    http://www .omega.com e-mail: info@omega.com omega.com ® ® U ser ’ s Guide CN3440 SERIES Universal T emperature & Pr ocess Contr ollers Installation Guide ...

  • Omega CN3440 - page 2

    WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 37 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal three (3) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers rec ...

  • Omega CN3440 - page 3

    1 CONTENTS 1 INTRODUCTION .................................. 2 2 PREPARATION .................................... 3 2.1 Checking the Code Number ......... 3 3 MECHANICAL INSTALLATION .......... 4 3.1 Siting .......................................... 4 3.2 Mounting ...................................... 5 4 ELECTRICAL INSTALLATION ............ 6 4.1 ...

  • Omega CN3440 - page 4

    2 The instrument documentation is shown in Fig. 1.1. The Standard Manuals , including the specification sheet, are supplied with all instruments. The Modbus Supplement is supplied with instruments configured for Modbus Serial Communication. This manual includes an Installation Record which should be completed as a log of the electrical installation ...

  • Omega CN3440 - page 5

    3 2 PREP ARA TION 2.1 Checking the Code Number – Fig. 2.1 Fig. 2.1 Location of Code Number Label Code Number Label XXXX / X X X X X X X X ...

  • Omega CN3440 - page 6

    4 3 MECHANICAL INST ALLA TION EC Directive 89/336/EEC In order to meet the requirements of the EC Directive 89/336/EEC for EMC regulations, this product must not be used in a non-industrial environment. 3.1 Siting – Figs. 3.1 and 3.2 A – Within Temperature Limits B – Within Humidity Limits Sensor Minimum A – Close to Sensor B – At Eye-lev ...

  • Omega CN3440 - page 7

    5 3 MECHANICAL INSTALLATION… 3.2 Mounting – Figs. 3.3 and 3.4 The instrument is designed for wall-/pipe-mounting – see Fig. 3.4. Overall dimensions are shown in Fig. 3.3. Dimensions in inches (mm) 2.68 (68) 8.43 (214) 9.13 (232) Fixing Centres 6.3 (160) 9.84 (250) 2.72 (69) Fixing Centres Allowance for Cable Bends 7.9 (200) 1.65 (42) 2 3 / 8 ...

  • Omega CN3440 - page 8

    6 4 ELECTRICAL INST ALLA TION Warning. Before making any connections, ensure that the power supply, any high voltage-operated control circuits and high common mode voltages are switched off. Note. • Always route signal leads and power cables separately, preferably in earthed metal conduit. • It is strongly recommended that screened cable is use ...

  • Omega CN3440 - page 9

    7 4 ELECTRICAL INSTALLATION… B – Isolated Output Types Fig. 4.2 Setting the Selector Links A – Input Types PL3 Position Feedback Input PL2 Remote Set Point Input PL1 Process V ariable Input PL2 PL1 1 6 12 7 1 4 8 5 PL1 PL2 1 6 12 7 1 4 8 5 PL1 PL2 1 6 12 7 1 4 8 5 2-wire T ransmitter Input 1 6 12 7 PL1 1 2 Identify Link PL7 Set links for outp ...

  • Omega CN3440 - page 10

    8 …4 ELECTRICAL INSTALLATION 4.4 Cable Glands and Conduit Fixings 4.4.1 Cable Glands (IEC – 20mm) – Fig. 4.3 4.4.2 Conduit Adaptors (N. American – 0.5in) – Fig. 4.4 Warning. • Rigid conduit must NOT be fitted to the controller. • Controller adaptors must incorporate a face seal. • Torque settings for the hubs and outer nuts on the s ...

  • Omega CN3440 - page 11

    9 4 ELECTRICAL INSTALLATION… Fig. 4.5 Cable Glands 4.4.3 Cable Glands (N. American – 0.5in) – Fig. 4.5 Warning. • Controller glands must be fitted with a face seal. • Torque settings (hubs only) – 20ft. lbs minimum, 25ft. lbs. maximum. • Outer nuts – hand tight plus a half turn only. Information. • Suitable Cable Glands: (mandator ...

  • Omega CN3440 - page 12

    10 …4 ELECTRICAL INSTALLATION Fig. 4.6 Terminal Block Identification 4.5 Connections Summary – Fig. 4.6 Information. Input impedances: Low voltage(mV) >10M Ω Voltage >10M Ω Current 10 Ω . 3 4 56 7 8 9 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 10 1 1 12 13 14 15 12 16 17 Power Supply Relay 1 Relay 2 Relay 3 MODBUS (RTU) (if option ...

