  • DCS DCS-VH-30HS - page 1

    THE PROFESSIONAL VENT HOODS Use and Installation Guide Models:  DCS-VH-48HS  DCS-VH-48S  DCS-VH12-36HS  DCS-VH12-36S  DCS-VH-36HS  DCS-VH-36S  DCS-VH-30HS  DCS-VH-30S Dyn a m i c C o o k i n g Sy s t e m s, In c. ...

  • DCS DCS-VH-30HS - page 2

    A M e ss a ge T o Ou r C u s t o m e r s 1 Thank you for selecting this Dynamic Cooking Systems Pr ofessional V ent Hood. Because of its unique featur es , we have developed this Use and Installation Guide. It contains valuable information on how to pr operly operate and maintain your new V ent Hood for years of safe and enjo yable cooking. T o hel ...

  • DCS DCS-VH-30HS - page 3

    T ab le O f Content s 2 INTRODUCTION: The Dynamic Cooking Systems V ent Hood Models ha ve been designed with the ultimate in household conv enience in mind. Features include High Ca pacity , V ariable Speed Blow er , Commer cial Style dishwasher -safe filters, Easy-to-Clean inside liner , and Illuminating Halogen Lighting, all packaged in a stylish ...

  • DCS DCS-VH-30HS - page 4

    S af ety P ractice s & P recaution s 3 W ARNING- T o reduce the risk of a range top grease f ire: A) Nev er leav e surface units unattended at high settings. Boilovers cause smoking and gr easy spillov ers that may ignite. Heat oil slowly on lo w or medium settings. B) Alwa ys turn hood “ON” when cooking at high heat or when cooking flaming ...

  • DCS DCS-VH-30HS - page 5

    P lanning T he I ns tallation 4 BA CKDRAFT D AMPER: W e recommend that a backdraft damper be used in all V ent Hood installations. Cold weather installa- tions necessitate the use of a backdraft damper to minimize the flow of cold air into the r oom. A non- metallic thermal break should also be installed to minimize conduction of outside temperatur ...

  • DCS DCS-VH-30HS - page 6

    V ent Hood A s s emb ly 5 A B DCS Duct Cover (6" or 12" Height) Rough-In Kit junction box junction box Hood Inner Liner (Remove) ( 48" Model Liner Shown) Through junction box on rough-in kit, connect to house wiring to blower motor control panel Model DCS-IB12 Blower DCS VH 48 DCS VH12 36 Model DCS-IB6 Blower DCS VH 36 DCS VH 30 Roug ...

  • DCS DCS-VH-30HS - page 7

    6 V ent Hood I n s tallation ( with s of f it ) SITE PREP ARA TION This DCS Pr ofessional V ent Hood has been designed to accommodate installation into a 1) soffit structure (ceiling mount), or , for sites without a soffit structure. 2) directl y into the wall through holes pr ovided in the r ear panel of the vent hood (wall mount). When mounting t ...

  • DCS DCS-VH-30HS - page 8

    7 V ent Hood I n s tallation ( with s of f it ) INST ALL VENT HOOD INT O SOFFIT At this point in the installation pr ocess, the inner liner should be remo ved fr om the Hood and set aside (see-Pgs 5 & 6). With the liner set aside, there is clear access to the Soffit mounting holes and wall mounting holes in the rear panel of the unit. Once the ...

  • DCS DCS-VH-30HS - page 9

    8 V ent Hood I n s tallation ( without s of f it ) SITE PREP ARA TION: In cases where the installation site does not ha v e a soffit structure, the V ent Hood assembly ma y be secured dir ectly to the wall fr om the rear of the unit. NO TE- When installing the vent hood directly to the rear w all, an adequate structural w all suppor t (studs) must ...

  • DCS DCS-VH-30HS - page 10

    Fi n i sh i n g Th e In s t a l l a t i o n 9 T O FINISH THE INST ALLA TION Once the ventilation hood has been mounted in place it will be necessar y to install the electrical ser vice. All electrical work should be done by a qualified electrician and must conform to all local standards. Refer to the wiring diagrams on Pgs. 14-15, for pr oper hook- ...

  • DCS DCS-VH-30HS - page 11

    D uct I nfo rmation 10 GENERAL - When planning the path for ducting to the outside, keep in mind the following guidelines: - Minimize use of elbows and transitions in ductw ork as to maximize air flow to outside of building. An efficient airflow path contributes to the ov erall efficiency of the V ent Hood. - DCS recommends the use of smooth wall d ...

