    Installation and Operating Instructions for Gas Log Heaters Models: UVHK23MP , UVHK29MN, UVHK31MP , UVHK36MN Mod els wi th “N” af ter th e m ode l n umb er use na tur al gas ; m ode ls wit h “ P” aft er the mo del nu mbe r u se pro pan e ( LP) ga s. This appliance operates as an unvented room heat- er certified under ANSI Z21.1 1.2b-2004 w ...

  • CFM UVHK23MP - page 2

    2 20008056 Important Information .................................................................................................................. 3 Important Safeguards ............................................................................................................... 4 Installation Requirements ....................................... ...

  • CFM UVHK23MP - page 3

    3 20008056 Important Information W ARNING: Any change to this heater or its con- trols can be dangerous. In the Commonwealth of Massachusetts, all gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber . • Due to high temperatures, the appliance should be lo- cated out of traffic and away fr ...

  • CFM UVHK23MP - page 4

    4 20008056 The National Fuel Gas Code, ANSI Z223.1/NFP A 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8m 3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hou ...

  • CFM UVHK23MP - page 5

    5 20008056 W ARNING This appliance is for installation in a solid-fuel burning masonry , fireplace with a working flue, a U.L.-127 listed manufactured solid-fuel burn- ing fireplace, in any Majestic ventless firebox, or in any listed ventless firebox enclosure certified to I.A.S. U.S. Requirement 2-97 or ANSI Z21.91. NOTICE This is an unvente ...

  • CFM UVHK23MP - page 6

    6 20008056 W ARNING: Refer to the above table to ensure that your log set is certified to be used in the CFM Corporation V ent-Free firebox you have purchased. BR/BC and SHR models are designed as wood/solid fuel fireplaces. These wood-burning models must be installed as a wood-burning unit including chimney and termination cap before the install ...

  • CFM UVHK23MP - page 7

    7 20008056 Provisions for Adequate Combustion and V entilation Air W ARNING: This heater shall not be installed in a confined space or unusually tight construc- tion unless provisions are provided for adequate combustion and ventilation air . T oday’s homes are built more energy efficient than ever . New materials, increased insulation and new ...

  • CFM UVHK23MP - page 8

    8 20008056 L W D T104 flue damper 10/27/03 djt Flue Damper Closed for Unvented Operation and Maximum Heat Output Flue Damper Locked Open to a Minimum V enting Area of 34 sq. in. (for areas where unvented products are not permitted) NOTE: For round flue opening minimum flue diameter (D) - 7”. For square or rectangular flue opening, length x ...

  • CFM UVHK23MP - page 9

    9 20008056 Installation Unpacking Open the carton and remove the logs and the chassis. Remove each of the logs by gripping at either end of the log while avoid- ing any undue pressure. Please note that the logs have been marked for positive identification. The carton for all models contains the following: chassis, front log (#1), rear log (#2), to ...

  • CFM UVHK23MP - page 10

    10 20008056 42" 16" T105 Minimum clearance to walls & ceiling 10/27/03 djt Fig. 4A Minimum clearance to wall and ceiling. 10" 8" 6" 1 ¹⁄₈ " 10" Min. 15" Min. 19" Min. 23" Min. 27" Min. T106 Mantel clearance no canopy 10/27/03 djt Heat Resistant Material No Canopy Used Fig. 4B Man ...

  • CFM UVHK23MP - page 11

    1 1 20008056 Gas Connection Check Gas T ype. Use only the gas type indicated on the heater ’s rating plate. If the gas type indicated on the plate is not your type of gas supply , DO NOT INST ALL. Contact your dealer for the proper model. W ARNING DANGER OF PROPERTY DAMAGE, BODIL Y INJUR Y OR DEA TH. Make sure the heater is equipped to operate on ...

  • CFM UVHK23MP - page 12

    12 20008056 NOTE: T o determine the size of the branch gas line from the main gas line to the fireplace, enter the tables below (for iron pipe or copper tubing) using the distance from the gas meter or second stage regulator to the furthest appliance on the gas system. Select a pipe or tube diameter which has enough capacity to meet the maximum in ...

  • CFM UVHK23MP - page 13

    13 20008056 For Y our Safety , Read Before Lighting W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE OPERA TION smell ...

  • CFM UVHK23MP - page 14

    14 20008056 Flame Check A periodic visual check of the flames should be made. The pilot flame should always be present when the appliance is in opera - tion. (Fig. 10) In normal operation (at full rate for approximately 15 minutes) the following flame appearance should be observed: Managing Heat Output When installed in a wood burning fireplace ...

  • CFM UVHK23MP - page 15

    15 20008056 Positioning Logs The logs must be positioned ONL Y as illustrated in Figures 12, 13 and 14 • Position the front log so that the large notch in the underside of the right end of the log fits securely and rests on the sheet metal control cover as shown in Figure 15. The front right end of the log has a ‘V’ shaped notch to touch the ...

  • CFM UVHK23MP - page 16

    16 20008056 Charred Oak Logset Fig. 13 Charred oak logset positions. W ARNING: Failure to position the parts in accordance with this diagram or failure to use only parts specifically ap - proved with this heater , may result in property damage or personal injury . Do not alter the logs! Charred Oak Logset Fig. 14 Charred oak logset correct potitio ...

  • CFM UVHK23MP - page 17

    17 20008056 T100 log notch on valve cover 10/15/03 djt V alve Cover T100 Fig. 15 Position log so notch fits securely and rests on valve cover . T101 secure front log 10/15/03 djt Front Log End Bar Should Fit in V -Shaped Depression in the Bark T101 Fig. 16 Front end of frontlog should touch grate bar . T124 Side view logset 10/28/03 djt Log ...

  • CFM UVHK23MP - page 18

    18 20008056 Servicing Repair and replacement work should only be done by a quali- fied service technician. Always shut off the gas supply and make sure the appliance is cool before beginning any service operation. Always check for gas leaks after servicing. Repair Parts Always include the correct name, part number , model number , control type and ...

  • CFM UVHK23MP - page 19

    19 20008056 LIMITED 2/20 YEAR W ARRANTY For Majestic Fireplaces V ent-Free Gas Appliances CFM Corporation (Company) extends the warranties speci- fied in paragraphs A and B below with respect to its Majestic Fireplaces Decorative Gas Appliances (the “Gas Appliance”), including the CFM Corporation supplied accessories and com- ponents referred ...

  • CFM UVHK23MP - page 20

    410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation ...

Fabbricante CFM Categoria Fan

I documenti che otteniamo dal fabbricante del dispositivoCFM UVHK23MP possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici CFM
- manuali per l’uso UVHK23MP
- schede prodotto CFM
- opuscoli
- o etichette energetiche CFM UVHK23MP
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso CFM UVHK23MP.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione CFM UVHK23MP, manuali di manutenzione, brevi manuali o manuali utente CFM UVHK23MP. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto CFM UVHK23MP.

Manuali per l’uso simili

Manuale completo del dispositivo CFM UVHK23MP, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare CFM UVHK23MP dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti CFM UVHK23MP.

Il manuale per l’uso completo CFM, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale CFM UVHK23MP - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice CFM UVHK23MP, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per CFM UVHK23MP che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo CFM UVHK23MP - che ci dovrebbe aiutare nei primi passi durante l'uso CFM UVHK23MP
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del CFM UVHK23MP
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio CFM UVHK23MP in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su CFM UVHK23MP?

Utilizza il modulo sottostante

Se non hai risolto il problema con CFM UVHK23MP con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con CFM UVHK23MP è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)