    Ve r t i c a l S el f- Con t ain e d A ir C ond i t ioning Air and Water Cooled 5 - 15 T ons 60 Hz PKG-PRC007-EN ...

  • Trane Genius PKG-PRC007-EN - page 2

    PKG-PRC007-EN ©American Standard Inc. 2000 Introduction The TRANE Company , a world leader in the HV AC industry , has developed another option to meet the needs of our customers . . . the Genius! Built to provide not only the indoor comfort but also the confidence that the unit is reliable, durable, easy to install and maintain. The Genius line h ...

  • Trane Genius PKG-PRC007-EN - page 3

    3 Contents PKG-PRC007-EN I ntroduction 2 Features and Benefits 4 Model Number Description 8 General Data 9 Selection Procedure 10 Performance Data 11 Controls 36 Electrical Data 37 Dimensions 47 Mechanical Specification 51 ...

  • Trane Genius PKG-PRC007-EN - page 4

    PKG-PRC007-EN 4 Features and Benefits The Genius line was built to provide not only ultimate indoor comfort but also the comfort of knowing that our self- contained units are reliable as well as easy to install and maintain. Genius is the most flexible vertical self- contained of the market. Suitable to use in offices, residences or restaurants. A ...

  • Trane Genius PKG-PRC007-EN - page 5

    5 PKG-PRC007-EN Features and Benefits Air Handling Section In accordance to the ASHRAE Standard 62-89 for Indoor Air Quality , T rane has developed an exclusive and innovative design for the drain pan. This design insures proper drainage, preventing conditions of water stagnation that could result in microbial growth. All the air handlers feature a ...

  • Trane Genius PKG-PRC007-EN - page 6

    PKG-PRC007-EN 6 Features and Benefits Integrated Self-Contained Systems: Profitable, Simple Integrated Comfort ™ System (ICS) T rane’ s Integrated Comfort ™ system improves job profit and increases job control by combining T rane self- contained units and a T racker ® building management system. This integrated system provides total building ...

  • Trane Genius PKG-PRC007-EN - page 7

    7 PKG-PRC007-EN Features Summary Quality and Reliability • Galvanized steel casing • Synthetic enamel paint • Innovative Drain Pan • Scroll Compressors Flexibility • Air or W ater Cooled • Free discharge plenum or ducted discharge • V oltages available: 220/3/60, 440/3/60, 380/3/60 and 380/50/3 Controls • Thermostat unit mounted or ...

  • Trane Genius PKG-PRC007-EN - page 8

    PKG-PRC007-EN 8 Model Number Description ...

  • Trane Genius PKG-PRC007-EN - page 9

    9 PKG-PRC007-EN T able GD-1 — Genius – General Data SA VE Model 050 T 075 T 100 2T 125 2T 150 2T Nominal TR Capacity 5 7.5 10 12.5 15 Length (mm) 960 1190 1500 1700 1700 Depth (mm) 600 600 600 600 600 Height (mm) 2000 2000 2000 2000 2000 Height w/ Plenum Box (mm) 2295 2295 2295 2295 2295 Net Weight (kg) 247 288 376 440 461 SRVE Model 050 T 075 ...

  • Trane Genius PKG-PRC007-EN - page 10

    PKG-PRC007-EN 10 Selection Procedure The selection of a Genius self-contained unit can be accomplished in three easy steps. 1 LOAD: Determine the load requirements for heating and cooling (include outside air) using T rane’ s load estimate forms, TRACE ® Easy/600 or any standard method. 2 UNIT TYPE: Self-contained air conditioners are available ...

  • Trane Genius PKG-PRC007-EN - page 11

    11 PKG-PRC007-EN Three transmission options exist for the evaporator fan motor: Std. option, option 1, option 2. In addition, there is an option for those cases in which the unit is operated with a plenum box. The motors for each transmission option can be found in the general facts tables. Performance Data Fan Data T able PD-1 — Fan Per formance ...