  • DCS DCS-VH-30HS - page 12

    D CS VH S e r i e s Sp e c i fi c a t i o n s 11 DCS VH SERIES HOODS Specify 48",36",30" 25" 18" 12" Specify 48",36",30" 12" 6",12" 3" 7-1/4" 3/4" 10-1/4" 12-1/4" 23-1/2" 10-1/4" 10-1/4" 7" 4-1/2" 3/4" 23-1/2" 10-1/4" 18-1/4& ...

  • DCS DCS-VH-30HS - page 13

    S e rvice 12 HO W T O OBT AIN SER VICE: Befor e you call for service: 1) Is the cir cuit break er tripped or the fuse blown? 2) Is there a po wer outage in the area? For war ranty ser vice, contact your local DCS authorized service agency . Provide him with the Model Number , Serial Number , and date of installation, and a brief description of the ...

  • DCS DCS-VH-30HS - page 14

    Wa r ranty 13 LENGTH OF W ARRANTY: One (1) Y ear Full parts and Labor Covers the entir e product Five (5) Y ear Limited war ranty covering the switches and motor . DCS WILL P A Y FOR All repair labor and parts found to be defectiv e due to materials or workmanship for one full y ear “IN HOME” warranty during the first y ear of ownership. This d ...

  • DCS DCS-VH-30HS - page 15

    Wi r i n g Di a g r a m DCS VH 48 14 CONNECTORS: WN-3 zinc brass SPEED CONTROL zinc brass (N) WHT (L1) BLK (GROUND) GRN WN-2 WN-1 WHT BLK LEFT LIGHT FAN SWITCH LEFT HEAT LIGHT MOTOR PLUG BLOWER MOTOR USED ON HS MODELS ONLY LEFT HEAT LIGHT SWITCH LIGHT SWITCH RIGHT HEAT LIGHT SWITCH RIGHT LIGHT RIGHT HEAT LIGHT USED ON HS MODELS ONLY 8 1 2 3 4 5 6 F ...

  • DCS DCS-VH-30HS - page 16

    Wi r i n g Di a g r a m DCS VH 30/36 15 zinc brass SPEED CONTROL WN-2 WN-1 LEFT LIGHT FAN SWITCH HEAT LIGHT USED ON HS MODELS ONLY HEAT LIGHT SWITCH LIGHT SWITCH RIGHT LIGHT 17 1 1a 1b 18 15 1a 1b 2b 10 11 4 3 1a 1b 15 9 10 13 1 19 14 (N) WHT (L1) BLK (GROUND) GRN 8 JUNCTION BOX 6 WN-3 2 CONNECTORS: 1 2 3 4 5 6 FEMALE 1 2 3 4 5 6 MALE BLOWER MOTOR ...

  • DCS DCS-VH-30HS - page 17

    No t e s 16 ...

  • DCS DCS-VH-30HS - page 18

    Part No. 10607r4 Litho in USA 04/2001 As product impr ovement is an ong o- ing process at DCS, we reserve the right to change specifications or design without notice. 5800 Skylab Road, Huntington Beach, C A 92647 T el: (714) 372-7000 Fax: (714) 372-7001 Par ts/Customer Service (888) 281-5698 www .dcsappliances.com ...

Fabbricante DCS Categoria Ventilation Hood

I documenti che otteniamo dal fabbricante del dispositivoDCS DCS-VH-30HS possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici DCS
- manuali per l’uso -VH-30HS
- schede prodotto DCS
- opuscoli
- o etichette energetiche DCS DCS-VH-30HS
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso DCS DCS-VH-30HS.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione DCS DCS-VH-30HS, manuali di manutenzione, brevi manuali o manuali utente DCS DCS-VH-30HS. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto DCS DCS-VH-30HS.

Manuali per l’uso simili

Manuale completo del dispositivo DCS DCS-VH-30HS, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare DCS DCS-VH-30HS dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti DCS DCS-VH-30HS.

Il manuale per l’uso completo DCS, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale DCS DCS-VH-30HS - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice DCS DCS-VH-30HS, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per DCS DCS-VH-30HS che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo DCS DCS-VH-30HS - che ci dovrebbe aiutare nei primi passi durante l'uso DCS DCS-VH-30HS
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del DCS DCS-VH-30HS
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio DCS DCS-VH-30HS in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su DCS DCS-VH-30HS?

Utilizza il modulo sottostante

Se non hai risolto il problema con DCS DCS-VH-30HS con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con DCS DCS-VH-30HS è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)