    IS3480 QuantumE QuantumT 3580 Fusion 3780 Orbit 7120/7180 Solaris 7820 Quick Start Guide Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per l'italiano. Gehe zu www.honeywellaidc.com für Deutsch. Ir a www.honeywellaidc.com para español. Para Português, acesse www.honeywellaidc.com.br . Перейти на ру? ...

  • Honeywell 7820 - page 2

    ...

  • Honeywell 7820 - page 3

    1 Getting Started Turn off the computer’s power before connecting the scanner, then power up the computer once the scanner is fully connected. Scanner Host P orts QuantumT 3580 Fusion 3780 IS3480 QuantumE Orbit 7120/7180 Solaris 7820 ...

  • Honeywell 7820 - page 4

    2 Connecting the Scanner Serial (RS232) Ke yboard We d g e optional adapter cable Connect to scanner’s host port Connect to scanner’s host port Connect to scanner’s host port USB ...

  • Honeywell 7820 - page 5

    3 Recall Defaults Scan Recall Defaults to reset all standard product default settings. ³ 999998 Recall Defaults ...

  • Honeywell 7820 - page 6

    4 Interface Selections USB ³ 4164140 ³ 999970 ³ 416400 USB Keyboard Emulation Load Integrated Full Speed USB IBM/OEM Defaults USB Serial Emulation ...

  • Honeywell 7820 - page 7

    5 RS232 Keyb oa rd W e dg e Ke yboard Country Scan a bar code to select one of the following keyboard country templa tes. Refer to your Configuration Guide for add itional keyboard country settings. ³ 415554 RS232 ³ 5155143 Keyboard Wedge Emulation ³ 416260 United States ...

  • Honeywell 7820 - page 8

    6 ³ 416210 ³ 416200 United Kingdom Belgium ³ 416230 Germany/Austria ³ 416220 France ...

  • Honeywell 7820 - page 9

    7 AL T Mode Use ALT Mode when bar codes or formatting rules include Extended ASCII data that might not have a direct keyboard equivalent. If your bar code contains special characters from the extended ASCII chart, scan the Enable 3-digit ALT Mode or Enable 4-digit ALT Mode codes below. The key sequence based on the ASCII value would be sent to the ...

  • Honeywell 7820 - page 10

    8 Note: Scan ALT mode after scanning the appropriate Keyboard Country code. ³ 116217 Enable 3-digit ALT Mode ³ 116716 ³ 116706 Enable 4-digit ALT Mode Disable 3-digit ALT Mode Disable 4-digit ALT Mode ³ 116207 ³ 116716 ...

  • Honeywell 7820 - page 11

    9 RS232 Communication Commands ³ 115816 RTS/CTS Handshaking On ³ 115914 XON/XOFF On ³ 115913 ACK/NAK On ³ 116013 8 Data Bits ...

  • Honeywell 7820 - page 12

    10 P ower Sa ve Modes Scan the following bar codes to have the scanner to enter/exit from various power save modes. ³ 116014 1 Stop Bit ³ 316045 No Parity ³ 319410 Blink ...

  • Honeywell 7820 - page 13

    11 ³ 319420 ³ 319430 ³ 118617 Laser Off Power Save Laser and Motor Off Power Save Power Save Mode Always ³ 818600 Power Save Mode Never ...

  • Honeywell 7820 - page 14

    12 Host Scanner Commands Scan the Enable D/E Disable bar code below to disable scanning after the scanner receives an ASCII “D” from the host. Scanning is enabled when the scanner receives and ASCII “E”. ³ 118015 ³ 118005 Enable D/E Disable Disable D/E Disable ...

  • Honeywell 7820 - page 15

    13 Scan the Activate DC2 Character bar code below initiate scanning with the receipt of a DC2 character (^R, 124). Scanning the Transmit Serial Number code transmits the scanner’s serial number. ³ 118100 Do Not Activate DC2 Character ³ 118110 Activate DC2 Character ³ 999969 Transmit Serial Number ...

  • Honeywell 7820 - page 16

    14 LED Options Scan the Laser LED Off/Sc an LED Off bar code to turn off the laser/scan LED while scanning bar codes. The LEDs continue to illuminate for all other functions. ³ 243130 ³ 243132 Laser LED Off Scan LED Off ...

