  • York H*RE024 - page 1

    036-21315-001 Re v . A (0502) FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TECHNICAL GUIDE SPLIT -SYSTEM AIR CONDITIONERS 14 SEER MODELS: H*RE024 THRU 060 (2 THRU 5 NOMINAL TONS) Due to continuo us product impr ovement, specifica tions are subjec t to change without notice . Visit us on the web at www .yo rk.com for the most u ...

  • York H*RE024 - page 2

    036-21315-001 Rev. A (0502 ) 2 Unitary Products Group Physical and Electr ical Dat a MODEL H1RE024S06 H1RE030S06 H1RE036S06 H2RE042S06 H2RE048S06 H2RE060S06 Unit Supply V oltage 208 / 230 - 1 – 60 Normal V oltage Range 1 187 to 252 Minimum Circuit Ampacity 12.1 14.9 18.1 17.8 20.6 31.8 Max Overcurrent Device Amps 2 20 20 25 30 35 50 Compressor T ...

  • York H*RE024 - page 3

    036-21315-001 Rev . A (0502) Unitary Products Group 3 - = Not applicable COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL 1 MODEL COOLING MODEL ELECTRIC 2 HEA T KW W RA TED CFM NET MBH SEER W/O TXV SEER + TXV 3 EER TOT AL SENS. 1 PH 14 SEER AC WITH N-AH / G2FD H1RE024S06 N1AHB0806 2,5,8,10 17 G2F D036S17 800 25.2 18.1 - 14.00 ...

  • York H*RE024 - page 4

    036-21315-001 Rev. A (0502 ) 4 Unitary Products Group COOLING CAP ACITY - Upflow , Downflow , & Horizont al Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER + TXV W/O TDR SEER + TXV 1 + TDR* EER TOT AL S EN S. H1RE024S06 700 900 14 G1F A036S1 4 800 25.0 18.0 13.85 - 12.30 17,21 G1F A036S ...

  • York H*RE024 - page 5

    036-21315-001 Rev . A (0502) Unitary Products Group 5 * Requires a 2FD Blower Time Delay unless a standard furnace is equipped with one. ** Refer to Quick Selection Chart for specific furnace match-up. H2RE060S06 1650 2150 21,24 G1F A060S21,24 1 900 53.5 37.1 - 13.25 12.00 24 G2FD060S24 1 900 53.5 37.1 - 13.25 12.00 24 G2FD061H24 2050 54.5 39.1 - 1 ...

  • York H*RE024 - page 6

    036-21315-001 Rev. A (0502 ) 6 Unitary Products Group 1. For condensing unit only . Does not include ef fe ct of evaporator motor power or heat. 2. Performance based on 1 5° superheat and 1 5° sub-cooling at condensing unit. a. Increa se capacit y 1% for e ach 2° in crease in sub-cool ing. b. Decrease capacity 1% for eac h 2° decrease in sub-co ...

  • York H*RE024 - page 7

    036-21315-001 Rev . A (0502) Unitary Products Group 7 TYPICAL INST ALLA TION TYPICAL FIELD WIRING MINIMUM 18” SERVICE ACCESS CLEARANCE ON ONE SIDE 60” OVERHEAD CLEARANCE 10” CLEARANCE COIL AREA WEA THERPROOF DISCONNECT SWITCH THERMOST A T TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING TO INDOOR COIL SEAL OPENIN ...

  • York H*RE024 - page 8

    036-21315-001 Rev. A (0502 ) 8 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H1RE024S06 INDOOR COIL MODEL NO. F2RP/F2FP036 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1 100 1250 1350 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York H*RE024 - page 9

    036-21315-001 Rev . A (0502) Unitary Products Group 9 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H1RE030S06 INDOOR COIL MODEL NO. G1UA048S21, 24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 800 1000 1200 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 6 ...

  • York H*RE024 - page 10

    036-21315-001 Rev. A (0502 ) 10 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H1RE036S06 INDOOR COIL MODEL NO. G1UA048S21, 24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1000 1200 1400 ID DB 85 80 70 85 80 70 85 80 70 ID WB 72 67 57 72 67 57 72 67 ...

  • York H*RE024 - page 11

    036-21315-001 Rev . A (0502) Unitary Products Group 11 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H2RE042S06 INDOOR COIL MODEL NO. G1UA060S21,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1300 1450 1550 ID DB 85 80 75 70 85 80 75 70 85 80 75 70 ID WB 72 67 62 57 72 ...

  • York H*RE024 - page 12

    036-21315-001 Rev. A (0502 ) 12 Unitary Products Group Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H2RE048S06 INDOOR COIL MODEL NO. G2FD060S24, G1UA060S21 ,24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1400 1600 1800 ID DB 85 80 70 85 80 70 85 80 70 ID WB 72 67 57 72 ...

  • York H*RE024 - page 13

    036-21315-001 Rev . A (0502) Unitary Products Group 13 Multipliers for determining th e performance with other indoor sections . COOLING PERFORMANCE DA T A AIR CONDITIONER MODEL NO. H2RE0 60S06 INDOOR COIL MODEL NO. G2FD060S24; G1UA060S21, 24 CONDENSER ENTERING AIR TEMPERA TURE ID CFM 1600 1800 2000 ID DB 85 80 70 85 80 70 85 80 70 ID WB 72 67 57 7 ...

  • York H*RE024 - page 14

    036-21315-001 Rev. A (0502 ) 14 Unitary Products Group MA TCHING INDOOR COMPONEN TS G1UA 1/2 CASED UPFLOW G1HD HORIZONT AL DUCT G2FD* MUL TI-POSITION (UPFLOW , HORIZONT AL AND DOWNFLOW) * Available with factory installed horizontal drain p an. ADD-ON COILS - FOR FURNACE APPLICA TIONS G1NA UNCASED UPFLOW G1F A FULL CASED UPFLOW AIR HANDLERS - FOR NO ...

  • York H*RE024 - page 15

    036-21315-001 Rev . A (0502) Unitary Products Group 15 NOTES ...

  • York H*RE024 - page 16

    Subject to change without notice. Printed in U.S.A. 036-21315-001 Rev. A (0502) Copyright © by York International Corp. 2002. All rights reserved. Supersedes: 550.50-TG1Y (600) Unitary 5005 Norman Product Y ork OK Group Drive 73069 ...

Fabbricante York Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoYork H*RE024 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici York
- manuali per l’uso H*RE024
- schede prodotto York
- opuscoli
- o etichette energetiche York H*RE024
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso York H*RE024.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione York H*RE024, manuali di manutenzione, brevi manuali o manuali utente York H*RE024. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto York H*RE024.

Manuali per l’uso simili

Manuale completo del dispositivo York H*RE024, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare York H*RE024 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti York H*RE024.

Il manuale per l’uso completo York, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale York H*RE024 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice York H*RE024, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per York H*RE024 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo York H*RE024 - che ci dovrebbe aiutare nei primi passi durante l'uso York H*RE024
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del York H*RE024
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio York H*RE024 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su York H*RE024?

Utilizza il modulo sottostante

Se non hai risolto il problema con York H*RE024 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con York H*RE024 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)