  • Trane Genius PKG-PRC007-EN - page 12

    PKG-PRC007-EN 12 Performance Data Fan Data T able PD-2 — Fan Per formance SRVE/SIVE/SA VE 7.5 T ons External static pressure with permanent air filter in ches of water (Pa) .08 .16 .24 .31 .39 .50 Model Airflow (19.9) (39.8) (59.8) (77.2) (97.1) (124.5) Option 7.5 TR CFM (m3/h) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2703 4590 688 0.64 72 ...

  • Trane Genius PKG-PRC007-EN - page 13

    13 PKG-PRC007-EN T able PD-3 — Fan Per formance SRVE/SIVE/SA VE 10 T ons External static pressure with permanent air filter in ches of water (Pa) .08 .16 .24 .31 .39 Model Airflow (19.9) (39.8) (59.8) (77.2) (97.1) Option 10 TR CF M (m3/h) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 3604 6120 839 0.84 875 0.89 911 0.94 945 1.00 979 1.07 MT 1.5 CV 375 ...

  • Trane Genius PKG-PRC007-EN - page 14

    PKG-PRC007-EN 14 Performance Data Fan Data T able PD-4 — Fan Per formance SRVE/SIVE/SA VE 12.5 T ons External static pressure with permanent air filter in ches of water (Pa) .08 .16 .24 .31 .39 .50 .63 Model Airflow (19.9) (39.8) (59.8) (77.2) (97.1) (124.5) (156.9) Option 12.5 TR C FM (m3/h) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BH ...

  • Trane Genius PKG-PRC007-EN - page 15

    15 PKG-PRC007-EN T able PD-5 — Fan Per formance SRVE/SIVE/SA VE 15 T ons External static pressure with permanent air filter in ches of water (Pa) .08 .16 .24 .31 .39 .50 Model Airflow (19.9) (39.8) (59.8) (77.2) (97.1) (124.5) Option 15 TR CF M (m3/h) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 5406 9180 664 1.22 696 1.30 728 1.38 759 1.48 78 ...

  • Trane Genius PKG-PRC007-EN - page 16

    PKG-PRC007-EN 16 T able PD-6 — Gross Cooling Capacities SA VE-050 English ENT Water T emp (°F) 75 85 Entering Wet Bulb T emperature (°F) Ent. 61 67 73 61 67 73 DB CFM (°F) TGC SHC GPM TGC SHC GPM TG C SHC GPM TGC SHC GPM TGC SHC GPM T GC SHC GPM 75 55.0 45.2 12.8 61.6 35.2 14.5 68.6 24.9 15.9 53.5 44.4 12.8 59.9 34.4 14.5 67.0 24.4 15.9 1800 8 ...

  • Trane Genius PKG-PRC007-EN - page 17

    17 PKG-PRC007-EN Performance Data W ater Cooled 60 Hz T able PD-6 — Gross Cooling Capacities SA VE-050 Metric ENT Water T emp (°C) 24.0 29.5 Entering Wet Bulb T emperature (°C) Ent. 16.0 19.5 23.0 16.0 19.5 23.0 DB m3/h (°C) TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s 24 16.1 13.2 0.81 18.0 10.3 0.92 20.1 7.3 1.00 1 ...

  • Trane Genius PKG-PRC007-EN - page 18

    PKG-PRC007-EN 18 T able PD-7 — Gross Cooling Capacities SA VE-075 English ENT Water T emp (°F) 75 85 Entering Wet Bulb T emperature (°F) Ent. 61 67 73 61 67 73 DB CFM (°F) TGC SHC GPM TGC SHC GPM TG C SHC GPM TGC S HC GPM TGC SHC GPM T GC SHC GPM 75 79.4 64.2 18.1 89.4 49.9 19.8 100.1 35.3 22.0 77.2 63.1 18.1 86.8 48.8 19.8 97.1 34.2 22.0 2700 ...

