  • Fluke 5626/5628 - page 1

    5626/5628 Platinum Resistance Thermometer User’ s Guide Rev. 532801 Hart Scientific ...

  • Fluke 5626/5628 - page 2

    Rev. 532801 Fluke Hart Scientific • 799 E. Utah Valley Drive • American Fork, UT 84003-9775 • USA Phone: +1.801.763.1600 • Telefax: +1.801.763.1010 • E-mail: support@ hartscientific.com www.hartscientific.com Subject to change without notice. • Copyright © 2005 • Printed in USA ...

  • Fluke 5626/5628 - page 3

    T able of Contents 1 Befor e Y ou Start . . . . . . . . . . . . . . . . . . . . . . 1 1 . 1 Symbols Used . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 .2 Safety Information . . . . . . . . . . . . . . . . . . . . . . . 2 1 .2. 1 W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1 .2.2 Cautions . . . . . . . . . . . ...

  • Fluke 5626/5628 - page 4

    7 . 1 Case Options . . . . . . . . . . . . . . . . . . . . . . . . . 1 5 7 .2 P RT T ermination . . . . . . . . . . . . . . . . . . . . . . . 1 5 8 Tr oubleshooting . . . . . . . . . . . . . . . . . . . . . 1 7 8. 1 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 1 7 ii ...

  • Fluke 5626/5628 - page 5

    iii Figures Figure 1 Hart Model 5626 and 5628 Platinum Resistance Thermometers . . . . . . 5 Figure 2 Standard Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 3 PRT Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Figure 4 Probe T ermination Examples . . . . . . . . . . . . . . . . . . . . . . . ...

  • Fluke 5626/5628 - page 6

    iv T ables T able 1 International Electrical Symb ols . . . . . . . . . . . . . . . . . . . . . . 1 T able 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 ...

  • Fluke 5626/5628 - page 7

    1 Before Y ou Start 1.1 Symbols Used T able 1 lists the Inter national Electrical Symbols . Some or all of these sym - bols may be used on the instrument or in this manual. Symbol Description AC (Alternating Current) AC-DC Battery C E Complies w ith European Union Directives DC Double Insulated Electric Shock Fuse PE Gr o un d Hot Surface (Bur n Ha ...

  • Fluke 5626/5628 - page 8

    Symbol Description Canadian Standards Association OVE RVOL T AG E (Installation) C A TE G ORY I I, Pollution Degree 2 per I E C 1010 - 1 r e f e r s t o t h e l e v e l o f I m p u l s e W i t h s t a n d V o l t a g e p r o t e c t i o n provided . Equipment of OV E R VOL T AG E CA T E GO RY II is en ergy-con - suming equipment to be supplied f ro ...

  • Fluke 5626/5628 - page 9

    • DO N OT drop or bang the probe in any way . This w ill cause damage to the probe internally and affect its calibration. • Read Section 5 entitled “PRT Care and Handling Guidelines” before re - moving the P RT from the shipping box or case. Incorrect handling can damage the PRT and void the warranty . • Keep the shipping container in cas ...

  • Fluke 5626/5628 - page 10

    Phone: +86-1 0-6-5 1 2-3436 T elefax: +86-1 0-6-5 1 2-343 7 E-mail: xing ye.han@fluke.com .cn Fluke South East Asia Pte Ltd . Fluke AS EAN Reg ional Office Serv ice Center 60 Alexandra T errace #03-1 6 The Comtech (Lobby D) 1 1 8502 S INGAPORE Phone: +65 6 799-5588 T elefax: +65 6 7 99-5588 E-mail: antng@singa .fluke.com When contacting these Ser v ...

  • Fluke 5626/5628 - page 11

    2 Introduction 2.1 General The Hart Platinum Resistance Thermometers (P RT) models 5626 and 5628, are designed to b e the best sec ondary standard interpolating instrument converting temperature to resistance. The P RTs are used with a readout de - vic e to detect temperature changes or actual temperature. The P RTs cover the International T empera ...

  • Fluke 5626/5628 - page 12

    calibrated using a primar y standard that has been calibrated in a primary calibration laborator y using know n intrinsic values . 2.3 Calibration In order for any instrument to be used as a standard it must be calibrated. The PRTs are calibrated in Hart Scientific's calibration laborator y and pro - vided w ith a N I S T trac eable “Report ...

  • Fluke 5626/5628 - page 13

    3 Specifications and W arranty 3.1 Specifications See T able 2 and Figure 2. 7 3 Specifications and Warranty 5626 5628 Temperature Range –200°C to 661°C R tp 100 Ω ±1 Ω at 0.01°C 25.5 Ω ±0.5 Ω at 0.01°C Resistance RatioW(Ga) W(302.9146K) ≥ 1.11807 α ≥ 0.003925 Calibration Uncertainty (k=2) ±0.006°C at –200°C ±0.004°C at 0°C ...

