    This water heater must be installed an d servic ed by an authorised person. Please leave t his guide with the householder. “Streamline Closed Circuit” GAS BOOSTED SOLAR WATER HEATER OWNER’S MANUAL AND WARRANTY / INSTALLATION INFORMATION WARNING: Plumber – Be Aware Use copper pipe ONLY . Plastic pipe MUST NOT be used. It is a requirement of ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 2

    PATENTS This water heater may be protected by one or more patents or registered designs. ® Registered trademark of Solahart Industries Pty Ltd or Rheem Australia Pty Ltd. ™ Trademark of Solahart Industries Pty Ltd or Rheem Australia Pty Ltd. Notice to Victorian Customers from the Victorian Plumbing Industry Commission. This water heater must be ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 3

    3 CONTENTS HOUSEHOLDER – We recommend you read pages 5 to 16. The other pages are intended for the installer but may be of interest. Introduction ................................................................................................................... 4 About Your Water Heater ............................................................ ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 4

    4 INTRODUCTION Congratulations on choosing a “STREAMLINE CLOSED CIR CUIT GAS BOOSTED” solar water heater. We are confident that your pur chase will provide you many years of trouble free hot water. All over the world, the Solahart name is synon ymous with quality in wa ter heating. From humble beginnings in the pioneering days of Western Austra ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 5

    5 ABOUT YOUR WATER HEATER MODEL TYPE Congratulations for choosing a Solahart ® water heater. Your Solahart Streamline closed circuit solar water heater is designed for the solar collectors to be roof mounted and the solar storage tank to be installed at ground or floor level. The solar storag e t ank is suitable for outdoor installation only and w ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 6

    ABOUT YOUR WATER HEATER 6 SAFETY This water heater is supplied wi th temperature sensor s, a FlameSafe™ prot ection system, pressure relief valves and a combination temperature pressure reli ef valve. These devices must not be tampered with or removed. The water he ater must not be opera ted unless each of these de vices is fitted and is in worki ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 7

    ABOUT YOUR WATER HEATER 7 TO TURN ON THE WATER HEATER • Screw in the drain pl ugs at the cold water inlet a nd hot water outlet of the gas booster if the gas booster has been drained. • Open the cold water isolation valve fu lly at the inlet to the water heater. • Open all of the hot water taps in the house (don’t forget the shower). Air wi ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 8

    ABOUT YOUR WATER HEATER 8 DOES THE WATER QUALITY AFFECT THE WATER HEATER? The water heater is suitable for most public wate r supplies, however some water q ualities may have detrimental effects on the cylinder, ga s booster heat excha nger and fittings. If you are in a known harsh w ater area y ou must read page 52 . If you are not sure, have your ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 9

    ABOUT YOUR WATER HEATER 9 DRAINING THE GAS BOOSTER WATER HEATER • Turn off the water heater (refer to “Turn Off The Water Heater” on page 6). • Open a hot tap (preferably the shower outlet). • Unscrew the two drain plugs, one each at the cold water inlet and hot water outlet, on the underside of the water heater. Water will drain from the ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 10

    10 HOW YOUR WATER HEATER WORKS SOLAR OPERATION The Solahart Streamline closed circuit solar water he ater has its vitreous enamel lined solar storage tank installed at ground or floor level, remotely from the solar collectors. This water heater is an indirect solar hot water system with a heat exchanger in the solar storage tank. The heat exchanger ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 11

    HOW YOUR WATER HEATER WORKS 11 MAINS PRESSURE The water heater is designed to op erate at mains pressure by connec ting directly to the mains water supply. If the mains supply pressu re in your area exceeds that shown on page 19, a pr essure limiting valve must be fitted. The supply pressure should be greater than 3 50 kPa for true mains pressure o ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 12

    12 REGULAR CARE TEMPERATURE PRESSURE RELIEF VALVE This valve is near the top of the wa ter heater and is essential for its safe operation. It is possible for the valve to release a little water through the drain line during each heating period. This occurs as the water is heated and expands by approxim ately 1/50 of its volume. Continuous leakage o ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 13