  • Honeywell 7820 - page 17

    15 Prefix Scan one of the following bar codes to program your scanner to add or remove a start of text character, or AIM, NCR, or Nixdorf identification characters before each bar code. ³ 116615 ³ 116605 STX Prefix On STX Prefix Off ³ 107915 AIM ID Prefix On ...

  • Honeywell 7820 - page 18

    16 ³ 107905 AIM ID Prefix Off ³ 107901 ³ 107911 NCR Prefix On NCR Prefix Off ³ 107917 Nixdorf Prefix On ...

  • Honeywell 7820 - page 19

    17 Suffix Scan one of the following bar codes to program your scanner to add or remove a carriage return, line feed, tab, or end of text after each bar code. ³ 107907 Nixdorf Prefix Off ³ 116613 ³ 116603 CR Suffix On CR Suffix Off ...

  • Honeywell 7820 - page 20

    18 ³ 116612 LF Suffix On ³ 116602 LF Suffix Off ³ 116610 Tab Suffix On ³ 116600 Tab Suffix Off ...

  • Honeywell 7820 - page 21

    19 User Configurable Prefix/Suffix One or two prefix or suff ix characters can be added and assigned for data transm ission. Use one of the codes below with a 3 code byte sequence that represents the desired character ( see ASCII Conversion Chart , end of document) for your prefix or suffix. (To add additiona l prefix/suffix characters, refer to yo ...

  • Honeywell 7820 - page 22

    20 Example: To add an asterisk (*) as a prefix, scan the bar codes: 1. Enter/Exit Programming 2. Configurable Prefix #1 3. Code Byte 0 4. Code Byte 4 5. Code Byte 2 6. Enter/Exit Programming ³ 903500 Configurable Prefix #1 ³ 999999 Enter/Exit Programming ...

  • Honeywell 7820 - page 23

    21 Supplements Scan one of the bar codes below to program your scanner for 2 or 5 digit bar code supplements. ³ 903600 Configurable Prefix #2 ³ 904500 Configurable Suffix #1 ³ 904600 Configurable Suffix #2 ...

  • Honeywell 7820 - page 24

    22 ³ 101217 ³ 101207 2 Digit Supplements Off 2 Digit Supplements On ³ 101216 5 Digit Supplements On ³ 101206 5 Digit Supplements Off ...

  • Honeywell 7820 - page 25

    23 977 (2 Digit) Supplement Required: Tu rn o n t hi s feature when a 2 digit s upplement is required for EAN-13 codes that begin with 977. ³ 101314 977 Supplements On ³ 101304 977 Supplements Off ...

  • Honeywell 7820 - page 26

    24 UPC/EAN Formatting Scan Convert UPC-A to EAN-13 and a leading zero is transmitted befor e a UPC-A bar code to convert it to EAN-13. ³ 107514 Convert UPC-A to EAN-13 ³ 107504 Don’t Convert UPC-A to EAN-13 ...

  • Honeywell 7820 - page 27

    25 Scan Transmit Lead Zero on UPC-E to transmit a zero before each UPC-E bar code. ³ 107513 Transmit Lead Zero on UPC-E ³ 107503 Don’t Transmit Lead Zero on UPC-E ...

  • Honeywell 7820 - page 28

    26 Scan Transmit UPC-A Number System to transmit the UPC-A leading digit with the bar code data. To transmit just th e data, without the leading digit, scan Don’t Transmit UPC-A Number System . ³ 107511 ³ 107501 Don’t Transmit UPC-A Number System Transmit UPC-A Number System ...

  • Honeywell 7820 - page 29

    27 Expand UPC-E to 12 Digits e xpands the UPC-E code to the 12 digit, UPC-A f or mat. ³ 107515 Expand UPC-E to 12 Digits ³ 107505 Don’t Expand UPC-E to 12 Digits ...

  • Honeywell 7820 - page 30

    28 When Code 39 Full ASCII On is scanned, cer tain character pairs within the bar code symbol will be inter preted as a single character . For e xample: $V will be decoded as the AS CII character SYN, and / C will be decoded as the ASCII character #. Check Digits The following selections allow you to specify whether the check digit should be transm ...

