    Relay PCA P/N 04523 Addendum to M100E, M200E and M400E Operator Manuals © TELEDYNE INSTRUMENTS ADVANC ED POLLUTION INSTRUMENTATION (T-API) 9480 CARROLL PARK DRI VE SAN DIEGO, CA 92121-52 01 USA Toll-free Phone: 800-324-5 190 Phone: 858-657-9 800 Fax: 858-657-9 816 Email: api-sales@teledyne.c om Website: http://www.teledyne-api.com/ 05118 Rev B3 DC ...

  • Teledyne M100E - page 2

    THIS PAGE INTENTIONALLY BLANK ...

  • Teledyne M100E - page 3

    Relay PCA 0452 3 Addendum to E-Series Operator Manuals SAFETY MESSAGES For general safety information please refer to your M100E/M200 E/M400E operato r’s manual. CAUTION Never disconnect electronic cir c uit boards, wiring harnesses or electroni c subassemblies while the unit is under power. Printed circuit assemblies (PCAs) ar e sensitive to ele ...

  • Teledyne M100E - page 4

    Addendum to E-Series Operator Manuals Relay PCA 0452 3 ii 05118 Rev B3 THIS PAGE INTENTIONALLY BLANK ...

  • Teledyne M100E - page 5

    Relay PCA 0452 3 Addendum to E-Series Operator Manuals TABLE OF CONTENTS 1. INTROD UCTION ................................................................................................................ ........... 1 1.1. What’s the Same ........................................................................................................... .. ...

  • Teledyne M100E - page 6

    Addendum to E-Series Operator Manuals Relay PCA 0452 3 ii 05118 Rev B3 THIS PAGE INTENTIONALLY BLANK ...

  • Teledyne M100E - page 7

    Relay PCA 0452 3 Addendum to E-Series Operator Manuals 1. INTRODUCTION This addendum documen t s a recent upgrade to the relay card installe d in some of the M100E, M200E and M400E series analyzers. S pecifically, a new relay PCA design, P/N 04523 replaces P/N 03955 and all of its versions in the following instruments. It also corrects several erro ...

  • Teledyne M100E - page 8

    Addendum to E-Series Operator Manuals Relay PCA 0452 3 1.2. What’s Different The major differences between the Relay PC A 04523 and Relay PCA 0 3955 are:  On instruments wi th internal pumps, t he pump is now confi gured for use with 110 VAC, 60 Hz vs. 220 VAC, 50 Hz operation by a set of configuration jumpers on the Relay PCA. Previously a se ...

  • Teledyne M100E - page 9

    Relay PCA 0452 3 Addendum to E-Series Operator Manuals There are two versions of the new relay card. Table 1-1 above cross references the PCA version with the various E-seri es analyzer models. 1.3.1. Version 045230200 This is the most commonly u sed version of the Rela y PCA. It includes a bank of solid state AC relays. This version is in stalled ...

  • Teledyne M100E - page 10

    Addendum to E-Series Operator Manuals Relay PCA 0452 3 USER NOTES: 4 05118 Rev B3 ...

  • Teledyne M100E - page 11

    Relay PCA 0452 3 Addendum to E-Series Operator Manuals 2. OPERATION AND CONFIGURATION 2.1. Power Distribution SENSOR SUITES LOGIC DEVI CES (e. g . C P U , I 2 C bus, Keyboard, Di spl ay, MotherBoar d, e tc. ) RELAY PCA ON / OF F SWITCH PS 2 (+12 VDC) OPTI ONAL VALVES (e.g. S a m ple /Ca l, Zero/Spans , etc .) MODEL S PEC IF I C VALVES (e.g. M /R V ...

  • Teledyne M100E - page 12

    Addendum to E-Series Operator Manuals Relay PCA 0452 3 JP2 Main AC Hea ter Configuration JP6 IZS Perm eatio n Tu be Heater an d O 2 Sensor Connecti on. (optional) JP7 Pump Configuratio n Figure 2-2: Location of AC power Configuration Jumpers There are several changes between the Relay PCA 04523 and previous version regarding AC power configuration ...

  • Teledyne M100E - page 13

    Relay PCA 0452 3 Addendum to E-Series Operator Manuals 2.1.1.1. AC configuration – Internal Pump (JP7) AC power configur at ion for internal pumps is set u sing Jumper set JP7 (see F igu re 1- 1 for the location of JP7). Table 2-1: AC Power Confi guration for Internal P umps (JP7) LINE POWER LINE FREQUENCY JUMPER COLOR FUNCTION JUMPER BETWEEN PIN ...

