Manuale per l’uso National Instruments NI USB-6525

16 pagine 0.66 mb
Scarica

Vai alla pagina of 16

Summary
  • National Instruments NI USB-6525 - page 1

    USER GUIDE AND SPECIFICATIONS NI USB-6525 This user guide describes how to use the National Instruments USB-6525 data acquisi tion (D A Q) de vice. Introduction The NI USB-6525 is a full-speed USB 2.0 device that provides eight ±60 VDC chan nel-to-channel isolated digital inputs (DI ), eight 60 VDC/30 Vrms channel-to-channel isolated solid-state r ...

  • National Instruments NI USB-6525 - page 2

    USB-6525 User Guide an d Specifications 2 ni.com Figure 2. USB-6525 Back View Installing Software Software suppo rt for the USB-6525 for Wind ows 2000/XP is provided by NI-DAQmx. The NI-D A Q mx CD contains example programs th at you can use to get started programming with the USB-65 25. Refer to the NI-D AQmx for USB Devices Getting Started Guide ...

  • National Instruments NI USB-6525 - page 3

    © National Instruments Co rporation 3 USB-6525 User Guide and Specifications Refer to the Safety G uidelines section of this document for im portant safety information. Setting Up Hardware Complete the f ollowing st eps to set up the hardwa re: 1. Install combicon scr e w terminal blocks by inserting them into th e combicon jacks. Note The USB-652 ...

  • National Instruments NI USB-6525 - page 4

    USB-6525 User Guide an d Specifications 4 ni.com I/O Connector The USB-6525 device ships with two d etachable terminal blocks for digital signals. Each indivi dual terminal accepts a wire gauge between 16 AWG–28 AWG. Table 1. Digital T erminal Assignments Module T erminal Signal Module T erminal Signal 1 P0.0A 17 P1.0+ 2 P0.0B 18 P1.0– 3 P0.1A ...

  • National Instruments NI USB-6525 - page 5

    © National Instruments Co rporation 5 USB-6525 User Guide and Specifications Signal Descriptions Table 2 describes the signals available on the I/O connectors. Digital I/O USB-6525 has eight channel-to-channel op tically isolated inputs, P1.<0..7>, and eight chann el-to-channel optically isolated solid-state relay outputs, P0.<0..7>. P ...

  • National Instruments NI USB-6525 - page 6

    USB-6525 User Guide an d Specifications 6 ni.com Applying a DC voltage of at least 3.2 V across two input terminals registers logic high. Applying no voltage or a voltage dif ference of 1 V or less registers logic lo w . DC voltages between 1 V and 3.2 V may not register a consistent or usable value. Signal Connection Example Figure 5 shows signal ...

  • National Instruments NI USB-6525 - page 7

    © National Instruments Co rporation 7 USB-6525 User Guide and Specifications Solid-State Relay (SSR) Outputs You can connect loads to the USB-6525. Connect the load to one of the leads of the power source. Connect either the P0. x A or the P0. x B terminal to the load and the other terminal to the other lead of the AC or DC power source. Figure 6 ...

  • National Instruments NI USB-6525 - page 8

    USB-6525 User Guide an d Specifications 8 ni.com Figures 7 and 8 show examples of us ing an external flyback diode to protect DC inductiv e loads and an MO V to protect A C inducti ve loads, respecti vely . Figure 7. Contact Protection for DC Inductive Load s Figure 8. Co ntact Protection for AC Inductive Loads Inductive Load USB-6525 Flyback Diode ...

  • National Instruments NI USB-6525 - page 9

    © National Instruments Co rporation 9 USB-6525 User Guide and Specifications Using the USB-6525 as a TTL Output Device Figure 9 shows a sign al connection example for a TTL-level application with an external supply voltage of +5 V. Figure 9. TTL Device Signal C onnection Example When the SSR is open, a small am ount of current flo ws through R L a ...

  • National Instruments NI USB-6525 - page 10

    USB-6525 User Guide an d Specifications 10 ni.com Input current ........... .............. .............. ....3.0 mA/channel max Solid-State Relay Outputs Number of output channels ................. ....8, ch-ch isolated Relay type ..................... .............. ............Normally open solid-state relay (SSR) Switching voltage ............. ...

  • National Instruments NI USB-6525 - page 11

    © National Instruments Corporation 11 USB- 6525 User Guide an d Specifications Power Requirements USB Input voltage ............ ........... ............ 4.5 to 5.25 VDC in configured state Active current ....... .............. ........... . 150 mA max Suspend current...................... ......... 350 μ A ty p Physical Characteristics Dimension ...

  • National Instruments NI USB-6525 - page 12

    USB-6525 User Guide an d Specifications 12 ni.com Isolation Channel-to-channel ............. .............. ......60 VDC continuous Channel-to-earth ground ....... ...... ............60 VDC continuous Withstand . .......... .............. ........... ............60 VDC continuous Caution Do not use this module for connection to signals or for measu ...

  • National Instruments NI USB-6525 - page 13

    © National Instruments Corporation 13 USB- 6525 User Guide an d Specifications CE Compliance This product meets the essential re quirements of applicable European Directives, as amended for CE markin g, as follows: • 73/23/EEC; Lo w-V oltage Directi ve (safety) • 89/336/EEC; Electromag netic Compatibility Directive (EMC) Note Refer to the Decl ...

  • National Instruments NI USB-6525 - page 14

    USB-6525 User Guide an d Specifications 14 ni.com Operate the device only at or belo w Pollution Degree 2. Pollution is foreign matter in a solid, liquid, or gaseous state that can reduce dielectric strength or surface resisti vity . The following is a description of pollution de grees: • Pollution Degree 1 means no pollution or only dry , noncon ...

  • National Instruments NI USB-6525 - page 15

    © National Instruments Corporation 15 USB- 6525 User Guide an d Specifications • Measurement Category III is for measurements performed in the building installation at the distribution le vel. This cate gory refers to measurements on hard-wir ed equipment such as equipment in f ixed installations, distribution boards, and circuit breakers. Other ...

  • National Instruments NI USB-6525 - page 16

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more information abou t National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or t rade names of their respective companie s . For patents covering Nati ...

Fabbricante National Instruments Categoria Marine RADAR

I documenti che otteniamo dal fabbricante del dispositivoNational Instruments NI USB-6525 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici National Instruments
- manuali per l’uso NI USB-6525
- schede prodotto National Instruments
- opuscoli
- o etichette energetiche National Instruments NI USB-6525
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso National Instruments NI USB-6525.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione National Instruments NI USB-6525, manuali di manutenzione, brevi manuali o manuali utente National Instruments NI USB-6525. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto National Instruments NI USB-6525.

Manuale completo del dispositivo National Instruments NI USB-6525, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare National Instruments NI USB-6525 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti National Instruments NI USB-6525.

Il manuale per l’uso completo National Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale National Instruments NI USB-6525 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice National Instruments NI USB-6525, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per National Instruments NI USB-6525 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo National Instruments NI USB-6525 - che ci dovrebbe aiutare nei primi passi durante l'uso National Instruments NI USB-6525
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del National Instruments NI USB-6525
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio National Instruments NI USB-6525 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su National Instruments NI USB-6525?

Utilizza il modulo sottostante

Se non hai risolto il problema con National Instruments NI USB-6525 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con National Instruments NI USB-6525 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)