  • Trane Genius PKG-PRC007-EN - page 19

    19 PKG-PRC007-EN Performance Data W ater Cooled 60 Hz T able PD-7 — Gross Cooling Capacities SA VE-075 Metric ENT Water T emp (°C) 24.0 29.5 Entering Wet Bulb T emperature (°C) Ent. 16.0 19.5 23.0 16.0 19.5 23.0 DB m3/h (°C) TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s 24 23.3 18.8 1.14 26.2 14.6 1.25 29.3 10.3 1.39 ...

  • Trane Genius PKG-PRC007-EN - page 20

    PKG-PRC007-EN 20 T able PD-8 — Gross Cooling Capacities SA VE-100 English ENT Water T emp (°F) 75 85 Entering Wet Bulb T emperature (°F) Ent. 61 67 73 61 67 73 DB CFM (°F) TGC SHC GPM TGC SHC GPM TG C SHC GPM TGC S HC GPM TGC SHC GPM T GC SHC GPM 75 109.9 87.9 26.0 122.7 68.5 28.6 136.6 48.7 31.7 106.7 86.3 26.0 119.5 67.1 28.6 133.2 47.5 31.3 ...

  • Trane Genius PKG-PRC007-EN - page 21

    21 PKG-PRC007-EN Performance Data W ater Cooled 60 Hz T able PD-8 — Gross Cooling Capacities SA VE-100 Metric ENT Water T emp (°C) 24.0 29.5 Entering Wet Bulb T emperature (°C) Ent. 16.0 19.5 23.0 16.0 19.5 23.0 DB m3/h (°C) TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s 24 32.2 25.7 1.64 35.9 20.1 1.81 40.0 14.3 2.00 ...

  • Trane Genius PKG-PRC007-EN - page 22

    PKG-PRC007-EN 22 T able PD-9 — Gross Cooling Capacities SA VE-125 English ENT Water T emp (°F) 75 85 Entering Wet Bulb T emperature (°F) Ent. 61 67 73 61 67 73 DB CFM (°F) TGC SHC GPM TGC SHC GPM TG C SHC GPM TGC S HC GPM TGC SHC GPM T GC SHC GPM 75 135.8 109.8 31.3 151.7 85.3 34.4 169.3 60.3 37.9 131.7 107.9 31.3 147.4 83.5 34.4 164.4 58.5 37 ...

  • Trane Genius PKG-PRC007-EN - page 23

    23 PKG-PRC007-EN Performance Data W ater Cooled 60 Hz T able PD-9 — Gross Cooling Capacities SA VE-125 Metric ENT Water T emp (°C) 24.0 29.5 Entering Wet Bulb T emperature (°C) Ent. 16.0 19.5 23.0 16.0 19.5 23.0 DB m3/h (°C) TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s 24 39.8 32.2 1.97 44.5 25.0 2.17 49.6 17.7 2.39 ...

  • Trane Genius PKG-PRC007-EN - page 24

    PKG-PRC007-EN 24 T able PD-10 — Gross Cooling Capacities SA VE-150 English ENT Water T emp (°F) 75 85 Entering Wet Bulb T emperature (°F) Ent. 61 67 73 61 67 73 DB CFM (°F) TGC SHC GPM TGC SHC GPM TG C SHC GPM TGC S HC GPM TGC SHC GPM T GC SHC GPM 75 165.6 138.7 37.9 185.4 106.0 41.4 206.9 72.8 45.8 160.4 136.3 37.4 179.6 103.6 41.4 200.2 70.4 ...

  • Trane Genius PKG-PRC007-EN - page 25

    25 PKG-PRC007-EN Performance Data W ater Cooled 60 Hz T able PD-10 — Gross Cooling Capacities SA VE-150 Metric ENT Water T emp (°C) 24.0 29.5 Entering Wet Bulb T emperature (°C) Ent. 16.0 19.5 23.0 16.0 19.5 23.0 DB m3/h (°C) TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s TGC SHC l/s 24 48.5 40.6 2.39 54.3 31.1 2.61 60.6 21.3 2.89 ...

