    DIRECT -VENT FIREPLACE ® OWNER’S OPERA TION AND INST ALLA TION MANUAL ® BDV34N(A) AND BDV34P(A) Save this manual for future reference. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch • Do not use any phone in your building. • Immediately call your gas supplier from a ...

  • Desa BDV34N(A) - page 2

    2 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not con vertible for use with other gases unless a certif ied kit is used. 2. For propane fireplace, do not place pro- pane/LP supply tank(s) inside any structure. Locate ...

  • Desa BDV34N(A) - page 3

    3 105453 OWNER’S MANUAL PRODUCT IDENTIFICA TION Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1 , also known as NFPA 54* (USA) or the current CAN/CGA-B149[.1 or .2] Installation Codes (Canada) . *Available from: American National Standards Institute, Inc ...

  • Desa BDV34N(A) - page 4

    4 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® Fireplace size D x FW x RW 34" 18 1 / 2 " 34" 14" PRE-INST ALLA TION PREP ARA TION LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your Vanguard direct-vent fireplace. Make sure that rafters and wall studs are not in the way of the vent ...

  • Desa BDV34N(A) - page 5

    5 105453 OWNER’S MANUAL 29" 13" 12 5 / 8 " 34 1 / 4 " 34 3 / 4 " 58" 9 1 / 4 " 41" Nailing T abs PRE-INST ALLA TION PREP ARA TION Continued Figure 6 - Framing Clearances for Corner Installation LOCATION OF VENT TERMINATION When locating vent termination, it is impor- tant to observe the minimum clearances s ...

  • Desa BDV34N(A) - page 6

    6 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (305mm) minimum] ...

  • Desa BDV34N(A) - page 7

    7 105453 OWNER’S MANUAL WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of im- properly installed and maintained venting system could result in serious injury, property damage or loss of life. WARNING: Seal all of ...

  • Desa BDV34N(A) - page 8

    8 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will tak e. Note: The location of the horizontal vent termination on the exterior w all must meet all local and national building codes and must not be easily blocked or obstructed. Snorkel terminations are a ...

  • Desa BDV34N(A) - page 9

    9 105453 OWNER’S MANUAL VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1 / 2 " (190mm) V ent Opening Combustible W all V ent Opening Noncombustible W all Figure 12 - Vent Opening Requirements Continued 3. Attach v ent pipe assembly to the fire- place. Set fireplace in front of it’ s per- manent locati ...

  • Desa BDV34N(A) - page 10

    10 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® VENTING INST ALLA TION Continued UP Horizontal V enting V ertical (V) Horizontal (H) 37" min. 10" max. Figure 16 - Horizontal Termination Configuration for Rigid Venting Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One 90 ° Elbow Figure 18 - Horizontal Te ...

  • Desa BDV34N(A) - page 11

    11 105453 OWNER’S MANUAL VENTING INST ALLA TION Continued UP V enting with T wo 90 ° Elbo ws V ertical (V) Horizontal (H 1 ) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' min. 20' max. 20' max. 8' max ...

  • Desa BDV34N(A) - page 12

    12 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® Figure 22 - Installing Firestop If area above is not a room, install firestop below framed hole. If area above is a room, install firestop above framed hole. INSTALLATION FOR VERTICAL TERMINATION 1. Determine the route your vertical vent- ing will take. If ceiling joists, roof rafters, or othe ...

  • Desa BDV34N(A) - page 13

    13 105453 OWNER’S MANUAL VENTING INST ALLA TION Continued Continued Figure 23 - Cathedral Ceiling Support Box Installation Non-hardening Mastic under all edges of support box before nailing Figure 24 - Installed Cathedral Ceiling Support Box Vertical Termination Configurations Figures 25 through 28 show four different configurations for vertical ...

  • Desa BDV34N(A) - page 14

    14 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® V er tical V enting V = 30' max. Figure 28 - Vertical Rigid Venting Configuration With No Horizontal Run VENTING INST ALLA TION Continued V enting with T wo 9 0 ° E lbows V ertical (V 1 ) Horizontal (H) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8&apo ...

