Manuale per l’uso Westinghouse MR 72161

16 pagine 1.45 mb
Scarica

Vai alla pagina of 16

Summary
  • Westinghouse MR 72161 - page 1

    ETL-ES-Solana-WH09 Please write model number here for futur e refer ence: Por fav or , incluya el númer o del modelo aquí para futura r eferencia: MR 72161 T able of C ont ents Índice Safety Information ................................................................................................................................................ ...

  • Westinghouse MR 72161 - page 2

    2 ETL-ES-Solana-WH09 PREP AR A TION / PREP AR A CIÓN Before beginning assembly , installa tion or operation of product, make sure all parts are present. Compar e parts with the Parts Reference List. Estima ted Assembly T ime: 35 minutes (standard installation) T ools Required for Assembly: Phillips Screwdriver , Step Ladder . (not included) Antes ...

  • Westinghouse MR 72161 - page 3

    3 ETL-ES-Solana-WH09 DOWNROD INST ALLA TION instalación con v a rilla vertical F or nor mal ceilings Par a cielorrasos normales May require a longer downr od (sold separately) Podría requerir una v arilla ver tical más larga (se vende por separado) V A UL TED CEILING INST ALLA TION INST AL ACIÓN P ARA CIEL OR A SOS ABOVEDADOS FEA TURES / CAR A ...

  • Westinghouse MR 72161 - page 4

    4 ETL-ES-Solana-WH09 P ARTS /REFERENCE LIST LIST A DE PIEZAS CON LETRAS DE REFERENCIA Part Description Quantity NOTE: The ref erence list below assig ns a letter to each part referenced in the assembly instructions. U se this refer ence as both a descriptive listing, as well as designa tion of the parts’ final location. NO T A: La siguiente list ...

  • Westinghouse MR 72161 - page 5

    5 ETL-ES-Solana-WH09 A K F H C E IJ M R G N V T S O U W X Y Z P Q L HI MED LO W OF F B D Parts missing or damaged? Please visit ww w .westinghouselighting.com/support/ Questions or problems installing your fan? Please c ontact your local electrician. ¿Hay piezas faltantes o dañadas? Por fav or , visite w ww .westinghouselighting.c om/supp ort/ ¿ ...

  • Westinghouse MR 72161 - page 6

    6 ETL-ES-Solana-WH09 Install mounting bracket (F) to outlet box in ceiling using the scr ews and washers provided with the outlet bo x. Instale el soporte de montaje (F) a la caja de embutir del cielorraso con la tornillería suministrada con la c aja de embutir. Remove clamp pin (M) and cross pin (N) fr om downrod (I). Quite el pasador tipo prensa ...

  • Westinghouse MR 72161 - page 7

    7 ETL-ES-Solana-WH09 5 NORMAL DOWNROD INST ALLA TION - If installing downrod supplied with fan, proc eed to step 6. EXTENDED DOWNROD INST ALLA TION - If installing with longer downrod than supplied with fan, proceed to step 8. NORMAL -Si instala la varilla vertical incluida con el ventilador , proceda al paso 6. OPCIÓN CON V ARILL A VERTICAL MÁS ...

  • Westinghouse MR 72161 - page 8

    8 ETL-ES-Solana-WH09 9 Re -install pin (O) int o extended downrod, and slide downr od ball (H) up to the top of the downrod. Re-install set screw (Q) to secur e ball to downrod. Note: Some extended downrods have a pr e- drilled set-screw hole. If a pre-dr illed hole is present in the extended downrod, tighten the set scr ew into the pre -drilled ho ...

  • Westinghouse MR 72161 - page 9

    9 ETL-ES-Solana-WH09 L F S S E F H K 12 This remote con trol unit is equipped with 16 code combinations t o prevent possible int erference from or to other remot e units. The frequency switches on your rec eiver (L) and transmitter (K) have been preset at the factor y . Please recheck to make sure the switches on transmitter (K) and receiver (L) ar ...