  • Trane Genius PKG-PRC007-EN - page 26

    PKG-PRC007-EN 26 T able PD-11 — Gross Cooling Capacities SRVE-050 English Ambient T emperature (°F) 85 95 Entering Wet Bulb T emperature (°F) Ent. 61 67 73 61 67 73 DB CFM (ºF) TGC SH C TGC SHC TG C SHC TGC SHC TGC SHC TGC SHC 75 53.7 44.2 60.2 34.1 67.1 23.9 52.2 43.5 58.4 33.4 65.1 23.1 1800 80 54.1 52.0 60.1 42.4 67.0 32.1 52.6 51.2 58.4 41 ...

  • Trane Genius PKG-PRC007-EN - page 27

    27 PKG-PRC007-EN Performance Data Air Cooled 60 Hz T able PD-11 — Gross Cooling Capacities SRVE-050 Metric Ambient T emperature (°C) 29.5 35.0 Entering Wet Bulb T emperature (°C) Ent. 16.0 19.5 23.0 16.0 19.5 23.0 DB m3/h (ºC) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 22.5 18.6 25.2 14.3 28.1 10.0 21.7 18.2 24.3 14.0 27.1 9.6 4590 27 ...

  • Trane Genius PKG-PRC007-EN - page 28

    PKG-PRC007-EN 28 T able PD-12 — Gross Cooling Capacities SRVE-075 English Ambient T emperature (°F) 85 95 Entering Wet Bulb T emperature (°F) Ent. 61 67 73 61 67 73 DB CFM (ºF) TGC SHC TGC SHC TGC S HC TGC SHC TGC SHC T GC SHC 75 76.6 63.5 85.9 48.9 95.8 34.0 74.1 62.2 83.0 47.7 92.5 32.9 2700 80 77.2 74.7 85.9 60.8 95.7 46.0 74.7 73.2 83.0 59 ...

  • Trane Genius PKG-PRC007-EN - page 29

    29 PKG-PRC007-EN Performance Data Air Cooled 60 Hz T able PD-12 — Gross Cooling Capacities SRVE-075 Metric Ambient T emperature (°C) 29.5 35.0 Entering Wet Bulb T emperature (°C) Ent. 16.0 19.5 23.0 16.0 19.5 23.0 DB m3/h (ºC) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 22.5 18.6 25.2 14.3 28.1 10.0 21.7 18.2 24.3 14.0 27.1 9.6 4590 27 ...

  • Trane Genius PKG-PRC007-EN - page 30

    PKG-PRC007-EN 30 T able PD-13 — Gross Cooling Capacities SRVE-100 English Ambient T emperature (°F) 85 95 Entering Wet Bulb T emperature (°F) Ent. 61 67 73 61 67 73 DB CFM (ºF) TGC SH C TGC SHC TG C SHC TGC S HC TG C SHC TGC SHC 75 107.1 86.8 120.1 66.3 134.0 45.5 103.8 85.1 116.3 64.6 129.7 43.8 3600 80 107.7 102.8 119.9 82.8 133.9 62.0 104.4 ...

  • Trane Genius PKG-PRC007-EN - page 31

    31 PKG-PRC007-EN Performance Data Air Cooled 60 Hz T able PD-13 — Gross Cooling Capacities SRVE-100 Metric Ambient T emperature (°C) 29.5 35.0 Entering Wet Bulb T emperature (°C) Ent. 16.0 19.5 23.0 16.0 19.5 23.0 DB m3/h (ºC) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 31.4 25.4 35.2 19.4 39.3 13.3 30.4 24.9 34.1 18.9 38.0 12.8 6120 27 ...

