    271015-UUM-A-0407 USER’S INFORMA TION, MAINTENANCE AND SER VICE MANUAL HIGH EFFICIENC Y TUBULAR HEA T EX CHANGER SERIES MODELS : PV8*DH/FL8V*DH/FC8V*DH/LL8V*DH/LC8V*DH (V ariable Speed Do wnflow/Horizont al/Low NOx) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality Management System The manufacturer recomm ends that the user read all se c- t ...

  • York LC8V*DH - page 2

    271015-UUM-A-0407 2 Unitary Products Group 7. NEVER. . .S tore flammable materials of any kind near your fur- nace. Gasoline, solvents, and ot her volatile liquids should be stored only in approved containers outside your home. These materials vaporiz e easily and are extremely dangerous. 8. NEVER. . .S tore cleaning materials near your fu rnace. M ...

  • York LC8V*DH - page 3

    271015-UUM-A-0407 Unitary Products Group 3 HOW Y OUR GAS FURNA CE WORKS Y our furnace is a very easy appliance to take for granted. Season after season, it sits there in your home, keeping you warm and comfortable. For this reason, you may neve r have given much thought to the way your furnace operates. In order to get the safest and most ef ficien ...

  • York LC8V*DH - page 4

    271015-UUM-A-0407 4 Unitary Products Group Every time the filters are changed the following items should be visually inspected: • Check vent pipe for blockage or leakage. • Check all components to be sure they are in good condition and that there are no obvious signs of deterioration. • Check for dirt or lint on any surfaces or on components. ...

  • York LC8V*DH - page 5

    271015-UUM-A-0407 Unitary Products Group 5 FURNACE CLEANING SECTION NOTE: The cleaning operations listed below must be performed only by a qualified service agency . Burner Remo val/Cleanin g The main burners should be checked per iodically for dirt accumulation. If cleaning is required, follow this procedure: 1. T urn off the electrical power to t ...

  • York LC8V*DH - page 6

    271015-UUM-A-0407 6 Unitary Products Group 5. 1st and 2nd S tage called simultaneously • The 1st stage call is processed as described in paragraph 1 above. • Once Flame Rectification is established, 2nd S tage is entered immediately as described in paragraph 2 above. 6. 1st and 2nd S tage satisfied simultaneously • Both stages of the Gas V al ...

  • York LC8V*DH - page 7

    271015-UUM-A-0407 Unitary Products Group 7 Continuous Blow er Operation The blower will run continuously whenever the wall thermostat fan switch is in the "ON" position. Th e furnace blower will run at the speed selected on the "F AN SPEED" jumpers on the main control board (HI COOL, LO COOL, HI HEA T or LO HE A T). When the jum ...

  • York LC8V*DH - page 8

    271015-UUM-A-0407 8 Unitary Products Group 4 RED FLASHES: This indicates that a prim ary or auxiliary limit switch has opened its normally closed contact s. With this fault code the control will operate the supply air blower and inducer . This condition may be caused by: dirty filter , improperly sized duct sy stem, incorrect blower speed setting, ...

  • York LC8V*DH - page 9

    271015-UUM-A-0407 Unitary Products Group 9 FIGURE 7: Furnace Control Event Schedule W2 SIGNAL ON CLOSED OPEN OPEN CLOSED ABSENT PRESENT HIGH INDUCER HIGH ST AGE PRESSURE SWITCH AND 2ND ST AGE MAIN V AL VE CIRCULA TOR HIGH HEA T SPEED 2ND ST AGE CALL HIGH HEA T AFTER LOW HEA T IS EST ABLISHED HIGH HEA T OFF DELA Y 30 SEC. HIGH LIMIT W1 SIGNAL LOW IN ...

  • York LC8V*DH - page 10

    271015-UUM-A-0407 10 Unitary Products Group SECTION III: REPLACEMENT P ARTS LIST 1 27 6,21 11 2 5 45 46 31 17 22 10 9 8 42 24 38 4 7 12,36 23 20 30 39 16 48 49,50 14 29 51 26 11 13 12 20 36 25 37 7 ...

  • York LC8V*DH - page 11

    271015-UUM-A-0407 Unitary Products Group 11 ITEM DESCRIPTION MOTOR 1 MOTOR/MODULE, ECM (Complete, Programmed) 1A ECM MOTOR MODULE (Programmed, less motor) 1B MOTOR, BLOWER (Less ECM Module) 2 MOTOR, VENT OR ASS’Y ELECTRICAL 3 4 CONTROL, HIGH LIMIT [LS1] 5 CONTROL, FURNACE [FC ] 6 IGNITOR 7 SENSOR, FLAME 8 SWITCH, AIR PRESSURE [1LP] 9 SWITCH, DOOR ...

  • York LC8V*DH - page 12

    271015-UUM-A-0407 12 Unitary Products Group TA B L E 2 : Field Installed Accessories - Non Electrical MODEL NO. DESCRIPTION USED WITH 1NP0347 PROP ANE (LP) CONVERSION KIT ALL MODELS 1PS0313 HIGH AL TITUDE PRESSURE SWITCH KIT* (Does Not Include Orifices) 57, 80, 100 MBH 1PS0314 120 MBH 1CB0314 COMBUSTIBLE FLOOR BASE FOR DOW NFLOW UNITS 14-1/2” (? ...

  • York LC8V*DH - page 13

    271015-UUM-A-0407 Unitary Products Group 13 SECTION IV: WIRING DIAGRAM FIGURE 8: Wiring Diagram ...

  • York LC8V*DH - page 14

    271015-UUM-A-0407 14 Unitary Products Group NOTES ...

  • York LC8V*DH - page 15

    271015-UUM-A-0407 Unitary Products Group 15 NOTES ...

  • York LC8V*DH - page 16

    Subject to change without notice. Printed in U.S.A. 271015-UUM-A-0407 Copyright © by York International Corp. 2007. A ll rights reserved. Supersedes: 167354-UUM-B-0806 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 Limited Warranty UPG warrant s this produc t to be free from def ects in facto ry workmanshi p and material unde r normal us ...

Fabbricante York Categoria Thermostat

I documenti che otteniamo dal fabbricante del dispositivoYork LC8V*DH possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici York
- manuali per l’uso LC8V*DH
- schede prodotto York
- opuscoli
- o etichette energetiche York LC8V*DH
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso York LC8V*DH.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione York LC8V*DH, manuali di manutenzione, brevi manuali o manuali utente York LC8V*DH. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto York LC8V*DH.

Manuali per l’uso simili

Manuale completo del dispositivo York LC8V*DH, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare York LC8V*DH dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti York LC8V*DH.

Il manuale per l’uso completo York, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale York LC8V*DH - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice York LC8V*DH, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per York LC8V*DH che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo York LC8V*DH - che ci dovrebbe aiutare nei primi passi durante l'uso York LC8V*DH
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del York LC8V*DH
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio York LC8V*DH in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su York LC8V*DH?

Utilizza il modulo sottostante

Se non hai risolto il problema con York LC8V*DH con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con York LC8V*DH è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)