  • Cobalt Networks PS-8300 - page 1

    Cob alt Digital Inc. 8310(-C) openGear TM Tw o Rack Unit Frame and Pow er Supply (PS-8300) User Manual 8310-UM Version: 1.0.1 ...

  • Cobalt Networks PS-8300 - page 2

    Page 2 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) 8310 • • • • openGear TM Tw o Rack Unit Frame and Powe r Supply (PS-8300) User Manual • Cobalt Digital Inc. Part Number: 8310-UM • Documen t Versio n: 1.0.1 • Printed in the United States. • Last Au thor: KGM • Print ing Dat e: 04/24/ 08 4:41 PM The information contain ed ...

  • Cobalt Networks PS-8300 - page 3

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 3 of 40 Important Regulatory and Safety Notices Before usin g this produ ct and any ass ociated equipm ent, refer to the “Im portant Safety Instru ctions” listed bel o w so as to av oid personal injury and to prevent produ ct damage. Products m ay requ ire specific equipm ent, and /or installat ...

  • Cobalt Networks PS-8300 - page 4

    Page 4 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Important Safety Instructions Read these in structions . Keep these ins tructions. Heed all w arnings . Follow all instructions . Warn ing The safe operation of this product requires that a protectiv e earth connection be provided. A grounding conductor in the equi pment' s supply cord ...

  • Cobalt Networks PS-8300 - page 5

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 5 of 40 Product Pow e r Cord Requirements Warn ing North American Line Voltages 100 - 120 Volts This product is supplied w ith certi fied 10A/125V S VT ty pe supply cords. Conductors are color coded w hite (neutral), black (line) and green or green /yellow (groun d). Operation of th is equipm ent a ...

  • Cobalt Networks PS-8300 - page 6

    Page 6 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Maintenance/User Serv iceable Parts Routine m aintenance to this Cobalt Digital Inc. product is not required. This product contains no user serviceable parts. If the frame does n ot appear to be working properly, pleas e contact Technical Support u sing the n umbers li sted un der the “Co ...

  • Cobalt Networks PS-8300 - page 7

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 7 of 40 Contents Introduction 9 In This Ch apter................................................................................................................ ...........9 A Word of Thanks .......................................................................................................9 Ove ...

  • Cobalt Networks PS-8300 - page 8

    Page 8 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Install ing the Rear Su pport Bars and Brackets .......................................................... 35 Service Information 36 In This Ch apter ................................................................................................................ ........ 36 Troubleshooting ...

  • Cobalt Networks PS-8300 - page 9

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 9 of 40 Introduction In This Ch apter This chapter contain s the follow ing sections : • A Wor d of Tha nks • Overview • Features • Documenta tion T erms A Word of Thanks Congra tulations o n choosing the 8310 op enGear TM Two Rack Unit Frame and Power Supply (PS- 8300). The Cobalt Digital ...

  • Cobalt Networks PS-8300 - page 10

    Page 10 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Robust Pow er Supplies The 8310 fram e can accomm odate two front- loaded P S-8300 power s upplies. A ltho ugh a si ngle power supply can f ully power a loaded fram e, the add itio n of a second (optional) power supply g ives the fram e full power redu ndancy. Each pow er supply is fed by ...

  • Cobalt Networks PS-8300 - page 11

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 11 of 40 • Robus t 150 Watt Powe r Supply wi th integ ral cooling f an • Optiona l redun dant pow er supply is hot-s w appable for 24/7 operation • Power sw itch is accessi ble from front of the rack f r ame • Power su pplies are replaceable from the f ront of the fram e withou t requiring ...

  • Cobalt Networks PS-8300 - page 12

    Page 12 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Installation and Setup In This Ch apter This chapter contain s the follow ing sections : • Static Discharge • Unpacking • Installing th e Frame • Pow er Supply PS-8300 and Pow er Cable • Fault Reporting • Im provin g Performa nce • Ventilation and Cooling • Cable Co nnectio ...