    13 SAVE A SERVICE CALL Check the items below before making a service call. You will be charged for attending t o any condition or fault that is not related to manufacture or failure of a part. COLD WATER FROM THE HOT TAP • Close the hot tap, wait 10 seconds and open the hot tap again. • Is the hot tap open enough? The gas booster burners will n ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 14

    SAVE A SERVICE CALL 14 • Are you using more hot water than y ou think? Is one outlet (especially the shower) us ing more hot water than you think? Very often it is not realised the amou nt of hot water used, particu larly when showering. Carefully review the family’s hot water usage. As you h av e installed an energy saving appliance, energy sa ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 15

    SAVE A SERVICE CALL 15 TEMPERATURE PRESSURE RELIEF VALVE RUNNING • Normal Operation It is normal and desirable this valve allows a small quantity of water to escape during the heat ing cycle. However, if it discharges more than a bucket full of water in 24 hours, there may be another problem. • Continuous dribble Try gently raising the easing l ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 16

    SAVE A SERVICE CALL 16 CLOUDS OF WHITE ‘VAPOUR’ FROM THE FLUE TERMINAL During the heating cycle, it is not unusual to see water vapour clouds steaming from the flue terminal, particularly on cold da ys. This is normal operation of the gas booster. ERROR CODE The water heater provides a diagnos tic error code in the event of an interruption to i ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 17

    17 INSTALLATION – SOLAR STORAGE TANK THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. Check the water heater is suitable for the gas type available. (refer to the rating label on the water heater) The system is suitable for installation with Solahart ‘J’ or ‘KF’ solar collectors. The ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 18

    INSTALLATION – SOLAR STORAGE TANK 18 The top of the solar storage tank must be a mi nimum of 500 mm below the bottom of the solar collectors for the system to operate correctly. As a guide the following requirements extracted from the Australian Gas Installations Standard AS 5601, must be observed. • At least 300 mm between the t op of the gas ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 19

    INSTALLATION – SOLAR STORAGE TANK 19 MAINS WATER SUPPLY Where the mains water supply pressure e xceeds that shown in the table below, an appr oved pressure limiting valve is required and should be fitt ed as shown in the installation diagram (refer to diagram on page 29 ) . Model 270 Relief valve setting 1000 kPa Expansion control valve setting * ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 20

    INSTALLATION – SOLAR STORAGE TANK 20 RAIN WATER TANK If the solar collectors and solar pipe work are to b e inst alled on a section of roof which is part of a rain water runoff collection system, then it is recommended this section of roof and its gutter be isolated from the rain water collection system. The gutter s hould be isolated to a widt h ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 21

    INSTALLATION – SOLAR STORAGE TANK 21 HOT WATER DELIVERY This water heater can deliver water at temperatures which can cause scalding. This water heater ha s both a hot water outlet connection and a tempered wate r outlet connection. T he temperature of the water from the hot water outlet can be up to 75°C and the water from the tempere d water o ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 22

    INSTALLATION – SOLAR STORAGE TANK 22 CIRCULATED HOT WATER FLOW AND RETURN SYSTEM A solar water heater should not be installed as part of a circulated hot water flow and return system in a building. The benefits of solar gain will be signifi cantly reduced and energy gained from the sun lost through the pipe work. If a circulated flow and return s ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 23

    INSTALLATION – SOLAR STORAGE TANK 23 REDUCING HEAT LOSSES The cold water line to and the temp ered water and hot water lines from the wate r heater must be insulated in accordance with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed. The pipe work between the solar stora ge tank and the solar col ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 24

    INSTALLATION – SOLAR STORAGE TANK 24 DIMENSIONS AND TECHNICAL DATA Model DBV 270 Capacity 270 litres Mass 165 kg (empty) 435 kg (full) Test Point Gas Pressure (kPa) Gas Booster Details Gas Booster Model Delivery 25°C rise (litres / min) Hourly Gas Consumption (MJ) Min. Gas Pressure (kPa) minimum maximum Max. Gas Pressure (kPa) Natural 271 026 NF ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 25

    INSTALLATION – SOLAR STORAGE TANK 25 TYPICAL INSTALLATION – OUTDOOR LOCATION ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 26