  • Omega CN3440 - page 13

    11 4 ELECTRICAL INSTALLATION… Table 4.1 Electrical Connections T erminal Number 1 2 3 N/O 4 C 5 N/C 6 N/O 7 C 8 N/C 9 N/O 10 C 11 N/C 12 13 14 15 16 17 18 Tx+ 19 Tx – 20 Common 21 Rx+ 22 Rx – 23 + 24 – 25 + 26 – 27 3rd lead 28 Input 3+ 29 Input 3 – 30 31 32 3rd lead/2-wire TX Input 1+ Input 1 – 3rd lead Input 2+ Input 2 – Retransmis ...

  • Omega CN3440 - page 14

    12 4.6 Input Connections Make connections to each input, as shown in Figs 4.4 to 4.14, first removing any factory-fitted wire links not required. 4.6.1 Thermocouple (THC) Inputs – Fig. 4.7 Note. Automatic Cold Junction Compensation (ACJC) is active when an input is programmed for use with thermocouples. Use the correct compensating cable between ...

  • Omega CN3440 - page 15

    13 & ^ % Remote Set Point & ^ % Remote Set Point Sleeved Link $ £ @ & ^ % Process V ariable Remote Set Point Sleeved Link Red White Fig. 4.8 3-lead Resistance Thermometer Input Connections Fig. 4.9 2-lead Resistance Thermometer Input Connections Fig. 4.10 3-lead Resistance Remote Set Point Input Connections Fig. 4.11 2-lead Resistance ...

  • Omega CN3440 - page 16

    14 4.7 Output Connections Make connections as shown in Figs 4.15 and 4.16. 4.8 Relay Connections – Fig. 4.17 For relay functions refer to the following table. A – Standard Feedback Slidewire Configuration B – Alternative Feedback Slidewire Configuration Note. Link must be connected at the motorized valve drive terminals and not the Controller ...

  • Omega CN3440 - page 17

    15 31 30 32 Logic Input 2 Manual Automatic Local Remote or Dual Fixed Dual Set P oint 2 Fixed Dual Set P oint 1 * Alarm Acknowledge * Leading 'edge-triggered' (minimum duration 200ms) 5V 0V Logic switching Auto/ Manual Selection Local/Remote Set P oint Selection Dual Set P oint Selection Alarm Acknowledgement Common Logic Input 1 Automati ...

  • Omega CN3440 - page 18

    16 4.11 P ower Supply Selection and A C Connections – Fig. 4.22 Fig. 4.22 Power Supply Selection and AC Connections … 4 ELECTRICAL INSTALLATION Information. Fuse Rating - 5A Type T 11 5 Selector not Fitted (24V AC) Code Label Digit 7 3 2 1 C31 x x x x x x x x x 11 5 230 Remove plug to make connection A – Selecting the Supply V oltage B – Po ...

  • Omega CN3440 - page 19

    17 Power Supply 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 L N NO C NC NO C NC NO C NC 3rd + – 3rd + – Tx+ Tx – Common Rx+ Rx – + – Connection/T erminal Number Retransmission Output Relay 1 Output Relay 2 Output Power Supply (Tick Box) 230V AC 1 15V AC 24V AC Output T ype: Output Function: Output T ype: Output Function ...

  • Omega CN3440 - page 20

    18 25 26 27 28 29 30 31 32 + – 3rd + – Connection/T erminal Number Control Output Position Feedback Input Common (Tick Box) Link Positions Analog Output Logic Output Logic Input 1 Logic Input 2 V mA mV (Tick Box) Link Positions R … 4 ELECTRICAL INSTALLATION ...

  • Omega CN3440 - page 21

    19 NOTES ...

  • Omega CN3440 - page 22

    20 … NOTES ...

  • Omega CN3440 - page 23

    Servicing Nor th America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales Service: 1 ...

  • Omega CN3440 - page 24

    M2954/0 7 0 2 TEMPERA TURE Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies W ire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Contr ollers & Process Monitors Infrared Pyr ometers PRESSURE, STRAIN AND FORCE T ransducers & Strain Gauges Load Cells & Pressur e Gauges ...

Fabbricante Omega Categoria Thermostat

I documenti che otteniamo dal fabbricante del dispositivoOmega CN3440 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Omega
- manuali per l’uso CN3440
- schede prodotto Omega
- opuscoli
- o etichette energetiche Omega CN3440
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Omega CN3440.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Omega CN3440, manuali di manutenzione, brevi manuali o manuali utente Omega CN3440. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Omega CN3440.

Manuali per l’uso simili

Manuale completo del dispositivo Omega CN3440, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Omega CN3440 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Omega CN3440.

Il manuale per l’uso completo Omega, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Omega CN3440 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Omega CN3440, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Omega CN3440 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Omega CN3440 - che ci dovrebbe aiutare nei primi passi durante l'uso Omega CN3440
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Omega CN3440
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Omega CN3440 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Omega CN3440?

Utilizza il modulo sottostante

Se non hai risolto il problema con Omega CN3440 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Omega CN3440 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)