Manuale per l’uso Vermont Casting 647 BFC

24 pagine 1.06 mb
Scarica

Vai alla pagina of 24

Summary
  • Vermont Casting 647 BFC - page 1

    647 BFC cover 8/18/00 djt BFC Balance Flue (Closed Combustion) Heat-Circulating Fireplace Model: BFC36 For use in the U.S. / Canada Underwriter ’s Laboratories Report No. MH6018 DO NOT DISCARD THIS MANUAL: Retain for future use. 7412647 8/05 Rev . 10 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts ...

  • Vermont Casting 647 BFC - page 2

    2 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Safety Information Please Read This Manual Before Installing and Using Fireplace IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instruc- tions may result in a possible fire hazard and will void the warranty . Description The BFC ...

  • Vermont Casting 647 BFC - page 3

    3 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 BFC36 Balanced Flue Heat-Circulating Fireplace Fig. 1 BFC36 specifications and framing.  " (16mm)  " (13mm)  " 32  " (829mm) 41  " (1064mm)  " (16mm)  " (49mm)  " (914mm) ? ...

  • Vermont Casting 647 BFC - page 4

    4 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 FP554a BFC Fireplace and chase parts identification circulating model 8/21/00 djt T ermination Cap Storm Collar Pan Flashing Draftstop Standoff Surround T rim Ledge Standoff Glass Door Romex Pigtail Gas Line Access Knock - out (Each Side) Air Inlet Basket Grate Bottom Grille Metal Safety Strip ...

  • Vermont Casting 647 BFC - page 5

    5 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 D Rise B G H B Offset C E 6 FT . G H A Hearth Floor Chimney Sectio n CHIMNEY FLUE EXI T Elbow FP269 MBUF 5/16/96 rev . 5/2 5 TCS8A Support Example 1 Example 2 Example 3 Chimney Requirements - Offset Installations Notes: G + H cannot exceed 20 feet. Air Space Clearances: = 2” Min. to Combu ...

  • Vermont Casting 647 BFC - page 6

    6 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Planning Information Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only be mounted on the following sur- f ...

  • Vermont Casting 647 BFC - page 7

    7 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30’ (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30’ (9m). Locate chimney supports at ceiling holes or other structural framing at 30’ (9m) hei ...

  • Vermont Casting 647 BFC - page 8

    8 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 FPC555a Platform insulation BFC model 8/21/00 djt Hard Flat Surface Insulation Platform FPC555a Fig. 7 Insulating between platform and fireplace. Framing Framing can be constructed before or after the fireplace is set in place, however , most installers build the frame before setting the fi ...

  • Vermont Casting 647 BFC - page 9

    9 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Offset Installation In order to clear an obstruction, it may be necessary to offset chimney from vertical. This is accomplished by using elbows. Use the 30° Offset Elbow table on Page 5 to determine proper offset and parts required. Each offset requires two (2) elbows. The second elbow is equ ...

  • Vermont Casting 647 BFC - page 10

    10 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 ¹⁄₂ ” (38mm), al- lowing the remainder to extend in front of firebox. Over- lap strips at least 1/2? ...

  • Vermont Casting 647 BFC - page 11

    1 1 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 14. When you get a good lock, you will hear the pipe clearly snap together . Once sections are snap-locked in place, it is extremely dif? ...

  • Vermont Casting 647 BFC - page 12

    12 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Firestop spacers are not available for , nor are they required on vertical walls. DO NOT put any sealant around the area where the outer pipe slides through the firestop spacer . If you seal this area, it may cause a fire hazard. Canadian Requirements for Insulation Shield In Canada, an att ...

  • Vermont Casting 647 BFC - page 13

    13 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 FRONT VIEW SIDE VIEW Air Space Clearances FPC559a BFC AIR SP ACES circulating models 8/21/00 djt Standoff Combustible framing material MUST NOT penetrate AIR SP ACE (shaded areas). 2” ¹⁄₂ ” air space to sides Firestop 1” Air Space to Back ¹⁄₂ ” Air Space to Sides 0” Cleara ...

  • Vermont Casting 647 BFC - page 14

    14 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 MA81 rev. 8/5/97 1 ¹⁄₂ " Ref. Combustible materials are permitted within a shaded area shown in Figure 23 titled Minimum W all Clearances. * ** MA81 Fig. 20 Combustible mantel clearances. * 12” from top of grille opening. ** 6” from top of grille opening. Face Plate FP531b mante ...

