    1 W415-0514 / 05.30.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .continentalfireplaces.com • ask@continentalfire.com GAS-FIRED STOVES INST ALLA TION AND OPERA TION INSTRUCTIONS FOR: VENTED GAS FIREPLACE H ...

  • Continental CDVS500-N - page 2

    2 W415-0514 / 05.30.05 Pg 2 -4 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts 5 LOCA TION & CLEARANCES 6-11 DIRECT VENT SPECIFICS MODEL CDVS500 V ent Lengths/Air T erminal Locations Special Installation Example Offset Installation Example Wall & Ceiling Protection Horizontal V enting Installa ...

  • Continental CDVS500-N - page 3

    3 W415-0514 / 05.30.05 CONTINENTAL gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. CONTINENTAL products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and te ...

  • Continental CDVS500-N - page 4

    4 W415-0514 / 05.30.05 FOR YOUR SA TISF ACTION, THIS STOVE HAS BEEN TEST -FIRED TO ASSURE ITS OPERA TION AND QUAL- ITY! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 1 1 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural gas and 13 inches water column for propane. Mani ...

  • Continental CDVS500-N - page 5

    5 W415-0514 / 05.30.05 As long as clearance to combustibles is kept within the required distances, the most desirable and benefical location for a Continental stove is in the centre of a building, thereby allowing the most efficient use of the heat created. The loca- tion of windows, doors and the traffic flow in the room where the stove is to be l ...

  • Continental CDVS500-N - page 6

    6 W415-0514 / 05.30.05 Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or American Metal Amerivent venting components. For Simpson Dura-Vent, Selkirk Direct Temp and American Metal Amerivent, follow the installation procedure provided with the venting components. For vent systems that provide seals on the inner exhaust flue, only the ou ...

  • Continental CDVS500-N - page 7

    7 W415-0514 / 05.30.05 AIR TERMINAL INST ALLA TIONS * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * It is recommended to use a heat shield and to maximize the distance to vinyl clad sof fits . *** *** *** *** ** * The periscope GD-201 r equires a minimum 18 inc hes clear ance from an inside corner . *** ...

  • Continental CDVS500-N - page 8

    8 W415-0514 / 05.30.05 5 7 " f ir s t r u n 7 2 " s e c o n d r u n 4 8 " Use the chart on this page to calculate horizontal runs for vertical rises between 29 and 57 inches. FIGURE 8. When calculating maximum run lengths, include 10 feet for each 90° elbow or 5 feet for each 45° elbow . (DO NOT INCLUDE THE FIRST ELBOW DIRECTL Y OF ...

  • Continental CDVS500-N - page 9

    9 W415-0514 / 05.30.05 This application occurs when venting through an ex- terior wall. FIGURES 5 , 6, & 13 . Having deter- mined the air terminal loca- tion, cut and frame a hole in an exterior wall with a mini- mum square or round open- ing of 9". (As an alternative to framing, a vent pipe shield may be installed, en- suring a 1" cl ...

  • Continental CDVS500-N - page 10

    10 W415-0514 / 05.30.05 FIGURE 17 FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA FOR SAFE AND PROPER OPERA TION OF THE TION OF THE TION OF THE TION OF THE TION OF THE ST ST ST ST ST O O O O O VE, FOLL VE, FOLL VE, FOLL VE, FOLL VE, FOLL O O O O O W THE VENTING INSTR W THE VENTING INSTR W THE ...

  • Continental CDVS500-N - page 11

    11 W415-0514 / 05.30.05 In Canada, mobile home installation may be vented hori- zontally or vertically . In the United S tates, it may only be installed vertically . See "V ertical V enting" or "Horizontal Air T erminal Installation" for inst allation. The fireplace is equipped with two 5/16" diameter holes located near eac ...

  • Continental CDVS500-N - page 12

    12 W415-0514 / 05.30.05 Follow the instructions for " Wall and Ceiling Protection". ADAPTER INST ALLA TION FIGURE 27 1. Remove the spill switch bracket from the rear of the adapter . 2. Gently pull the two wire terminals (located inside the 7" flue collar at the top of the stove) out approximately 8 inches. 3. Bring the wires through ...

  • Continental CDVS500-N - page 13

    13 W415-0514 / 05.30.05 Remove nails from the shingles above and to the sides of the chimney . Place the flashing over the vent pipe and slide it underneath the sides and upper edge of the shingles. Ensure that the vent pipe is properly centered within the flashing, giving a 3/4" margin all around. Fasten to the roof on the top and sides. DO N ...

  • Continental CDVS500-N - page 14

    14 W415-0514 / 05.30.05 Read the section on opening the door in "Finish- ing" prior to proceeding to prevent damaging the unit. Bring the gas line to the stove through either the opening in the pedestal back or through the floor directly beneath the pedestal base. Install rigid black pipe or ½" type L copper tubing with a shut-off v ...