    26 INSTALLATION – SOLAR COLLECTORS SOLAR COLLECTOR LOCATION Consideration must be given to the position of the solar collectors in relation to the solar storage tan k. There are limitations on both t he maximum length of the solar hot and solar cold pipes and the maximum height between the solar storage tank and the solar collectors. Refer to “ ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 27

    INSTALLATION – SOLAR COLLECTORS 27 PIPE LENGTHS The solar hot and solar cold pipes between the so lar storage tank and the solar collectors shall: • be of DN15 hard drawn c opper pipe. • have a continuous fall from the solar collector s to the solar storage tank of a minimum 5 ° (1 in 10 grade). • not exceed the maximum recommended l ength ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 28

    INSTALLATION – SOLAR COLLECTORS 28 WARNING: Plumber – Be Aware • The solar hot and solar cold pipes between th e solar storage tank and the solar collectors MUST BE of copper and fully insulated with closed cell polymer insulation or similar (minimum thickness 13 mm). The insulation must be weather proof and UV resistant if exposed. All compr ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 29

    29 CONNECTIONS – PLUMBING CONNECTION SIZES • Hot water connection: RP¾/20. • Cold water connection: RP¾/20. • Tempered water connection: RP¾/20 • Solar hot (from collector) connec tion: DN15 compression fitting. • Solar cold (to collector) c onnection: DN15 compression fitting. • Temperature Pressure Relief valve connection: RP½/1 ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 30

    CONNECTIONS – PLUMBING 30 This solar storage tank has either a plastic dip tube or fitting liner in the inlet and out let fittings (see diagram). These must be in place for the water heater to function properly. Do not remove or damage them by using hea t nearby. They will be pushed into the correct position as the fitting is screwed in. PIPE SIZ ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 31

    CONNECTIONS – PLUMBING 31 In locations where water pipes are pr one to freezing, the drain line must be insulated a nd not exceed 300 mm in length. In this instance, the drain line is to discharge into a tundish throug h an air gap of between 75 mm and 150 mm. EXPANSION CONTROL VALVE Local regulations may make it mandatory to install an e xpansio ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 32

    CONNECTIONS – PLUMBING 32 To connect the solar cold and solar ho t pipes to the solar storage tank: • Remove the compression nut and olive from eac h of the solar cold outlet and solar hot inlet fittings at the top of the solar storage tank. Remove the rubber washer from each of the unio ns and discard. • Connect the solar cold pipe (flow to ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 33

    33 CONNECTIONS – ELECTRICAL The power supply to the water heater must not be switched on until the water heater is filled wit h wa te r. MEGGER READING It is not mandatory to conduct a megge r test on a plug in appliance, however if a megger test is conducted on this water heater, t hen the following should be noted. Warning: This water heater co ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 34

    CONNECTIONS – ELECTRICAL 34 HOT SENSOR LEAD House the hot sensor lead at the water heater in the flexible c onduit provided and secure the conduit in the cut out on the tab located behind the upper front cover. Connect the hot sensor c able to the hot sensor cable connector located on th e tab behind t he upper front cover. Secure the hot sensor ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 35

    35 COMMISSIONING TO FILL AND TURN ON THE WATER HEATER The power supply to the solar storage tank and solar control unit must not be switched on until the water heater is filled with water . • Open all of the hot water taps in the house (don’t forget the shower). • Open the cold water isolation valve fully on the cold water line to the water h ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 36

    COMMISSIONING 36 SOLAR CIRCUIT It is necessary to commission and check the operation of the solar circuit. The commissioning procedure includes: • checking the circulation of closed ci rcuit fluid through the solar circuit. • checking the drain back function of the solar circuit. • pressure testing the solar circuit to ensure there are no lea ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 37

    COMMISSIONING 37 Warning: Although non-toxic, the following first aid advice and procedures should be followed if the closed circuit fluid concentrate come s into human contact or is spilt: • Swallowed - give milk or wate r and seek medical attention. • Eyes - wash with running water. • Skin - remove contaminated clothi ng and wash skin with ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 38

