Manuale per l’uso American Power Conversion 5000VA 5U

14 pagine 1.44 mb
Scarica

Vai alla pagina of 14

Summary
  • American Power Conversion 5000VA 5U - page 1

    990-1139, 3/02 User’s Manual English Smart Smart Smart Smart- - - -UP S UPS UPS UPS ® 5000VA 5U Rack Mount XL 208VAC/230VA C Uninterr uptible Pow er Supply ...

  • American Power Conversion 5000VA 5U - page 2

    ...

  • American Power Conversion 5000VA 5U - page 3

    1 Introduction The APC Un i nterru ptible Power Supply (UPS) is design ed to prevent blackou t s, brown o uts, sags , and surges from reaching your computer and other valuable electronic equipment. The UPS filters small utility line fluctuations and isolates your equipment from large disturbances b y internally dis- connecting from the utility lin ...

  • American Power Conversion 5000VA 5U - page 4

    2 Mounting the UPS in the Rack Hardwire the Ele ctrical Connection (230V M odels Only) Verify that t he supply line contains a 2 5 Amp circuit breaker BEFORE hardw iring the UPS. Batteries are installed in the UPS upon hardwiring co mpletion. Incorporate an easy access disconnect device in the fi xed w iring design. 1. Select the appropriate wi re ...

  • American Power Conversion 5000VA 5U - page 5

    3 Connecting Equipment and Power to the UPS S MART - UPS R EAR P ANEL 1. Connect equi pment to the UPS. 2. Add any option al accessories to the Smart- Slot. The UPS is shi pped wi th the APC Netwo rk M anage- ment card pre- installed. Refe r to the documentation in the literature kit an d/or CD-ROM provided. 3. 208V Models O nly: Using a power cord ...

  • American Power Conversion 5000VA 5U - page 6

    4 2: O PERA TION I NDICATORS AND C ONTROLS ON THE S MART -UPS S MART - UPS F RONT P ANEL Power On Power Off Load Battery Charge Online The online LED illuminates when the UPS is suppl ying utility power to the connected equ ipment. AVR Tr im This LED illuminates to i ndicate the UPS is compensatin g for a high utility volta ge. AVR Boost This LED i ...

  • American Power Conversion 5000VA 5U - page 7

    5 Automatic Self- Test The UPS performs a self-test automatically when turned on, and every tw o weeks thereafter (by default). During the self-t est, the UPS briefly operates the con nected equipment on bat- tery. If the UPS fails the self-test, the repl ace ba ttery LED illuminates and im- mediately returns to online operation. The connected equi ...

  • American Power Conversion 5000VA 5U - page 8

    6 3: U SER C ONFIGU RAB LE I TEMS N OTE : S ETTINGS ARE MADE THROUGH SUPP LIED P OWER C HUTE SOF TWARE OR OP TIONAL S MAR T S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Automa tic Self-Test Every 14 days (336 hours) Every 7 days (168 hours) , On Startup Only, No Self-Te st This func tion sets the inter ...

  • American Power Conversion 5000VA 5U - page 9

    7 N OTE : S ETTINGS ARE MADE THROUGH SUPP LIED P OWER C HUTE SOF TWARE OR OP TIONAL S MAR T S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Battery Warning . PowerChute in terface softw are provides auto- matic, unatte nded shut- down w hen approx imately two m inutes (by default) of battery operated ...

  • American Power Conversion 5000VA 5U - page 10

    8 4: S TO R AG E , M A INTENA NCE , AND T RANSPORTING Storage Store the UPS covered and f la t (rack mount orien tatio n) in a cool, dry location, w ith the batteries full y cha rged . At -15 t o +30 ° C (+5 to +86 ° F), ch arge the UP S battery every six m onths. At +30 t o +45 ° C (+86 to + 113 ° F), charge the UPS battery every three months ...

  • American Power Conversion 5000VA 5U - page 11

    9 5: T ROUBLESHOOTING Use the chart belo w to solve minor Smart-UPS installation and operation problems. Re fer to the APC web site, www.apc.com , for assistance with complex UPS problem s. P ROBLEM AND P OSSI BLE C AUSE S OLUTION UPS WILL NOT TURN ON Batt ery not conn ected proper ly. Check that th e batt ery con nect or is fu lly engaged . butt o ...

  • American Power Conversion 5000VA 5U - page 12

    10 P ROBLEM AND P OSSI BLE C AUSE S OLUTION T HE OVERLOAD LED IS ILLUMINA TED AND THE UPS EM ITS A SUSTAINED ALARM T ONE The UPS is over load ed. The c onn ected equ ip ment exc eeds the sp eci fied “m axi mum load ” as def in ed in Spec ific ations at the A PC web site , www .apc.com . The alarm re mains on u ntil the o verl oad is r emove d. ...

  • American Power Conversion 5000VA 5U - page 13

    11 P ROBLEM AND P OSSI BLE C AUSE S OLUTION D IAGNOSTIC U TI LITY V OLTA GE F EATURE Utility Volta ge The UPS has a diagnosti c feature that dis plays the util ity v oltage. Pl ug the U PS into t he normal utility power . Press a nd h old the button t o view th e utilit y voltage b ar graph displa y. Afte r a few seconds the five -LED , Battery Cha ...

  • American Power Conversion 5000VA 5U - page 14

    12 6: R EGULA TOR Y A ND W AR R ANT Y I NFORMA T ION Regulatory Agency Approvals and Radio Frequency Warnings 208V MOD EL S 230V MOD EL S Declaration of Conformity Li mit ed Wa rra nty American Power Convers ion (APC) warrants its products to be free from defects in materials and workmans hip for a period of two year s from the date of purc hase. I ...

Fabbricante American Power Conversion Categoria Power Supply

I documenti che otteniamo dal fabbricante del dispositivoAmerican Power Conversion 5000VA 5U possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici American Power Conversion
- manuali per l’uso 5000VA 5U
- schede prodotto American Power Conversion
- opuscoli
- o etichette energetiche American Power Conversion 5000VA 5U
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso American Power Conversion 5000VA 5U.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione American Power Conversion 5000VA 5U, manuali di manutenzione, brevi manuali o manuali utente American Power Conversion 5000VA 5U. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto American Power Conversion 5000VA 5U.

Manuale completo del dispositivo American Power Conversion 5000VA 5U, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare American Power Conversion 5000VA 5U dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti American Power Conversion 5000VA 5U.

Il manuale per l’uso completo American Power Conversion, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale American Power Conversion 5000VA 5U - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice American Power Conversion 5000VA 5U, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per American Power Conversion 5000VA 5U che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo American Power Conversion 5000VA 5U - che ci dovrebbe aiutare nei primi passi durante l'uso American Power Conversion 5000VA 5U
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del American Power Conversion 5000VA 5U
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio American Power Conversion 5000VA 5U in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su American Power Conversion 5000VA 5U?

Utilizza il modulo sottostante

Se non hai risolto il problema con American Power Conversion 5000VA 5U con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con American Power Conversion 5000VA 5U è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)