  • Continental CDVS500-N - page 15

    15 W415-0514 / 05.30.05 When opening the fire viewing door , a simple procedure must be followed in order to not damage the door . First open the valve control door . Next open both side doors fully . Pull the latch handles towards you and release each catch. The door may now be safely opened. T o close the door , repeat in reverse order . There ma ...

  • Continental CDVS500-N - page 16

    16 W415-0514 / 05.30.05 LOG PLACEMENT POSITIONING THE LOGS IMPROPERL Y WILL CAUSE FLAME IMPINGEMENT AND CARBONING . PHAZER TM logs and charcoal embers strips, exclusive to Continental Fireplaces, glow when exposed to direct flame and provide a unique and realistic glowing effect that is dif- ferent in every installation. Use only certified PHAZER T ...

  • Continental CDVS500-N - page 17

    17 W415-0514 / 05.30.05 This is a thermally activated switch, attached to the back of the chimney adapter , which senses the change in temperature and shuts down the gas valve in the event of a severe downdraft of air or a blocked or disconnected vent. It acts as a safety shut-off to prevent a build up of carbon monoxide or an explosion of unburnt ...

  • Continental CDVS500-N - page 18

    18 W415-0514 / 05.30.05 TURN OFF THE GAS AND UNPLUG ELECTRI- CAL POWER BEFORE SERVICING THE STO VE! CAUTION: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dan- gerous operation. V erify proper operation after servicing. This insert and its venting system should be inspected before use and at ...

  • Continental CDVS500-N - page 19

    19 W415-0514 / 05.30.05 1. Turn off the electrical power and the gas supply to the stove. 2. Open the lower louvre control door , the two side doors, and the fire viewing door . Remove the logs. 3. Remove the relief door held on with 6 screws. Discard the gasket. 4. Disconnect the two blower wires. Remove the blower bracket held on with 4 screws. 5 ...

  • Continental CDVS500-N - page 20

    20 W415-0514 / 05.30.05 Remove the pilot screw cap. Adjust the pilot screw to pro- vide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Replace the pilot screw cap. FIGURE 46 FIGURE 47 FIGURE 48 Air shutter adjustment must only be done by a qualified gas installer! FIGURE 49 T o access the venturi, remove the screw secu ...

  • Continental CDVS500-N - page 21

    21 W415-0514 / 05.30.05 GD175 WALL TERMINAL KIT 44 BM6790 90° ELBOW - 7" DIAMETER 45 GD222 TERMINAL ASSEMBL Y 4 6 BM67ADJ 30" TO 53" ADJUST ABLE PIPE - 7" DIA 4 7 W500-0077 FIRESTOP / WALL PLA TE 4 8 W020-0032 HARDWARE 49 BRTC7 BRASS TRIM COLLAR 50 BM6724 24" STOVE PIPE - 7" DIAMETER 5 1 W010-0300 10' ALUMINUM FL ...

  • Continental CDVS500-N - page 22

    22 W415-0514 / 05.30.05 WARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd. ...

  • Continental CDVS500-N - page 23

    23 W415-0514 / 05.30.05 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is cracked or broken. - replace the ...

  • Continental CDVS500-N - page 24

    24 W415-0514 / 05.30.05 Main burner goes out; pilot goes out. REFER TO "MAIN BURNER GOES OUT ; PILOT ST A YS ON" Thermocouple shorting or faulty . V ent re-circulating (MODEL CDVS500 ONL Y) - check joint seals and installation. - loosen and tighten thermocouple - clean thermocouple and valve connection. - replace thermocouple. - replace v ...

Fabbricante Continental Categoria Indoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoContinental CDVS500-N possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Continental
- manuali per l’uso CDVS500-N
- schede prodotto Continental
- opuscoli
- o etichette energetiche Continental CDVS500-N
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Continental CDVS500-N.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Continental CDVS500-N, manuali di manutenzione, brevi manuali o manuali utente Continental CDVS500-N. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Continental CDVS500-N.

Manuali per l’uso simili

Manuale completo del dispositivo Continental CDVS500-N, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Continental CDVS500-N dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Continental CDVS500-N.

Il manuale per l’uso completo Continental, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Continental CDVS500-N - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Continental CDVS500-N, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Continental CDVS500-N che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Continental CDVS500-N - che ci dovrebbe aiutare nei primi passi durante l'uso Continental CDVS500-N
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Continental CDVS500-N
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Continental CDVS500-N in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Continental CDVS500-N?

Utilizza il modulo sottostante

Se non hai risolto il problema con Continental CDVS500-N con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Continental CDVS500-N è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)