    COMMISSIONING 38 Commissioning the Solar Circuit To commission and check the solar circuit: 1. Switch off the electrical supply at the power outlet to the solar storage tank. If the pump has been operating, wait five minutes to allow the drain back of the closed circuit fluid in the solar circuit. 2. Remove the pipe cover from below the gas booster ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 39

    COMMISSIONING 39 6. Open the heat exchanger drain valve and remove the plug from the end of the hose. The closed circuit fluid will flood the hose to the static level of the closed circuit fluid inside of the heat exchanger. 7. Mark the static level of the closed circuit fluid on the side of the solar storage t ank with a non permanent marker. Sola ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 40

    COMMISSIONING 40 10. Check the closed circuit fluid is circulating around the solar circuit. To check circulation:  Listen for the trickling sound of the closed circuit fluid returni ng into the heat exchanger by placing your ear against the side towa rd the top of the solar storage tank. If the fluid is circulating arou nd the solar circuit, a ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 41

    COMMISSIONING 41 Drain Back Function 13. Switch off the electrical supply at the power outlet to the solar storage tank. The pump will deactivate. The closed circuit fluid will drain back down to the heat exchanger and the l eve l of the closed circuit fluid in the clear hose will rise. Wait five (5) minutes to allow the drain back of the closed ci ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 42

    COMMISSIONING 42 Closed Circuit Fluid Level 15. Measure the distance from t he text marking “MINIMUM FLUID LEVEL WITH PUMP OPERATING” to the closed circuit fluid dynam ic level marked on the side of the solar storage tank during step 11. The correct closed circuit fluid dynamic level for efficient operati on of the system when the pump is opera ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 43

    COMMISSIONING 43 16. Determine the correct amount of water to be added to or closed circuit fluid to be drained from the heat exchanger if the dy namic level is either bel ow the te xt marking “MINIMUM FLUID LEVEL WITH PUMP OPERATING” or mo re than 150 mm above this mark. Each 100 mm of fluid level height is equivalent to three (3) litres of cl ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 44

    COMMISSIONING 44 17. Add water to top up the level of the closed circuit fluid in the heat exchanger if required. To add water to the closed circuit fluid:  If not already removed, disconnect the drain line and r emove the spring clip from the solar circuit relief valve at the top of the solar storage tank and remove the valve (refer to step 5 ) ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 45

    COMMISSIONING 45 Pressure Testing the Solar Circuit 20. Close the heat ex changer drain valve. 21. Refit the solar circuit relie f valve, orientating the valve outlet to the rear of the solar storage tank. Secure with the spring clip. Reconnect the drain pipe to the valve. 22. Switch on the electrical supply at the power outlet to the solar storage ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 46

    COMMISSIONING 46 Remove Closed Circuit Fluid Level Hose 28. Remove the clear hose from the solar storage tank when satisfied the commissioning procedure is complete. To remove the hose:  Ensure the heat exchanger drain valve is closed.  Remove the hose from the side of the storag e tank and place the end into a contain er to collect the close ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 47

    COMMISSIONING 47 DIAGNOSTIC FEATURES OF THE SOLAR CONTROLLER The solar storage tank incorporates an electronic so lar control module. This is located inside of the lower front cover and houses both a green and a red LE D. The LEDs emit either a constant glow or a series of flashes with a 2 second interval bet w een flashes. The green LED indicates ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 48

    COMMISSIONING 48 GAS INLET PRESSURE IMPORTANT - CHECK the gas supply pressure at the inlet to the water heater with the water heater and all other gas burning appliances in the pre mises operating (burners alight). The minimum gas supply pressure is: Natural Gas 1.13 kPa Propane 2.75 kPa If this minimum cannot be achieved, it may indicate the meter ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 49

    COMMISSIONING 49 Minimum test point gas pressure Refer to the rating label on the water heater for the minimum test point gas pressure. 1. Open a hot tap slowly until the burners ignite. 2. Press and hold down the MIN button (“1L” is shown on the LED display), and observe the reading on the manometer. 3. Release the MIN button. If the manometer ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 50

    COMMISSIONING 50 Maximum test point gas pressure Refer to the rating label on the water heater for the maximum test point gas pressure. Follow Steps 1 to 7 of the “Minim um test point gas pressure” proc edure, but open the ho t tap fully and use the MAX button inste ad of the MIN button. Note: In Step 2, “3H” or “4H” will be shown on th ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 51