  • Trane Genius PKG-PRC007-EN - page 32

    PKG-PRC007-EN 32 T able PD-14 — Gross Cooling Capacities SRVE-125 English Ambient T emperature (°F) 85 95 Entering Wet Bulb T emperature (°F) Ent. 61 67 73 61 67 73 DB CFM (ºF) TGC SH C TGC SHC TG C SHC TGC SHC TGC SHC TGC SHC 75 131.7 108.3 147.0 83.5 163.7 58.2 127.4 110.5 142.3 81.5 158.2 56.2 4500 80 132.4 127.7 146.9 103.7 163.5 78.2 128. ...

  • Trane Genius PKG-PRC007-EN - page 33

    33 PKG-PRC007-EN Performance Data Air Cooled 60 Hz T able PD-14 — Gross Cooling Capacities SRVE-125 Metric Ambient T emperature (°C) 29.5 35.0 Entering Wet Bulb T emperature (°C) Ent. 16.0 19.5 23.0 16.0 19.5 23.0 DB m3/h (ºC) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 38.6 31.7 43.1 24.5 48.0 17.1 37.3 32.4 41.7 23.9 46.3 16.5 7650 27 ...

  • Trane Genius PKG-PRC007-EN - page 34

    PKG-PRC007-EN 34 T able PD-15 — Gross Cooling Capacities SRVE-150 English Ambient T emperature (°F) 85 95 Entering Wet Bulb T emperature (°F) Ent. 61 67 73 61 67 73 DB CFM (ºF) TGC SH C TGC SHC TG C SHC TGC SHC TGC SHC TGC SHC 75 161.0 135.9 179.6 102.9 199.5 69.6 155.3 133.2 173.1 100.3 192.3 67.0 5400 80 163.6 159.3 179.5 129.6 199.4 96.2 15 ...

  • Trane Genius PKG-PRC007-EN - page 35

    35 PKG-PRC007-EN Performance Data Air Cooled 60 Hz T able PD-15 — Gross Cooling Capacities SRVE-150 Metric Ambient T emperature (°C) 29.5 35.0 Entering Wet Bulb T emperature (°C) Ent. 16.0 19.5 23.0 16.0 19.5 23.0 DB m3/h (ºC) TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC TGC SHC 24 47.2 39.8 52.6 30.1 58.5 20.4 45.5 39.0 50.7 29.4 56.3 19.6 9180 27 ...

  • Trane Genius PKG-PRC007-EN - page 36

    PKG-PRC007-EN 36 The Genius line offers two Control options: Standard Thermostat or Microprocessor Control. Standard Thermostat All units are supplied with a control thermostat as standard feature. This thermostat can be installed remotely or in the equipment, according to the needs of the client. Microprocessor Control The Microprocessor Control U ...

  • Trane Genius PKG-PRC007-EN - page 37

    37 PKG-PRC007-EN Electrical Data T able ED-1 — Genius – Electrical Features - SRVE/SIVE 050 Nominal Operation V alues Compressor Fan Motor Fan Motor Consumption Current Fan V oltage KW CNO KW CNO KW CNO KW A STD 220V 15.40 3.04 3.04 21.48 and 380V 4.74 8.92 0.83 1.76 0.83 1.76 6.40 12.44 Option 1 440V 7.70 1.52 1.52 10.74 220V 15.40 4.14 3.04 2 ...

  • Trane Genius PKG-PRC007-EN - page 38

    PKG-PRC007-EN 38 Electrical Data T able ED-2 — Genius – Electrical Features - SRVE/SIVE 050 Nominal Operation V alues Compressor Fan Motor Fan Motor Consumption Current Fan V oltage KW CNO KW CNO KW CNO KW A 220V 18.60 4.14 7.32 30.06 STD 380V 6.39 10.77 1.22 2.39 2.23 4.23 9.84 17.39 440V 9.30 2.07 3.65 15.02 220V 18.60 5.53 7.32 31.45 Option ...

