    323356B-01 May 2003 © 2002–2003 Nationa l Instruments Corp. A ll rights res erved. FieldPoint™, Nati onal Instruments™, NI™, and ni.com™ are trademarks of N ational Instruments Corpo ration. Product and company names ment ioned herein are trademark s or trade names of their respective c ompanies. For patents covering National Inst rument ...

  • National Instruments FP-PG-522 - page 2

    FP-PG-522 and cFP-PG-522 2 ni.com Installing the FP-PG-522 The FP-PG-522 mounts on a FieldPoint terminal base (FP-TB- x ), which provides operating po wer to the module. Instal ling the FP-PG-522 onto a po wered termin al base does not disrupt the operation of the bank. T o install the FP-PG-522, refer to Figure 1 and co mplete the follow ing steps ...

  • National Instruments FP-PG-522 - page 3

    © National Instruments Corp . 3 FP-PG-522 and cFP-PG-522 T o install the cFP-PG-522, refe r to Figure 2 and complete the follow ing steps: 1. Align the capti ve scre ws on th e cFP-PG-522 with the holes on the backplane. The alignment keys on the cFP-PG-522 pre vent backward insertion. 2. Press firm ly to seat the cFP-PG-522 on th e backplane. 3. ...

  • National Instruments FP-PG-522 - page 4

    FP-PG-522 and cFP-PG-522 4 ni.com Wiring the [c]FP-PG-522 The FP-TB- x terminal base ha s connections for each of the eight output channels and for an exte rnal power supply to po wer the output channels and field de vices. The cFP-CB- x connector block provides th e same connections. Each ch annel has one outpu t terminal (V OUT ), two supply term ...

  • National Instruments FP-PG-522 - page 5

    © National Instruments Corp . 5 FP-PG-522 and cFP-PG-522 T able 1 lists the term inal assign ments for the signals of each channel. T erminal assignments are also listed on the side pane l of the cFP-PG-522 and un der the slide-in card on the front of the FP-PG-522. Pulse Output Circuit The [c]FP-PG-522 output channels are opti cally isolated fr o ...

  • National Instruments FP-PG-522 - page 6

    FP-PG-522 and cFP-PG-522 6 ni.com T able 2 sho ws some common combinations of output current le v els on sev eral channels. In the ON state, the ef fe cti ve resist ance between V OUT and COM is 0.12 Ω , which causes a v oltage drop. F or example, if the output current is 1 A, the voltage drop is 0.12 V : (1 A × 0.12 Ω ) = 0.12 V Configuring t ...

  • National Instruments FP-PG-522 - page 7

    © National Instruments Corp . 7 FP-PG-522 and cFP-PG-522 A channel set to Continuo us mode must be swit ched to Finite mode in order to stop pulse generation. When switched to Fi nite mode from Continuous mode, a channel finishes generating the current pulse and then stops. On Time The On T ime attrib ute for a channel controls the duration of the ...

  • National Instruments FP-PG-522 - page 8

    FP-PG-522 and cFP-PG-522 8 ni.com T o calcula te On Time and Off T ime , di vide the desired On or Of f T ime for the pulse b y the Resoluti on. F or examp le, to generate a pulse that is on for 3.5 s and off for 0.25 s using a 100 µ s Resolution, set the On T ime to 35,000 and the Off Time to 2,500 (100 µ s = 0.0001 s; On T ime = 3.5/0.0001 = 35 ...

  • National Instruments FP-PG-522 - page 9

    © National Instruments Corp . 9 FP-PG-522 and cFP-PG-522 va lues, which reflect the number of pulses each channel has left to generate after the current puls e. When you send the Generate Pulses command to one of these channels, the data immediately changes to reflect the number of pulses that remain. The data value starts at the total number of p ...

  • National Instruments FP-PG-522 - page 10

    FP-PG-522 and cFP-PG-522 10 ni.com When the network module recogni zes the [c]FP-PG-52 2, it sends initial conf iguration informat ion to the [c]FP-PG-522. After the [c]FP-PG-522 recei ves this in itial information , the green READY indicator lights and the [c]FP-PG-5 22 is in normal operating mode. In addition to the green POWER and READY indicato ...

  • National Instruments FP-PG-522 - page 11

    © National Instruments Corp. 1 1 FP-PG-522 and cFP-PG-522 follow ing symbol stamped beside it: . Connect the backplane PE ground terminal to the system safety ground using 14 A WG (1.6 mm) wire with a ring lug. Use the 5/16 in. panhead screw shipped with the backplane to secure the ring lug to the backplane PE ground terminal. • As with any haza ...

  • National Instruments FP-PG-522 - page 12

    FP-PG-522 and cFP-PG-522 12 ni.com Physical Char acteristics Indicators ............ ........... ......... .......... Green POWER and READY indicators, eight green output st ate indicators W eight FP-PG-522 .... ........... ........... ........ 130 g (4.6 oz) cFP-PG-522 .. ............. ............ ..... 100 g (3.5 oz) Power Requirements Power fro ...

  • National Instruments FP-PG-522 - page 13

    © National Instruments Corp. 1 3 FP-PG-522 and cFP-PG-522 Operating shock (IEC 60068-2-27)........... ........... ........ 50 g, 3 ms half sine, 18 shocks at 6 orientations; 30 g, 11 ms half sine, 18 shocks at 6 orientations Safety This product is designed to meet the requirements of the following standards of safety for electric al equipment for ...

  • National Instruments FP-PG-522 - page 14

    FP-PG-522 and cFP-PG-522 14 ni.com Mechanical Dimensions Figure 5 sho ws the mechanical dimen sions of the FP-PG-522 installed on a termin al base. If you are using the cFP-PG-522, refer to your Compact FieldPo int controller user manual for the dimensions and cabling clearance require ments of the Compact FieldPoint system. Figure 5. FP-PG-522 Mec ...

  • National Instruments FP-PG-522 - page 15

    © National Instruments Corp. 1 5 FP-PG-522 and cFP-PG-522 Czech Republic 420 2 2423 5774, Denmark 45 45 76 26 00, Finland 385 0 9 725 725 11, France 33 0 1 48 14 24 24, Germany 49 0 89 741 31 30, Greece 30 2 10 42 96 427, India 91 80 51190000, Israel 972 0 3 6393737, Italy 39 02 413091, Japan 81 3 54 72 2970, K orea 82 02 3451 3400, Malaysia 603 9 ...

Fabbricante National Instruments Categoria Blood Pressure Monitor

I documenti che otteniamo dal fabbricante del dispositivoNational Instruments FP-PG-522 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici National Instruments
- manuali per l’uso FP-PG-522
- schede prodotto National Instruments
- opuscoli
- o etichette energetiche National Instruments FP-PG-522
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso National Instruments FP-PG-522.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione National Instruments FP-PG-522, manuali di manutenzione, brevi manuali o manuali utente National Instruments FP-PG-522. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto National Instruments FP-PG-522.

Manuale completo del dispositivo National Instruments FP-PG-522, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare National Instruments FP-PG-522 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti National Instruments FP-PG-522.

Il manuale per l’uso completo National Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale National Instruments FP-PG-522 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice National Instruments FP-PG-522, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per National Instruments FP-PG-522 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo National Instruments FP-PG-522 - che ci dovrebbe aiutare nei primi passi durante l'uso National Instruments FP-PG-522
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del National Instruments FP-PG-522
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio National Instruments FP-PG-522 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su National Instruments FP-PG-522?

Utilizza il modulo sottostante

Se non hai risolto il problema con National Instruments FP-PG-522 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con National Instruments FP-PG-522 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)