  • Westinghouse MR 72161 - page 10

    10 ETL-ES-Solana-WH09 15 The inside canopy cov er ring (G) has two keyhole slots that allow it to be mounted onto the scr ew heads on the two protruding screws from the mounting bracket. Slide the canopy c over ring up the downrod, and allo w the two protruding screw heads fr om the mounting bracket to go into the keyhole slots on the canop y cover ...

  • Westinghouse MR 72161 - page 11

    11 ETL-ES-Solana-WH09 16 17 18 Attach blades (C) to the flywheel (B) using the blade bracket screws ( T ) and metal washers ( V ). Fije las paletas (C) a la rueda (B) con los tornillos correspondient es ( T ) y las arandelas de metal (V ). Install E12 base, max 60W bulb (X) (included). Instale las bombilla (X) de base E12 de un máximo de 60 vatio ...

  • Westinghouse MR 72161 - page 12

    12 ETL-ES-Solana-WH09 19 20 21 Mount wall bracket to the wall using screw s provided. Instale el soporte de pared sobre la pared con los tornillos incluidos. Place the transmitter int o the mounted holder . Coloque el transmisor en el soporte montado. Remote Contr ol Operation 1. F an Control– press and release . The remote control operates the f ...

  • Westinghouse MR 72161 - page 13

    13 ETL-ES-Solana-WH09 NOTICE This ‘Energy Policy Act 2005’ compliant fan includes a device that limits the total wattage of its light fixture to 190 w atts. By installing a combination of light bulbs that exc eeds 190 watts or if an electrical surge causes the wattage to exceed 190 wa tts, the light fixture will either dim the lights to 190 w ...

  • Westinghouse MR 72161 - page 14

    14 ETL-ES-Solana-WH09 Operation Maintenanc e T roubleshooting Guide 1. Because of the fan’ s natural movement, some c onnections may become loose. Check the support connections, brackets, and blade attachments twice a year . Make sure they are secure. 2. Clean your fan periodically to help maintain its new appearance o ver the years . Do not use ...

  • Westinghouse MR 72161 - page 15

    15 ETL-ES-Solana-WH09 Operación Mantenimiento Guía para solucionar problemas 1. El movimiento natural del v entilador podría hacer que se aflojen algunas conexiones. Verifique las c onexiones de sopor te, las piezas de fijación y los accesorios de las paletas dos veces al año. Cerciór ese de que estén aseguradas . 2. Limpie el ventilador ...

  • Westinghouse MR 72161 - page 16

    ETL-ES-Solana-WH09 W estinghouse Lighting Corporation, a W estinghouse Electric Corporation licensee is a register ed trademark of W estinghouse Electric Corporation Made in China © 2009 W estinghouse Lighting Corporation W estinghouse Lighting Corporation, titular de la licencia de W estinghouse Electr ic Corporation es una marca registrada de W ...

Fabbricante Westinghouse Categoria Outdoor Ceiling Fan

I documenti che otteniamo dal fabbricante del dispositivoWestinghouse MR 72161 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Westinghouse
- manuali per l’uso MR 72161
- schede prodotto Westinghouse
- opuscoli
- o etichette energetiche Westinghouse MR 72161
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Westinghouse MR 72161.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Westinghouse MR 72161, manuali di manutenzione, brevi manuali o manuali utente Westinghouse MR 72161. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Westinghouse MR 72161.

Manuale completo del dispositivo Westinghouse MR 72161, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Westinghouse MR 72161 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Westinghouse MR 72161.

Il manuale per l’uso completo Westinghouse, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Westinghouse MR 72161 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Westinghouse MR 72161, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Westinghouse MR 72161 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Westinghouse MR 72161 - che ci dovrebbe aiutare nei primi passi durante l'uso Westinghouse MR 72161
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Westinghouse MR 72161
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Westinghouse MR 72161 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Westinghouse MR 72161?

Utilizza il modulo sottostante

Se non hai risolto il problema con Westinghouse MR 72161 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Westinghouse MR 72161 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)