Manuale per l’uso Zephyr AK7842ASX

19 pagine 0.61 mb
Scarica

Vai alla pagina of 19

Summary
  • Zephyr AK7842ASX - page 1

    Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: Date of Purchase: Sales Dealer: AUG08.0101 © Zephyr Corporation Cypress AK7836ASX AK7842ASX AK7848ASX READ AND SA VE THESE INSTRUCTIONS INTENDED FOR OUTDOOR COVERED P A TIO OR LANAI AREA. ...

  • Zephyr AK7842ASX - page 2

    www .zephyronline.com ...

  • Zephyr AK7842ASX - page 3

    1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...

  • Zephyr AK7842ASX - page 4

    Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...

  • Zephyr AK7842ASX - page 5

    Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operat ...

  • Zephyr AK7842ASX - page 6

    List of Materials 4 www .zephyronline.com MODELS: AK7836ASX, AK7842ASX, AK7848ASX P ARTS SUPPLIED 1 - Hood 3 - Baf fl e fi lters (4 for AK7848ASX) 2 - Halogen light bulbs (3 for AK7548ASX) ( pre-installed ) 1 - 10” round transition adapter ( for dual internal and external blowers ) 1 - External blower wiring ( for external and in-line blower ) ...

  • Zephyr AK7842ASX - page 7

    5 Installation – Ducting Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3-1/ 4” x 10” Rect., straight 1 Ft . x ( ) = Ft. 7”-10” Round, straight 1 Ft . x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 elb ow 15 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 3-1/ 4” x 10” Rect. 9 0 0 flat elb ow ...

  • Zephyr AK7842ASX - page 8

    Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air fl ow ef fi ciency for single blower and 10” round duct for dual, in-line, and external blowers. Always use rigid type metal ducts only . Flexible ducts could restrict ...

  • Zephyr AK7842ASX - page 9

    7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only . Fasten all connections with sheet metal screws and tape all joints with certi fi ed Silver T ape or Duct T ape. Some Ducting Options Installation ? ...

  • Zephyr AK7842ASX - page 10

    8 www .zephyronline.com Installation – Speci fi cations 35 15/16 ” (36”) 41 15/16 ” (42”) 47 15/16 ” (48”) 12” *10 ” 27” 4” 18” 1 1/8 ” 8 9/16 ” 13 3/16 ” 2 5/16 ” 6 7/16 ” 2” 2 1/16 ” C L 5 9/16” ext blwr k/o elec k/o 2 11 / 1 6 ” top side front 4 5/16 ” *10” transition used with dual, external and in ...

  • Zephyr AK7842ASX - page 11

    9 ELECTRICAL W ARNING All Electrical work must by performed by quali fi ed electrician or person with similar technical know how and background. For personal safety , remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing ...

  • Zephyr AK7842ASX - page 12

    10 www .zephyronline.com C/L C/L A B 12 3/8 ” min 30” 4” wood board fig. 2 fig. 1 Installation – Mounting the Range Hood 1. Measure distance from range top to hood bottom ( 30” min ) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. ( 12 3/8” from line A ) ( This is the top of the board used to hang th ...

  • Zephyr AK7842ASX - page 13

    11 CBI-600B AND PBI-1 100A BLOWER INST ALLA TION 1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2) 10x3/16” screws. (blower pictured is a PBI-1 100A) 2. Connect male end of blower wire to female plug in the hood. (plug is located inside the hood behind the control panel) 3. Single Blower – ...

  • Zephyr AK7842ASX - page 14

    12 www .zephyronline.com Installation – Remote Blower Preparation 1. Place 10” round adapter on top of hood and secure with (4) M4x8 screws. Connect 10” round duct work to 10” round adapter . 2. Install threaded end of external blower wiring through external blower wiring knock out located inside the hood. 3. Place cap over threaded end of ...

  • Zephyr AK7842ASX - page 15

    13 Light On/Off By pressing , the light is switched On and Off. is on, is off. Blower Speed Selection The 2 speed levels are selected by switching to for level one and for level two. Lights On/Off Adjust Blower Level (2 Speeds) 1 1 2 2 Switching the rocker switch to middle will turn off the blower. Features & Controls – Rocker Switch Controls ...

  • Zephyr AK7842ASX - page 16

    14 www .zephyronline.com SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser . After cleaning, you m ...

  • Zephyr AK7842ASX - page 17

    15 REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. I ...

  • Zephyr AK7842ASX - page 18

    T roubleshooting 16 www .zephyronline.com TROUBLESHOOTING PROCEDURES FOR CYPRESS Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the power co ...

  • Zephyr AK7842ASX - page 19

    17 DESCRIPTION P ART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Z0B-0023 Baf fl e Filter (each) 50210009 Optional Accessories Single Internal Blower CBI-600B Dual Internal Blower PBI-1 100A External Blower CBE-1000 In-Line Blower PBN-1000A Vinyl Cover (36”) AK0636AB Vinyl Cover (42”) AK0642AB Vinyl Cover (48”) AK0648AB 12” Duct ...

Fabbricante Zephyr Categoria Ventilation Hood

I documenti che otteniamo dal fabbricante del dispositivoZephyr AK7842ASX possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Zephyr
- manuali per l’uso AK7842ASX
- schede prodotto Zephyr
- opuscoli
- o etichette energetiche Zephyr AK7842ASX
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Zephyr AK7842ASX.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Zephyr AK7842ASX, manuali di manutenzione, brevi manuali o manuali utente Zephyr AK7842ASX. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Zephyr AK7842ASX.

Manuali per l’uso simili

Manuale completo del dispositivo Zephyr AK7842ASX, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Zephyr AK7842ASX dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Zephyr AK7842ASX.

Il manuale per l’uso completo Zephyr, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Zephyr AK7842ASX - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Zephyr AK7842ASX, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Zephyr AK7842ASX che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Zephyr AK7842ASX - che ci dovrebbe aiutare nei primi passi durante l'uso Zephyr AK7842ASX
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Zephyr AK7842ASX
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Zephyr AK7842ASX in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Zephyr AK7842ASX?

Utilizza il modulo sottostante

Se non hai risolto il problema con Zephyr AK7842ASX con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Zephyr AK7842ASX è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)