.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Enviro Meridian C-10135, manuali di manutenzione, brevi manuali o manuali utente Enviro Meridian C-10135. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Enviro Meridian C-10135.

Manuali per l’uso simili

Manuale completo del dispositivo Enviro Meridian C-10135, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Enviro Meridian C-10135 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Enviro Meridian C-10135.

Il manuale per l’uso completo Enviro, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Enviro Meridian C-10135 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Enviro Meridian C-10135, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Enviro Meridian C-10135 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Enviro Meridian C-10135 - che ci dovrebbe aiutare nei primi passi durante l'uso Enviro Meridian C-10135
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Enviro Meridian C-10135
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Enviro Meridian C-10135 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Enviro Meridian C-10135?

Utilizza il modulo sottostante

Se non hai risolto il problema con Enviro Meridian C-10135 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Enviro Meridian C-10135 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)