  • Cobalt Networks PS-8300 - page 13

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 13 of 40 Installing the Frame The 8310 fram e mounts i n the rack frame by means of four rack screw s fastened t hro ugh the fro nt moun ting flan ges. T his sh o u ld normally be sufficient to carry th e lo ad, inclu ding the w eight of accompany ing cables. How ever, in certain applications such ...

  • Cobalt Networks PS-8300 - page 14

    Page 14 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Note In case of a pow er supply failure, contact y o ur openGear TM dealer. The PS-8300 is a power factor corrected s upply, capable of workin g wit h all worl d AC s tandards (100-240V). The su pply has an indicator LED on the front, an d an error detection circuit that w ill indicate the ...

  • Cobalt Networks PS-8300 - page 15

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 15 of 40 Notice For reliable perf ormance, it is recommen ded that the fram e door not b e opene d for lo nger than 5 m i nut e s w he n using the Coo l i ng Fan Module option on frames loaded w ith more than 40 Watt. Figure 1. Cooling Fan Modul e Frame St acking Options Cable Connections SMPTE Ala ...

  • Cobalt Networks PS-8300 - page 16

    Page 16 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) 4. Each AC connector includes a Pow erlock, which is design ed to retain the power cable connector. Clip th e P o w erlock over the s houlder of the inserted A C cable end. 5. Warning Warning Hazardous Voltages Note — In som e countries, it m ay be necessary to supply th e correct main s ...

  • Cobalt Networks PS-8300 - page 17

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 17 of 40 Rear I/O Module Installation If y o u are installing an openGear TM card in a 8310- C-BNC or 8310- BNC frame, s kip this s ection. If y ou received a custom rear I/O module f or you r openGear TM card, y ou w ill need to install the I/O modu le in you r 8310 fram e before you can connect c ...

  • Cobalt Networks PS-8300 - page 18

    Page 18 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) openBUS Connector This RJ45 conn ector is used to exch ange inf ormati on data f rom cards inst alled in t he 8310 frame to an external m onitoring/control system . Only cards havin g the openBUS interface will be able to be monitored and controlled this w ay. This is reserved for futu re ...

  • Cobalt Networks PS-8300 - page 19

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 19 of 40 SMPTE 269M Fault Reporting Option In This Ch apter This chapter contain s the follow ing sections : • Overview • Frame C o n nections • Details Overv iew The SMPTE 269M Fault R eporting sy stem, als o known as a SMPTE “alarm ,” provides an indication if one or more fram e cards e ...

  • Cobalt Networks PS-8300 - page 20

    Page 20 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Frame Connections The SMPTE 269M Fault R eporting conn ection on openGear TM 8310 s eries fram es is prov ided by the FAULT BNC connector, f or interfacing w ith a custom er-designed alarm system . SMPTE F ault BNC Figure 8. SMP TE 269M Alarm Reporting Frame Connecti ons Details The fault ...

  • Cobalt Networks PS-8300 - page 21

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 21 of 40 Specifications In This Ch apter This chapter contain s the Technical Specif ications table. Technical Specifications Table 2. Technic al Specific at ions Category Parameter Specificat ion Input 100 - 240VA C, 47-63 Hz, 190 Watt Outpu t 1 +12V, ± 10%, 0.5A - 12.5A Outpu t 2 -7.5V, ± 10%, ...

  • Cobalt Networks PS-8300 - page 22

    Page 22 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Category Parameter Specificat ion Level 1Vp p nominal Signal Analog video syn c (black burst or t ri-lev el), or AES/EBU DARS Impedan ce 75 Ω terminating Retu rn Los s >30dB to 30MHz Max DC on Ref Inpu t ±1V Alarm Indicator ANS I/SMPTE 269M-1999 cont act closu re Connector Female BNC ...