    51 DRAINING THE WATER HEATER To drain the water heater: Gas Booster Water Heater • Turn off the water heater (refer to “To Turn Off The Water Heater” on page 50). • Open a hot tap (preferably the shower outlet). • Unscrew the two drain plugs, one each at the cold water inlet and hot water outlet, on the underside of the gas booster. Water ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 52

    52 WATER SUPPLIES Your water heater is manufactured to suit the water conditions of mo st Australian metropolitan supplies. However, there are some known w ater supplies which can have detrimental effects on the water heater and its operation and/or life expectanc y. If you are unsure of your water quality, you can obtain information from your loca ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 53

    53 SOLAHART STREAMLINE, SYNERGY, GAS BOOSTER SOLAR WATER HEATER WARRANTY – AUSTRALIA ONLY WARRANTY CONDITIONS 1. This warranty is applicable only t o water heaters manufactured from 1 st July 2006. 2. The water heater must be installed in accorda nce with the Solahart water heater installation instructions, supplied with the water heater, and in ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 54

    SOLAHART STREAMLINE, SYNERGY, GAS BOOSTER SOLAR WATER HEATER WARRANTY – AUSTRALIA ONLY 54 WARRANTY Solahart* will: a) Repair or, if necessary replace any Solahart water heater; or b) Replace any component (or, if necessary, arrange the i nstallation of a new wa ter heater), which falls within the Warranty Periods specified below, subjec t to the ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 55

    55 SOLAHART INSTALLATION AND WARRANTY REPORT Dear Customer – To register your warranty please ensure the following information is correct then sign and return to our Solahart Industries Pty Ltd freepost address: Solahart Industries Pty Ltd. Reply Paid Perth 354, Welshpool, Western Australia 6106 WARRANTY Details and conditions of warranty are in ...

  • Rheem GAS BOOSTED SOLAR WATER HEATER - page 56

    56 SOLAHART OFFICES Corporate Headquarters 112 Pilbara St Welshpool Western Australia 6106 Postal Address: PO Box 95 State Parcel Centre Welshpool WA 6986 Telephone International: + 61 8 9351 4600 Facsimile International: + 61 8 9351 4698 Email: solahart@solahart.com.au Internet: www.solahart.com.au Australian Offices Wester n Australia New South W ...

Fabbricante Rheem Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoRheem GAS BOOSTED SOLAR WATER HEATER possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Rheem
- manuali per l’uso GAS BOOSTED SOLAR WATER HEATER
- schede prodotto Rheem
- opuscoli
- o etichette energetiche Rheem GAS BOOSTED SOLAR WATER HEATER
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Rheem GAS BOOSTED SOLAR WATER HEATER.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Rheem GAS BOOSTED SOLAR WATER HEATER, manuali di manutenzione, brevi manuali o manuali utente Rheem GAS BOOSTED SOLAR WATER HEATER. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Rheem GAS BOOSTED SOLAR WATER HEATER.

Manuali per l’uso simili

Manuale completo del dispositivo Rheem GAS BOOSTED SOLAR WATER HEATER, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Rheem GAS BOOSTED SOLAR WATER HEATER dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Rheem GAS BOOSTED SOLAR WATER HEATER.

Il manuale per l’uso completo Rheem, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Rheem GAS BOOSTED SOLAR WATER HEATER - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Rheem GAS BOOSTED SOLAR WATER HEATER, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Rheem GAS BOOSTED SOLAR WATER HEATER che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Rheem GAS BOOSTED SOLAR WATER HEATER - che ci dovrebbe aiutare nei primi passi durante l'uso Rheem GAS BOOSTED SOLAR WATER HEATER
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Rheem GAS BOOSTED SOLAR WATER HEATER
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Rheem GAS BOOSTED SOLAR WATER HEATER in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Rheem GAS BOOSTED SOLAR WATER HEATER?

Utilizza il modulo sottostante

Se non hai risolto il problema con Rheem GAS BOOSTED SOLAR WATER HEATER con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Rheem GAS BOOSTED SOLAR WATER HEATER è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)