  • Teledyne M100E - page 14

    Addendum to E-Series Operator Manuals Relay PCA 0452 3 2.1.1.2. AC Configuration – Standard Heaters (JP2) Power configuration for the AC the standard heat ers is set using Jumper set JP2 (see Figure 1-1 for the location of JP 2). Table 2 -2: Power Conf iguratio n for Standar d AC Heater s (JP2) LINE VOLTAGE JUMPER COLOR HEATER(S) MODEL’S USED O ...

  • Teledyne M100E - page 15

    Relay PCA 0452 3 Addendum to E-Series Operator Manuals 2.1.1.3. AC Configuration –Heaters for Option Packages (JP6) Both the IZS valve option or an O 2 sensor options include AC heat ers that maintain an opti mum operating temperature for key comp onents of those option s. Jumper set JP6 is used to connect the heaters associated with those option ...

  • Teledyne M100E - page 16

    Addendum to E-Series Operator Manuals Relay PCA 0452 3 2.3. Status LEDs & Watch Dog Circuitry Like the previous versi on, the status LED’s on the Relay P CA 04523 includes thirteen LEDs that indicate the status of th e analyzer’s heaters, val ves and other general operating conditions. Since the functions represented by these LED di ffers f ...

  • Teledyne M100E - page 17

    Relay PCA 0452 3 Addendum to E-Series Operator Manuals 2.4. Heater Control Loop T he rm isto r(s) – Low T em perature Sensing : (e.g. Sample Cham ber and Reaction Cell t emperatures) RELAY PCA DC Cont rol Logic Soli d St at e AC R elays Pream pli fiers and Signal Condit i oni ng MOTHER BOARD A/ D Converter (V/F ) CPU Themocouple(s) (High Temperat ...

  • Teledyne M100E - page 18

    Addendum to E-Series Operator Manuals Relay PCA 0452 3 2.4.1. Thermocouple Inputs and Configuration Jumper (JP5) Although the 04523 relay PCA supports two ther mocouple inputs, the current M100E/M200E series analyzers only ut ilize one and the M 400E se ries analyzers none. By default, this singl e thermocouple input is plu gged into the TC1 inpu t ...

  • Teledyne M100E - page 19

    Relay PCA 0452 3 Addendum to E-Series Operator Manuals Input Gain Se lector 1 – 11 Type J Compensation 4 – 14 Output Scale Selector 2 – 12 Type J Compensation 3 – 13 Termination Selec tor 5 – 15 TC1 TC2 Input Gain Selector 6 – 16 Type J Compensa tion 9 – 19 Output Scale Selector 7 – 17 Type J Compensa tion 8 – 18 Te r m i nat io n ...

  • Teledyne M100E - page 20

    Addendum to E-Series Operator Manuals Relay PCA 0452 3 2.5. DC Power Supply Test Points The tables defining the names and functions of th e DC power test point th at appear in Chapter 11 of some revisions of the M100E/M200E/M400E op erator’s manual are incorrect. The following tables show the correct information. Table 2-5: DC Power Test P oint a ...

  • Teledyne M100E - page 21

    Relay PCA 0452 3 Addendum to E-Series Operator Manuals 3. TROUBLE SHOOTING AND REPAIR General Trouble shooting hints for the relay PCA are the same as described for the previous versions for the PCA. See Chapter 11 of yo ur M100 E/M200E/M400E operator’s manual for more information. 3.1. Removing / Replacing the Relay PCA from the Instrument The R ...

  • Teledyne M100E - page 22

    Addendum to E-Series Operator Manuals Relay PCA 0452 3 4. SCHEMATICS AND SPARE PARTS FOR RELAY PCA P/N 04523 Table 4-1: List of Spar e Part s DOCUMENT # DOCUMENT TITLE RL0000015 Relay, DPDT, AC, Solid State, E-Series 041520500 Module, Relay PCA & Power Supply Table 4-2: List of Included El ectronic Schematics DOCUMENT # DOCUMENT TITLE 04524 PCA ...

Fabbricante Teledyne Categoria Marine Radio

I documenti che otteniamo dal fabbricante del dispositivoTeledyne M100E possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Teledyne
- manuali per l’uso M100E
- schede prodotto Teledyne
- opuscoli
- o etichette energetiche Teledyne M100E
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Teledyne M100E.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Teledyne M100E, manuali di manutenzione, brevi manuali o manuali utente Teledyne M100E. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Teledyne M100E.

Manuali per l’uso simili

Manuale completo del dispositivo Teledyne M100E, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Teledyne M100E dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Teledyne M100E.

Il manuale per l’uso completo Teledyne, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Teledyne M100E - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Teledyne M100E, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Teledyne M100E che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Teledyne M100E - che ci dovrebbe aiutare nei primi passi durante l'uso Teledyne M100E
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Teledyne M100E
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Teledyne M100E in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Teledyne M100E?

Utilizza il modulo sottostante

Se non hai risolto il problema con Teledyne M100E con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Teledyne M100E è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)