  • Vermont Casting 647 BFC - page 15

    15 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Side W all Protection Adjacent combustible side walls that are within mini- mum dimensions shown in Figure 24 of the fireplace opening must be protected with CFM Corporation W all Shield Model SP40 or a specifically built wall shield described in Figure 18. The special wall shield design de ...

  • Vermont Casting 647 BFC - page 16

    16 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 W ARNING: Hearth extension must be installed in accordance with Figure 23 and must not cover the bottom front opening of the circulating model. Alternate noncombustible materials may be used pro- viding the (total) thermal resistance (Rt value) of the al- ternate material employed is greater ...

  • Vermont Casting 647 BFC - page 17

    17 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 KT108b BFC Correct door position 8/23/00 djt Correct Wrong Fig. 25 Correct door position. KT108b Installing Line for Gas Logs CFM Specialty Home Products fireplaces are designed to accept a 1/2” (13mm) gas line for installation of an approved gas appliance. (CFM Specialty Home Pro ...

  • Vermont Casting 647 BFC - page 18

    18 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 647 BFC parts 8/24/00 djt 1 2 3 5 6 7 8 9 10 1 1 12 13 14 16 15 19 18 17 � 24 25, 26 20 21, 22, 23 27 27 CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. BFC Balanced ...

  • Vermont Casting 647 BFC - page 19

    19 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 BFC Balanced Flue Fireplace (continued) 25. Stud 3/8-16 x 1 ⁵⁄₈ ” 20009776 26. Nut Hex Jam 3/8-16 T oplk 1203290 27. Black Fall Away Handle 20006382 Ref. Description BFC36 ...

  • Vermont Casting 647 BFC - page 20

    20 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 The following accessories for this appliance are available from your local V ermont Castings, Majestic Products distributor . Should you need additional information beyond what your distributor can furnish, contact: CFM Specialty Home Products, 410 Admiral Blvd., Mississauga, Ontario, Canada ...

  • Vermont Casting 647 BFC - page 21

    21 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 Chimney Components Component Description Model Number Chimney Support Used to support chimney for each of TCS8A 30’ vertical height and 6’ of angled chimney run (8” flue) Firestop Required at each floor level and attic on FS2A (8” straight flue) multi-story installation FS6A (8” ...

  • Vermont Casting 647 BFC - page 22

    22 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 ...

  • Vermont Casting 647 BFC - page 23

    23 BFC36 Balance Flue Heat-Circulating Fireplace 7412647 LIMITED W ARRANTY & 30 YEAR PROTECTION PLAN For V ermont Castings, Majestic Products PRE-ENGINEERED Fireplace Systems CFM Specialty Home Products warrants its Pre-Engineered Fireplace (“Fireplace”) and the CFM Specialty Home Products-supplied firegrate, glass doors, outside air syste ...

  • Vermont Casting 647 BFC - page 24

    410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com CFM Specialty Home Products ...

Fabbricante Vermont Casting Categoria Indoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoVermont Casting 647 BFC possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Vermont Casting
- manuali per l’uso 647 BFC
- schede prodotto Vermont Casting
- opuscoli
- o etichette energetiche Vermont Casting 647 BFC
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Vermont Casting 647 BFC.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Vermont Casting 647 BFC, manuali di manutenzione, brevi manuali o manuali utente Vermont Casting 647 BFC. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Vermont Casting 647 BFC.

Manuali per l’uso simili

Manuale completo del dispositivo Vermont Casting 647 BFC, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Vermont Casting 647 BFC dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Vermont Casting 647 BFC.

Il manuale per l’uso completo Vermont Casting, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Vermont Casting 647 BFC - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Vermont Casting 647 BFC, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Vermont Casting 647 BFC che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Vermont Casting 647 BFC - che ci dovrebbe aiutare nei primi passi durante l'uso Vermont Casting 647 BFC
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Vermont Casting 647 BFC
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Vermont Casting 647 BFC in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Vermont Casting 647 BFC?

Utilizza il modulo sottostante

Se non hai risolto il problema con Vermont Casting 647 BFC con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Vermont Casting 647 BFC è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)