  • Cobalt Networks PS-8300 - page 23

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 23 of 40 Important Notes: The power dis sipation of each product ins talled in this fram e is indicated in the Specification s section of the docum entation provided with each m odule. For long-term reliab ility and increased product life, it is recom men d ed that the total dissipation of all m od ...

  • Cobalt Networks PS-8300 - page 24

    Page 24 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Frame Features In This Ch apter This chapter contain s the follow ing sections : • Cooli ng Features o Installing the Cooling Fan Mo d ule o Cool i ng Fa n Functions and U ser Contro ls o Installing th e Controller Card o Functions of th e Co n troller Card o Controls an d LEDs of the Co ...

  • Cobalt Networks PS-8300 - page 25

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 25 of 40 Cooling Feature s The standard 8310 f rame can be also be ordered as the 8310- C vers ion, w ith the C ooling Fan Modu le installed as orig inal equipmen t from the factory. How ever, for custom ers wis hing to increase the ventilation on their st andard 8310 fram es, the optional CFM- 831 ...

  • Cobalt Networks PS-8300 - page 26

    Page 26 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) 1. Open the C FM-8310 packag e and remove the com ponents. Verify that all necessary compon ents are included. • Fan PCB 8310A-016 • Fan Filter S985-006 • 8 nu ts 650- 007 • 8 w ashers 960-025 • MFC- 8310(-N) Frame C ontroller C ard 2. Turn fram e power of f. 3. Open the f rame d ...

  • Cobalt Networks PS-8300 - page 27

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 27 of 40 Next y ou will inst all either an MFC-8310 or an MFC- 8310-N controller card. Refer to th e appropriate section for installation instru ctions for y o ur sp ecific controller card. Installing the Controller Card Use th e follow ing procedu re to inst all the MFC- 8310 controller card com p ...

  • Cobalt Networks PS-8300 - page 28

    Page 28 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) seconds af ter the fan door is closed, t hen adjust to th e appropriate lev el based on pow er consumpti on. • Monitors the f rame door an d PS-8300(s) to ensu re that fans in all u nits are operatin g correctly. • Monitors the f an door and n otifies th e user if it is left open too l ...

  • Cobalt Networks PS-8300 - page 29

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 29 of 40 LED displays an d descriptions are pro vided in the following table: Table 3. MFC-8310 Cont roller Card LED Descript ions LED Color Displ ay and Description Alar m (MFC- 8310) Re d When lit, an alarm condition is occurring in th e frame. Status OK (MFC- 8310) Green When lit, the MFC -8310 ...

  • Cobalt Networks PS-8300 - page 30

    Page 30 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Remote Control Netw orking Fea tures This secti on inclu des instruct ions f or installing the MFC-8310- N controller card for th e CFM-8310 modu le. Installi ng the Networ k Controller Car d Perform the phy sical instal lation of the MFC-8310- N controller card for t he CF M-8310 us ing t ...

  • Cobalt Networks PS-8300 - page 31

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 31 of 40 • Monitors f r ame pow er usage an d sets the fan s p eed accordingly (h igher power con sumption req uires higher fan speed for ad e quate c o oling). The fans a l w a ys run a t maximum sp eed for 5 seconds af ter the fan door is closed, t hen adjust to th e appropriate lev el based on ...

  • Cobalt Networks PS-8300 - page 32

    Page 32 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) DIP Switches on the M FC-8310-N The follow ing DIP Sw itches are located on the MFC -8310-N controlle r card. DIP_1 Switch DIP_1 switch disables the audio alarm signal as follow s: • ON — This setting disables the au dio alarm. • OFF — This setting en ables the audio alarm. DIP_2 t ...

  • Cobalt Networks PS-8300 - page 33

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 33 of 40 Table 4. MFC-8310-N Cont roller Card LED Descript ions LED Color Location Di splay and Descri pt ion Alar m (MFC- 8310-N) Red DS1 When lit, an alarm condition is occurrin g in the fram e. Status OK (MFC- 8310-N) Green DS2 When lit, the fan control process is operating correctly. Comm . A c ...