  • Fluke 5626/5628 - page 14

    3.2 Construction The Model 5626 and 5628 P RT s cover the range from –200°C to 66 1°C . The sensor elements are crafted using high purity platinum w ire wound in a strain free design on a spec ially designed support . 3.3 Electrical Circuit The PRTs are provided w ith a terminal box handle. T he two meter cable has four Super-Flex w ires enclos ...

  • Fluke 5626/5628 - page 15

    4 Installation 4.1 Environmental Issues Ideally, temperature calibration equipment should be used in a calibration laborator y or other facility spec ifically designed for this purpose. Environ - mental requirements include: • Stable temperature and relative humidity <80% • Clean, draft-free area • Low noise level: low radio frequenc y, ma ...

  • Fluke 5626/5628 - page 16

    5 PRT Care and Handling Guidelines 5.1 PRT Care CAUT I O N: R E AD T H I S S E CT I O N B E FO R E RE M OVI N G T H E P RT FR O M T H E S H I P P I N G BOX O R CAS E The 5626 and 5628 Platinum Resistance Thermometers (P RTs) are delicate instruments. Care must b e taken in handling the P RT s to maintain calibra - tion accurac y . The stress free d ...

  • Fluke 5626/5628 - page 17

    • DO allow sufficient time for the thermometer to stabilize before making measurements. This allows for the best accurac y . • DO use the correct drive current with the thermometer to prevent error in temperature or resistance. Hart Scientific recommends 1mA. • DO anneal the thermometer at 600 to 66 1°C for 1 2 hours if it becomes oxidized. ...

  • Fluke 5626/5628 - page 18

    6 Operation 6.1 General F or best results, be familiar w ith the operation of the heat source and the r e a d - o u ti n s t r u m e n t .B es u r et of o l l o wt he manufacturer’s instructions for the read-out instrument and the heat source. 6.2 Comparison Calibration of Other Instruments The uniformity and stability of the heat source and the ...

  • Fluke 5626/5628 - page 19

    6.4 Thermal EMF Two factors contribute to thermal E M F, chemical c onsistency and physical consistenc y . V ariations in chemical structure due to impurities can contrib - ute to thermal E M F . Also discrepancies in crystal structure can contribute to thermal E M F . These factors are minimized by annealing the full length of wire b efore constru ...

  • Fluke 5626/5628 - page 20

    7 Accessories 7.1 Case Options The 5626/5628 PRT comes in a rig id case appropriate for the leng th of the probe. • Model Number 26 0 1 P RT Protective Case for 5626-1 2 and 5628-1 2 PR T • Model Number 26 02 PRT Protective Case for 5626-1 5, 5628-1 5, 5626-20, and 5628-20 PRT 7.2 PRT T ermination The 5626/5628 PRT can be terminated in three w ...

  • Fluke 5626/5628 - page 21

    8 T roubleshooting 8.1 T roubleshooting In the event that the probe appears to function abnormally, this section may be of use in solv ing the problem . Several possible problem conditions are described along w ith likely causes and solutions . If a problem arises, please read this section carefully and attempt to understand and solve the problem . ...

  • Fluke 5626/5628 - page 22

    Problem Causes and Solutions Temperature readout differ - ent than expected, e.g. the heat source is set at 300°C, the PRT measures 275°C. • Measure the PRT resistance at TPW. • If the resistance of the PRT is less than the rated resis - tance, e.g. 70 Ω for the 5626, there may be a short in the sensor. Contact an Authorized Hart Scientific ...

Fabbricante Fluke Categoria Thermometer

I documenti che otteniamo dal fabbricante del dispositivoFluke 5626/5628 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Fluke
- manuali per l’uso 5626/5628
- schede prodotto Fluke
- opuscoli
- o etichette energetiche Fluke 5626/5628
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Fluke 5626/5628.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Fluke 5626/5628, manuali di manutenzione, brevi manuali o manuali utente Fluke 5626/5628. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Fluke 5626/5628.

Manuali per l’uso simili

Manuale completo del dispositivo Fluke 5626/5628, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Fluke 5626/5628 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Fluke 5626/5628.

Il manuale per l’uso completo Fluke, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Fluke 5626/5628 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Fluke 5626/5628, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Fluke 5626/5628 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Fluke 5626/5628 - che ci dovrebbe aiutare nei primi passi durante l'uso Fluke 5626/5628
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Fluke 5626/5628
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Fluke 5626/5628 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Fluke 5626/5628?

Utilizza il modulo sottostante

Se non hai risolto il problema con Fluke 5626/5628 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Fluke 5626/5628 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)