  • Casablanca Fan Company 59095 - page 1

    www .CasablancaF anC o.com 1.888.227.2178 T able of C ontents PA G E 5 30 inches 7 feet PA G E 2 What to Expect with Y our Installation Ladder PA G E 3 T ools Needed Canop y PA G E 7 PA G E 10 PA G E 6 Wiring Downrod Prepar ation PA G E 13 PA G E 4 Mounting Options Ceiling Br acket PA G E 12 W all C ontrol Congratulations on purchasing y our new Ca ...

  • Casablanca Fan Company 59095 - page 2

    www .CasablancaF anC o.com 1.888.227.2178 www .CasablancaF anC o.com 1.888.227.2178 www .CasablancaF anC o.com 1.888.227.2178 What t o Expec t with Y our Installation Know your wiring If you are unfamiliar with wiring , use a qualied electrician. Y ou may need a friend to help you . Check box to see fan weight Assess location 30 inches from blad ...

  • Casablanca Fan Company 59095 - page 3

    www .CasablancaF anC o.com 1.888.227.2178 3 M6011-01 • 10/30/14 • © Casablanca F an Company T ools Needed Ladder Po wer Drill (optional) 9/64” Drill Bit (optional) Screwdrivers Pliers Wire Strippers If mounting to a support structure, you will also need these tools . ...

  • Casablanca Fan Company 59095 - page 4

    www .CasablancaF anC o.com 1.888.227.2178 4 M6011-01 • 10/30/14 • © Casablanca F an Company If you ha ve an angled ceiling: 1. Y ou will need a longer do wnrod (sold separately) . 2. If your ceiling angle is greater than 34°, y ou will also need an Angled Mounting Kit (sold separately) . Guide T ouches BOTH Ceiling & Wa ll S I T U A T I O ...

  • Casablanca Fan Company 59095 - page 5

    www .CasablancaF anC o.com 1.888.227.2178 1.888.227.2178 www .CasablancaF anC o.com C eiling Bracket Refer to warning w .1 on pg. 2 T o av oid possible elec trical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location. F or angled ceilings, point openin ...

  • Casablanca Fan Company 59095 - page 6

    www .CasablancaF anC o.com 1.888.227.2178 Prepar ation 1.888.227.2178 www .CasablancaF anC o.com D I S C A R D K E E P ! Remove the shipping blocks fr om the motor . Sav e the screws . They will be needed for blade iron installation. Note: Some fans will hav e a shipping ring instead of shipping blocks. Please remove the ring and sa ve the screws. ...

  • Casablanca Fan Company 59095 - page 7

    www .CasablancaF anC o.com 1.888.227.2178 Downrod Slid e Slid e 1 2 3 4 5 6 7 8 9 10 Sold Separately Included Longer Downrod for angled ceilings or ceilings 10’ or higher Shorter Downrod for fans installed close to ceiling Standard Downrod for c eilings 8-10’ high Option 1 Option 2 Option 3 skip to next page If you need a diff erent downrod len ...

  • Casablanca Fan Company 59095 - page 8

    www .CasablancaF anC o.com 1.888.227.2178 KEEP! 8” 3/8” C U T & S T R I P (not to scale) Remove the pr e-installed setscrew so that the downrod can be inserted. Hand tighten the downrod (at least 4-5 full turns) until it stops. The wires can be cut, but leave at least 8” extending from the top of the downr od. Downrod (c ontinued) 8” 3/ ...

  • Casablanca Fan Company 59095 - page 9

    www .CasablancaF anC o.com 1.888.227.2178 9 M6011-01 • 10/30/14 • © Casablanca F an Company Downrod (c ontinued) DO NO T PICK THE F AN UP BY THE CANOPY OR WIRES. Place the downrod ball into the slot in the ceiling bracket. Put the wires and do wnrod through the canopy . Let the canopy sit loosely on t op of the fan. ...

  • Casablanca Fan Company 59095 - page 10

    www .CasablancaF anC o.com 1.888.227.2178 10 M6011-01 • 10/30/14 • © Casablanca F an Company Wiring T urn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet bo x. Re ...

  • Casablanca Fan Company 59095 - page 11

    www .CasablancaF anC o.com 1.888.227.2178 11 M6011-01 • 10/30/14 • © Casablanca F an Company F R O M R E C E I V E R white black blue white (common out) black (fan out) blue (light out) Using the wire connectors from the remote control har dware bag: • Connect the white wire from the receiver (marked “ common out ”) to the white wire fro ...