  • Desa BDV34N(A) - page 15

    15 105453 OWNER’S MANUAL VENTING INST ALLA TION Continued HIGH ALTITUDE INSTALLATION Your Vanguard direct-vent fireplace has been AGA tested and approved for eleva- tions from 0-2000 feet and CGA certified for elevations from 0-4500 feet. When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the inp ...

  • Desa BDV34N(A) - page 16

    16 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® INSTALLING OPTIONAL BLOWER ACCESSORY IMPORTANT : For clarity, gas valve assem- bly and grate/burner assembly are not shown in Figures 30 through 33 , page 17. They will, however, be in your fireplace when you are installing the blower. Also for clarity the firebox is shown with dotted lines. 1 ...

  • Desa BDV34N(A) - page 17

    17 105453 OWNER’S MANUAL FIREPLACE INST ALLA TION Continued WARNING: Never touch the blower wheel while in operation. 10 . Peel off the backing pa per and stick the supplied wiring diagram decal on the fir ebox bottom approximately 3" to the right of the blow er speed control bracket (see Figure 33). WARNING: Failure to position the parts in ...

  • Desa BDV34N(A) - page 18

    18 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® Figure 35 - Gas Connection * The A.G.A. design-certified manual shutoff valve may be supplied with the appliance or you can purchase it from your dealer. CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use ...

  • Desa BDV34N(A) - page 19

    19 105453 OWNER’S MANUAL Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its indi vidual manual shutoff v alve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damag e fireplace gas regulator . 2. Cap of f open end of gas pipe where manual shutof f v ...

  • Desa BDV34N(A) - page 20

    20 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® FIREPLACE INST ALLA TION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close manual shutoff v alve (see Fig- ure 37). 2. Pressurize supply piping system by ei- ther opening propane supply tank v alve for propane gas fireplace or opening main gas valv e located on or near ...

  • Desa BDV34N(A) - page 21

    21 105453 OWNER’S MANUAL REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this fireplace with a broken glass door panel or without the glass door panel securely in place. For re- placement part information see Replacement Parts , page 30. 1. Remove the upper louv er panel by lift- ing upward and out (see Figure 44). 2. Remove the scr ews fro ...

  • Desa BDV34N(A) - page 22

    22 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® INSTALLING OPTIONAL BRICK LINER D8037 WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before installing brick liner. This brick liner kit is optional. You may purchase brick liner from your local dealer or see Accessories , page 32. CAUTION: Always handle bric ...

  • Desa BDV34N(A) - page 23

    23 105453 OWNER’S MANUAL 6. Pull ember material apart into pieces no larger than a dime. Place these pieces loosely and sparingly directly onto the exposed section of the front bur ner and along the space betw een the burner and gra te prongs (see Figure 52). This will create the glo wing ember ap- pearance as the flame touches the em- ber materi ...

  • Desa BDV34N(A) - page 24

    24 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® O F F P I L O T O N L O I H OPERA TING FIREPLACE WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follo w ...

  • Desa BDV34N(A) - page 25

    25 105453 OWNER’S MANUAL O F F P I L O T O N L O I H ON OFF REMOTE OFF ON INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot i ...

  • Desa BDV34N(A) - page 26

    26 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® PILOT AND BURNERS • Remove ember material before cleaning burners and r eplace when cleaning is complete. • Burner and controls should be cleaned with compressed air to remov e dust, dirt, or lint. • Use a vacuum cleaner or small, soft bristled brush to remov e e xcess dust, dirt, or lin ...

  • Desa BDV34N(A) - page 27

    27 105453 OWNER’S MANUAL TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean pilot. This can damage pilot unit. POSSIBLE CAUSE 1. Igni ...

  • Desa BDV34N(A) - page 28

    28 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit Glass soots Fireplace produces a clicking/ticking noise just after burners ar ...

  • Desa BDV34N(A) - page 29

    29 105453 OWNER’S MANUAL www.desatech.com TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • ...