  • Honeywell 7820 - page 31

    29 ³ 107517 ³ 107507 Don’t Transmit UPC-A Check Digits *Transmit UPC-A Check Digits ³ 107516 ³ 107506 *Don’t Transmit UPC-E Check Digits Transmit UPC-E Check Digits ...

  • Honeywell 7820 - page 32

    30 GS1 Symbology Due to the large spaces commonly found in GS1 DataBar symbologies, it is recommended that you enable GS1 Double Border Required . Scan the other codes below to enable/disable GS1 Databar 14 and GS1 Limited. ³ 100011 ³ 100413 GS1 Double Border Required Enable GS1 Databar 14 ³ 100403 Disable GS1 Databar 14 ...

  • Honeywell 7820 - page 33

    31 Host Configurations Scan one of the following codes, then scan the Recall Defaults code, to program the scanner for one of the following configurations. ³ 100404 Disable GS1 Limited ³ 100414 Enable GS1 Limited ...

  • Honeywell 7820 - page 34

    32 ³ 84661280 ³ 84660030 ³ 84660140 Verifone® Ruby Terminal Defaults Gilbarco® Terminal Defaults Wincor Nixdorf Terminal Defaults ³ 999998 Recall Defaults ...

  • Honeywell 7820 - page 35

    33 Miscellaneous Minimum Symbol Length specifies the minimum number of characters al lowable for non-UPC/EAN bar codes. Scan the Enter/Exit Programming bar code to begin. Scan Minimum Symbol Length , then scan the minimum number of characters allowed using code byte bar codes, below. To save, scan the Enter/Exit Programming bar code again. ³ 90180 ...

  • Honeywell 7820 - page 36

    34 Code Bytes ³0 ³1 ³3 ³2 ...

  • Honeywell 7820 - page 37

    35 ³6 ³7 ³5 ³4 ...

  • Honeywell 7820 - page 38

    36 ³9 ³8 ...

  • Honeywell 7820 - page 39

    37 ASCII Con version Chart Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char 0 00 NUL 26 1A SUB 52 34 4 78 4E N 104 68 h 1 01 SOH 27 1B ESC 53 35 5 79 4F O 105 69 i 2 02 STX 28 1C FS 54 36 6 80 50 P 106 6A j 3 03 ETX 29 1D GS 55 37 7 81 51 Q 107 6B k 4 04 EOT 30 1E RS 56 38 8 82 52 R 108 6C l 5 05 ENQ 31 1F US 57 39 9 83 53 S 109 6D ...

  • Honeywell 7820 - page 40

    38 Pa t e n t s For patent information, please refer to www.honeywellaidc.com/patents . T echnical Assistance Contact information for technica l support, product service, and repair can be found at www.honeywellaidc.com . Limited W arranty Refer to www.honeywellaidc.com/warranty_information for your product’s warranty information. User Documentat ...

  • Honeywell 7820 - page 41

    39 This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII. © 2012 Honeywell International Inc. All rights reserved. Web Address: www.honeywellaidc.com ...

  • Honeywell 7820 - page 42

    40 ...

  • Honeywell 7820 - page 43

    ...

  • Honeywell 7820 - page 44

    Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com Omni-QS Rev A 05/12 ...

Fabbricante Honeywell Categoria Barcode Reader

I documenti che otteniamo dal fabbricante del dispositivoHoneywell 7820 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Honeywell
- manuali per l’uso 7820
- schede prodotto Honeywell
- opuscoli
- o etichette energetiche Honeywell 7820
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Honeywell 7820.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Honeywell 7820, manuali di manutenzione, brevi manuali o manuali utente Honeywell 7820. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Honeywell 7820.

Manuali per l’uso simili

Manuale completo del dispositivo Honeywell 7820, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Honeywell 7820 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Honeywell 7820.

Il manuale per l’uso completo Honeywell, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Honeywell 7820 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Honeywell 7820, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Honeywell 7820 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Honeywell 7820 - che ci dovrebbe aiutare nei primi passi durante l'uso Honeywell 7820
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Honeywell 7820
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Honeywell 7820 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Honeywell 7820?

Utilizza il modulo sottostante

Se non hai risolto il problema con Honeywell 7820 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Honeywell 7820 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)