  • Trane Genius PKG-PRC007-EN - page 39

    39 PKG-PRC007-EN Electrical Data T able ED-3 — Genius – Electrical Features - SRVE/SIVE 100 Nominal Operation V alues Compressor 1 Compressor 2 Fan Motor Fan Motor Consumption Current Fan V oltage KW CNO KW CNO KW CNO KW CNO KW A 220V 15.40 15.40 4.14 7.32 42.26 STD 380V 4.74 8.92 4.74 8.92 1.22 2.39 2.23 4.23 12.93 24.46 440V 7.70 7.70 2.07 3. ...

  • Trane Genius PKG-PRC007-EN - page 40

    PKG-PRC007-EN 40 Electrical Data T able ED-4 — Genius – Electrical Features - SRVE/SIVE 125 Nominal Operation V alues Compressor 1 Compressor 2 Fan Motor Fan Motor Consumption Current Fan V oltage KW CNO KW CNO KW CNO KW CNO KW A 220V 18.60 15.40 5.53 9.28 48.81 STD 380V 6.39 10.77 4.74 8.92 1.64 3.19 2.93 5.36 15.70 28.24 440V 9.30 7.70 2.76 4 ...

  • Trane Genius PKG-PRC007-EN - page 41

    41 PKG-PRC007-EN Electrical Data T able ED-5 — Genius – Electrical Features - SRVE/SIVE 150 Nominal Operation V alues Compressor 1 Compressor 2 Fan Motor Fan Motor Consumption Current Fan V oltage KW CNO KW CNO KW CNO KW CNO KW A 220V 18.60 18.60 7.32 11.61 56.13 STD 380V 6.39 10.77 6.39 10.77 2.23 4.23 3.54 6.70 18.55 32.47 440V 9.30 9.30 3.66 ...

  • Trane Genius PKG-PRC007-EN - page 42

    PKG-PRC007-EN 42 T able ED-6 — Genius – Electrical Features - SA VE 050 Nominal Operation V alues Compressor Fan Motor Consumption Current Fan V oltage KW CNO KW CNO KW A STD 220V 14.10 3.04 17.14 and 380V 4.17 8.16 0.83 1.76 5.00 9.92 Option 1 440V 7.05 1.52 8.57 220V 14.10 4.14 18.24 Option 2 380V 4.17 8.16 1.22 2.39 5.39 10.55 440V 7.05 2.07 ...

  • Trane Genius PKG-PRC007-EN - page 43

    43 PKG-PRC007-EN Electrical Data T able ED-7 — Genius – Electrical Features - SA VE 075 Nominal Operation V alues Compressor Fan Motor Consumption Current Fan V oltage KW CNO KW CNO KW A 220V 16.99 4.14 21.13 STD 380V 5.68 9.84 1.22 2.39 6.90 12.23 440V 8.50 2.07 10.57 220V 14.10 5.53 22.52 Option 1 380V 5.68 9.84 1.64 3.19 7.32 13.03 440V 8.50 ...

  • Trane Genius PKG-PRC007-EN - page 44

    PKG-PRC007-EN 44 T able ED-8 — Genius – Electrical Features - SA VE100 Nominal Operation V alues Compressor 1 Compressor 2 Fan Motor Consumption Current Fan V oltage KW CNO KW CNO KW CNO KW A 220V 14.10 14.10 4.14 32.34 STD 380V 4.17 8.16 4.17 8.16 1.22 2.39 9.56 18.71 440V 7.05 7.05 2.07 16.17 220V 14.10 14.10 5.53 33.73 Option 1 380V 4.17 8.1 ...

  • Trane Genius PKG-PRC007-EN - page 45

    45 PKG-PRC007-EN Electrical Data • T o know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option - evaporator fan motor -2 CV . • Option 1 - evaporator fan motor -3 CV . • Option 2 - ev ...

  • Trane Genius PKG-PRC007-EN - page 46

    PKG-PRC007-EN 46 Electrical Data • T o know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option - evaporator fan motor -3 CV . • Option 1 - evaporator fan motor -4 CV . • Option 2 - ev ...