  • Cobalt Networks PS-8300 - page 34

    Page 34 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Enabling SNMP You m ust obtain a l icense k ey from Cobalt Digit al Inc. to en able SNMP support. Use the follow ing procedure to obtain your licen se key: 1. Reques t a license key from you r distributor or at sales@cobaltdigital.com , quoti ng the 8-ch aracter hardware-ID prov ided on th ...

  • Cobalt Networks PS-8300 - page 35

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 35 of 40 Rear Support Bars and Brackets Under normal con ditions, moun ting the fram e to the front of the rack with four rack screw s should be suff icient to carry the load, in cluding the w eight of accom p anying cables . T he option al FSB-8310 Rear Support Bars an d Brackets are specifical ly ...

  • Cobalt Networks PS-8300 - page 36

    Page 36 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Service Information In This Ch apter This chapter contain s the follow ing sections : • Troubleshoot ing Check list • Frame Cont roller Alarm Mute/Bo otload Button • Warranty an d Rep air P olicy Troubleshooti ng Checkl ist Routine m aintenance to this openGear TM product i s not req ...

  • Cobalt Networks PS-8300 - page 37

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 37 of 40 Use the follow ing procedure to reload th e softw are: 1. Eject the card. 2. Press and hold the Alarm Mute/Bo otload button, w hile re-ins erting the card into the frame. 3. Release the bu tton. The STAT US OK LED will flash GREEN w hile the card is w aiting for a new software load. If a n ...

  • Cobalt Networks PS-8300 - page 38

    Page 38 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Ordering Information In This Ch apter Your 8310 op enG ea r TM Two Rack Unit F rame and Pow er Supply (PS-8300) is a part of the openGear TM fam ily of products. We of fer a full line of openGear TM terminal equipm ent including distribution, conver sion, monito ring, synchroniz e rs, enco ...

  • Cobalt Networks PS-8300 - page 39

    8310 Us er Ma nu al • • • • (V 1.0.1) Page 39 of 40 Notes: ...

  • Cobalt Networks PS-8300 - page 40

    Page 40 of 40 8310 Us er Ma nu al • • • • (V 1.0.1) Contact Us Contact Cobalt Digita l Inc. General Business Office and Technical Support 217.344.1243 PHONE Fax 217.344.1245 General Information Info@cobaltdigital.com E-MA I L Sales Information Sales@cobaltdigital.com Cobalt Digi tal Inc. 2406 East Un iversi ty Av enue Urbana, IL 61802 USA P ...

Fabbricante Cobalt Networks Categoria Power Supply

I documenti che otteniamo dal fabbricante del dispositivoCobalt Networks PS-8300 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Cobalt Networks
- manuali per l’uso PS-8300
- schede prodotto Cobalt Networks
- opuscoli
- o etichette energetiche Cobalt Networks PS-8300
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Cobalt Networks PS-8300.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Cobalt Networks PS-8300, manuali di manutenzione, brevi manuali o manuali utente Cobalt Networks PS-8300. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Cobalt Networks PS-8300.

Manuali per l’uso simili

Manuale completo del dispositivo Cobalt Networks PS-8300, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Cobalt Networks PS-8300 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Cobalt Networks PS-8300.

Il manuale per l’uso completo Cobalt Networks, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Cobalt Networks PS-8300 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Cobalt Networks PS-8300, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Cobalt Networks PS-8300 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Cobalt Networks PS-8300 - che ci dovrebbe aiutare nei primi passi durante l'uso Cobalt Networks PS-8300
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Cobalt Networks PS-8300
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Cobalt Networks PS-8300 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Cobalt Networks PS-8300?

Utilizza il modulo sottostante

Se non hai risolto il problema con Cobalt Networks PS-8300 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Cobalt Networks PS-8300 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)