  • York F3EH090 - page 1

    GENERAL These completely assembled indoor units include a well- insulated cabinet, a copper tube/aluminum fin coil, throw - away filters, a centrifugal blower , a blower motor , an adjust - able V -belt drive, a blower motor contactor and a small holding charge of an inert gas. They also include a filter- drier , an expansion valve and a distributo ...

  • York F3EH090 - page 2

    035-09651-001-A-0304 2 Unitary Products Group T ABLE OF CONTENTS GENERAL ............................................................................. 1 REFERENCE ............................................................................. 1 INSPECTION ............................................................................. 1 NOMENCLATURE ... ...

  • York F3EH090 - page 3

    rate request for inspection by the carrier's agent should be made in writing. LIMIT ATIONS These units must be installed in accordance with all national and local safety codes. If no local codes apply , installation must conform with the appropriate national codes. Units are de - signed to meet National Safety Code S tandards. If components ar ...

  • York F3EH090 - page 4

    035-09651-001-A-0304 4 Unitary Products Group FIG . 1 - UNIT SUSPENSION MOUNTING (Horizontal Application) Model Power Supply V oltage V ariation 1 Supply Air CFM Entering Air T emperatures, ° F Cooling - wb Heating - db Min. Max. Min. Max. Min. Max. Min. Max. F3EH090 208/230-3-60 187 252 2400 3600 57 72 50 2 80 460-3-60 414 506 380/415-3-50 342 45 ...

  • York F3EH090 - page 5

    WARNING: Do not permit overhanging structures or shrubs to obstruct air discharge. Additional height may be required for snow clearance if winter operation is expected. VERTICAL / HORIZONT AL INST ALLATION These indoor units are shipped for vertical installation with ver - tical air discharge as shown in Figure 2(A) but may be con - verted for hori ...

  • York F3EH090 - page 6

    Form 035-16650-001 – Supply Air Plenum Form 035-16621-001 – Return Air Grille Form 035-16632-001 – Base The supply air plenum and the return air grille should be used in lieu of ductwork only when a free blow/free return application is practical. REFRIGERANT MAINS Many service problems can be avoided by taking adequate precautions to provide ...

  • York F3EH090 - page 7

    A 7/8" OD drain connection extends through right hand side of cabinet. Refer to Fig. 7 for recommended drain piping. The drain connection is located on the same side of the unit as the refrigerant connections. The line should be insulated where moisture drippage will be objectionable or cause damage to the area. The 3" dimension must equa ...

  • York F3EH090 - page 8

    035-09651-001-A-0304 8 Unitary Products Group FIG . 9 - HOLE LOCA TIONS FOR PRESSURE DROP READINGS FIG . 10 - PRESSURE DROP ACROSS A DRY INDOOR COIL VS. SUPPL Y AIR CFM RPM CFM ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW ESP 2 BHP KW F3EH090 (60 Hz) 2400 2700 3000 3300 3600 600 0.30 0.62 0.79 0.21 0.70 0.76 0.09 0.78 0.89 ------ 655 0.43 0. ...

  • York F3EH090 - page 9

    035-09651-001-A-0304 Unitary Products Group 9 Model Accessory S tatic Resistance, IWG BLOWER CFM 2400 2700 3000 3300 3600 F3EH090 Electric Heat 10 KW 0.01 0.01 0.01 0.02 0.02 16 KW 0.01 0.02 0.02 0.03 0.04 26 KW 0.03 0.04 0.05 0.06 0.07 36 KW 0.05 0.07 0.08 0.10 0.1 1 Supply Air Plenum 0.03 0.03 0.04 0.05 0.06 Return Air Grille 0.02 0.03 0.04 0.05 ...

  • York F3EH090 - page 10

    POWER AND CONTROL WIRING Install electrical wiring in accordance with the latest National Electrical Code (NFP A S tandard No. 70) and/or local regula - tions. The unit should be grounded in accordance with these codes. Route the power wires into the unit through the 1-3/8” knockout in the rear panel, and connect them to the terminals on blower m ...

  • York F3EH090 - page 11

    035-09651-001-A-0304 Unitary Products Group 11 FIG .12 - UNIT DIMENSIONS & CLEARANCES (F3EH090 & F4EH120) All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. ACCESSORIES • ELECTRIC HEA TER - Add 14-1/4" to unit height when used. • SUPPL Y AIR PLENUM - Add 27-1 ...

  • York F3EH090 - page 12

    SECURE OWNER'S APPROV AL: When the system is functioning properly , secure the owner's approval. Show him the location of all disconnect switches and the thermostat. T each him how to start and stop the unit, how to adjust temperature settings within the limitations of the system, how the defrost cycle is controlled and how the anti-cycle ...

Fabbricante York Categoria Heat Pump

I documenti che otteniamo dal fabbricante del dispositivoYork F3EH090 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici York
- manuali per l’uso F3EH090
- schede prodotto York
- opuscoli
- o etichette energetiche York F3EH090
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso York F3EH090.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione York F3EH090, manuali di manutenzione, brevi manuali o manuali utente York F3EH090. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto York F3EH090.

Manuali per l’uso simili

Manuale completo del dispositivo York F3EH090, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare York F3EH090 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti York F3EH090.

Il manuale per l’uso completo York, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale York F3EH090 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice York F3EH090, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per York F3EH090 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo York F3EH090 - che ci dovrebbe aiutare nei primi passi durante l'uso York F3EH090
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del York F3EH090
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio York F3EH090 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su York F3EH090?

Utilizza il modulo sottostante

Se non hai risolto il problema con York F3EH090 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con York F3EH090 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)