  • Trane Genius PKG-PRC007-EN - page 47

    47 PKG-PRC007-EN Dimensions 01 - Plenum box with optional supply screen 02 - Resistor box for heating (optional) (control and power panel for external heating) 03 - Double [intake / exhaust] (evaporator) Centrifugal fan 04 - Supply motor 05 - Evaporating coil 06 - Return screen (optional) 07 - Filters 08 - Spacing for energy intake wire f 46.5 (rig ...

  • Trane Genius PKG-PRC007-EN - page 48

    PKG-PRC007-EN 48 01 - Plenum box with optional supply screen 02 - Resistor box for heating (optional) (control and power panel for external heating) 03 - Double [intake / exhaust] (evaporator) Centrifugal fan 04 - Supply motor 05 - Evaporating coil 06 - Return screen (optional) 07 - Filters 08 - Spacing for energy intake wire f 46.5 (right/left) 09 ...

  • Trane Genius PKG-PRC007-EN - page 49

    49 PKG-PRC007-EN Dimensions SIVE 01 - Plenum box with optional supply screen 02 - Resistor box for heating (optional) (control and power panel for external heating) 03 - Double [intake / exhaust] (evaporator) Centrifugal fan 04 - Supply motor 05 - Evaporating coil 06 - Return screen (optional) 07 - Filters 08 - Spacing for energy intake wire f 46.5 ...

  • Trane Genius PKG-PRC007-EN - page 50

    PKG-PRC007-EN 50 Dimensions CRCB 01 - Double [intake / exhaust] Centrifugal fan 02 - T erminal box 03 - Service panel 04 - Motor 05 - Condensing coil 06 - Spacing for ø 27 energy intake wire 07 - Refrigeration connections (only one setting) Model A B C D E F G H I J L M N P Q R ø L1 ø D1 ø L2 ø D2 050 39 25 35 12 16 – – 13 30 28 4 41 21 5 ...

  • Trane Genius PKG-PRC007-EN - page 51

    51 PKG-PRC007-EN Mechanical Specifi cations Cabinet Manufactured of galvanized steel plate, it is painted with anticorrosive primer and high resistance synthetic enamel. The cabinet is constructed with an bottom tray , structural laterals, front screen and cover and back cover . The remote condenser cabinet is painted with epoxy primer and high res ...

  • Trane Genius PKG-PRC007-EN - page 52

    The T rane Company 3600 Pammel Creek Road La Crosse, WI 54601-7599 www .trane.com An American Standard Company Since The T rane Company has a policy of continuous product improvement, it reserves the right to change design and specifications without notice. Literature Order Number File Number Supersedes Stocking Location Regulating points for high ...

Fabbricante Trane Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoTrane Genius PKG-PRC007-EN possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Trane
- manuali per l’uso Genius PKG-PRC007-EN
- schede prodotto Trane
- opuscoli
- o etichette energetiche Trane Genius PKG-PRC007-EN
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Trane Genius PKG-PRC007-EN.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Trane Genius PKG-PRC007-EN, manuali di manutenzione, brevi manuali o manuali utente Trane Genius PKG-PRC007-EN. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Trane Genius PKG-PRC007-EN.

Manuale completo del dispositivo Trane Genius PKG-PRC007-EN, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Trane Genius PKG-PRC007-EN dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Trane Genius PKG-PRC007-EN.

Il manuale per l’uso completo Trane, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Trane Genius PKG-PRC007-EN - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Trane Genius PKG-PRC007-EN, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Trane Genius PKG-PRC007-EN che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Trane Genius PKG-PRC007-EN - che ci dovrebbe aiutare nei primi passi durante l'uso Trane Genius PKG-PRC007-EN
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Trane Genius PKG-PRC007-EN
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Trane Genius PKG-PRC007-EN in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Trane Genius PKG-PRC007-EN?

Utilizza il modulo sottostante

Se non hai risolto il problema con Trane Genius PKG-PRC007-EN con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Trane Genius PKG-PRC007-EN è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)