  • Desa BDV34N(A) - page 30

    30 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® SER VICE HINTS When Gas Pressure Is Too Low: • pilot will not stay lit • burners will hav e delayed ignition • fireplace will not produce specif ied heat • propane/LP gas supply might be lo w (propane units only) When Gas Quality Is Bad: • pilot will not stay lit • burners will pro ...

  • Desa BDV34N(A) - page 31

    31 105453 OWNER’S MANUAL SPECIFICA TIONS BDV34N(A) BDV34P(A) 15,000/21,000 Btu/hr 16,000/20,000 Btu/hr Gas Type Natural Propane Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.c. Dimension, Inches/mm (HxWxD) Fireplace 33" x 34" x 18 1 / 2 " 33" x 3 ...

  • Desa BDV34N(A) - page 32

    32 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® MANUAL BLOWER KIT GA3700 Manual-variable control blower accessory for the B DV Series fireplaces. THERMOSTATICALLY- CONTROLLED BLOWER KIT DA3610T Provides better heat distribution. Blower turns off and on automatically, as needed. Complete installation and operation instruc- tions included in ...

  • Desa BDV34N(A) - page 33

    33 105453 OWNER’S MANUAL ACCESSORIES Continued DUPLEX OUTLET KIT GA3555 (NOT SHOWN) For built-in installation when accessory blowers are used. BRASS PERIMETER TRIM KIT - GA6090 (Not Shown) Optional three sided brass trim kit covers unfinished edges around fireplace. Provides a finished appearance with the class of brass. BRASS LOUVER KIT D6034 (N ...

  • Desa BDV34N(A) - page 34

    34 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® ILLUSTRA TED PA R T S BREAKDOWN BDV34N(A) 1 2 3 4 6 7 7 8 9 10 1 1 (Included in Hardware Pack) 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31-3 31-2 31-4 31-1 32 33 32 34 46 5 5 5 35 40 41 32 42 43 44 38 6 37 36 39 6 45 ...

  • Desa BDV34N(A) - page 35

    35 105453 OWNER’S MANUAL P ARTS LIST DIRECT-VENT FIREPLACE BDV34N(A) This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 104445-01 Top Outer Casing 1 2 105278-01 Outer Casing 1 3 105297-01 Bottom O ...

  • Desa BDV34N(A) - page 36

    36 105453 DIRECT -VENT FIREPLACE (NA TURAL/PROP ANE) ® ILLUSTRA TED PA R T S BREAKDOWN BDV34P(A) 1 2 3 4 6 7 7 8 9 10 1 1 (Included in Hardware Pack) 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28 29 30 31-3 31-2 31-4 31-1 32 33 32 34 46 5 5 5 35 40 41 32 42 43 44 38 6 37 36 39 6 45 ...

  • Desa BDV34N(A) - page 37

    37 105453 OWNER’S MANUAL P ARTS LIST DIRECT-VENT FIREPLACE BDV34P(A) This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 104445-01 Top Outer Casing 1 2 105278-01 Outer Casing 1 3 105297-01 Bottom O ...

  • Desa BDV34N(A) - page 38

    LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the ...

Fabbricante Desa Categoria Outdoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoDesa BDV34N(A) possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Desa
- manuali per l’uso BDV34N(A)
- schede prodotto Desa
- opuscoli
- o etichette energetiche Desa BDV34N(A)
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Desa BDV34N(A).

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Desa BDV34N(A), manuali di manutenzione, brevi manuali o manuali utente Desa BDV34N(A). A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Desa BDV34N(A).

Manuali per l’uso simili

Manuale completo del dispositivo Desa BDV34N(A), come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Desa BDV34N(A) dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Desa BDV34N(A).

Il manuale per l’uso completo Desa, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Desa BDV34N(A) - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Desa BDV34N(A), FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Desa BDV34N(A) che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Desa BDV34N(A) - che ci dovrebbe aiutare nei primi passi durante l'uso Desa BDV34N(A)
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Desa BDV34N(A)
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Desa BDV34N(A) in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Desa BDV34N(A)?

Utilizza il modulo sottostante

Se non hai risolto il problema con Desa BDV34N(A) con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Desa BDV34N(A) è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)