  • Casablanca Fan Company 59095 - page 12

    www .CasablancaF anC o.com 1.888.227.2178 12 M6011-01 • 10/30/14 • © Casablanca F an Company 1. Using a 9/64 drill bit, drill a hole in each scr ew cut-out on the wall control t emplate. 2. Using a hammer , tap a dr ywall anchor found in the wall contr ol hardware bag into each hole until the drywall anchor is ush with the wall. 1. Using a ...

  • Casablanca Fan Company 59095 - page 13

    www .CasablancaF anC o.com 1.888.227.2178 13 M6011-01 • 10/30/14 • © Casablanca F an Company Canop y No te: Fan style may vary . Lift the canopy into place so that the screw holes are aligned . Position the canop y so that, when lifted into place , the canopy ts into the hanging bracket as sho wn. Screw Holes Insert the two canopy screws fo ...

  • Casablanca Fan Company 59095 - page 14

    www .CasablancaF anC o.com 1.888.227.2178 M6011-01 • 10/30/14 • © Casablanca F an Company Blades 14 Remember the screws that you kept after removing the shipping blocks (page 6)? Y ou need them plus ve more from the hardwar e bag f or this step . Lightly attach the blade irons to the motor with screws found in the hardware bag , then secure ...

  • Casablanca Fan Company 59095 - page 15

    www .CasablancaF anC o.com 1.888.227.2178 S witch Housing Make sure the upper switch housing is securely attached to the mounting plate. F ailure to properly secure all 3 assembly screws could result in the switch housing xture falling. F eed the wire plug through the center hole of the upper switch housing , then wrap keyhole slots around the s ...

  • Casablanca Fan Company 59095 - page 16

    www .CasablancaF anC o.com 1.888.227.2178 S witch Housing (continued) Connect the plugs from the upper and lower switch housings . Mak e sure to line up the colored markings on the connectors. Lift the lower switch housing up until the holes line up with the screw holes in the upper switch housing . Install the three switch housing screws , found i ...

  • Casablanca Fan Company 59095 - page 17

    www .CasablancaF anC o.com 1.888.227.2178 M6011-01 • 10/30/14 • © Casablanca F an Company 17 Opera tion Quickly press the up or down arrow to turn the lights off and on. Hold the up or down arrow to dim or raise the light level. The reverse button changes the direction that the blades turn. The power button turns the fan off and on. ON T urn P ...

  • Casablanca Fan Company 59095 - page 18

    www .CasablancaF anC o.com 1.888.227.2178 Maintenanc e & Cleaning ON T urn P ower F or cleaning the fan, use sof t brushes or cloths to prevent scratching . Cleaning products may damage the nishes. The reverse button on the wall control changes the air ow direction. In warm weather , use (a) do wnward air ow pattern. In cold wea ther , ...

  • Casablanca Fan Company 59095 - page 19

    www .CasablancaF anC o.com 1.888.227.2178 19 M6011-01 • 10/30/14 • © Casablanca F an Company T roubleshooting Exc essive wobbling • Tighten all of the blade and blade iron screws until they are snug. • Use the provided balancing kit and instructions to balance the fan. Noisy Operation • Tighten the blade and blade iron screws until they ...

Fabbricante Casablanca Fan Company Categoria Fan

I documenti che otteniamo dal fabbricante del dispositivoCasablanca Fan Company 59095 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Casablanca Fan Company
- manuali per l’uso 59095
- schede prodotto Casablanca Fan Company
- opuscoli
- o etichette energetiche Casablanca Fan Company 59095
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Casablanca Fan Company 59095.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Casablanca Fan Company 59095, manuali di manutenzione, brevi manuali o manuali utente Casablanca Fan Company 59095. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Casablanca Fan Company 59095.

Manuale completo del dispositivo Casablanca Fan Company 59095, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Casablanca Fan Company 59095 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Casablanca Fan Company 59095.

Il manuale per l’uso completo Casablanca Fan Company, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Casablanca Fan Company 59095 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Casablanca Fan Company 59095, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Casablanca Fan Company 59095 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Casablanca Fan Company 59095 - che ci dovrebbe aiutare nei primi passi durante l'uso Casablanca Fan Company 59095
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Casablanca Fan Company 59095
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Casablanca Fan Company 59095 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Casablanca Fan Company 59095?

Utilizza il modulo sottostante

Se non hai risolto il problema con Casablanca Fan Company 59095 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Casablanca Fan Company 59095 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)