    INSTALLATION GUIDE NI TB-2708 PXI T erminal Block for S Seri es Devices This installation guide des cribes how to install and connect sig nals to the NI TB-2 708 terminal block for use with PXI-6115/ 6120 S Ser ies devi ces. Caution Th e connectors of the TB-2708 are sen sitiv e to electrostatic dischar ge (ESD). Th e user s hould grou nd thems elv ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 2

    NI TB-2708 I nstallation Guide 2 ni.com The nine SMB con nectors on the TB-2708 allow yo u to easily conn ect analog in put and analog ou tput signal s to you r Nation al Inst ruments de v ice. The 14-pin I/O connect or located on the bottom of the TB- 2708 allo ws access to digital signals. Caution Th e TB-2708 i s not des igned for i nput v oltag ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 3

    © Natio nal Instrum ent s Corpora tion 3 NI TB-2708 Inst alla tion Guide Do not substitute parts or modify equipment. Because of the danger of introducing additional hazards, d o not install unauthor ized parts or modify the device. Return the de vice to National Instru ments for service and re pair to ensure that its safety features are not co mp ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 4

    NI TB-2708 I nstallation Guide 4 ni.com T o conn ect the terminal block to the PXI module I/O connector , refer to Figure 2 as you complete the following steps: 1. Install the PXI module into the chass is and tighten the two module scre ws. Y ou must ins tall the PXI de vice before co nnecting the TB-2708. Refer to t he DAQ Getting Started Guide fo ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 5

    © Natio nal Instrum ent s Corpora tion 5 NI TB-2708 Inst alla tion Guide Figu re 4. NI TB -2708 B lock Dia gram For more detailed descriptions of these signals, refer to the S Series User Manual . Addit ion al s ign al co nfigur ati on in for m ation is av ailable in Measurement & Automation Explor er (MAX). T o acces s this information in MAX ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 6

    NI TB-2708 I nstallation Guide 6 ni.com Measuring F loatin g Signals You can use the TB-27 08 to measure floating and ground -referenced analog input signals. To measure floating signal sources, move the switch located under th e rubber-sealed doo r on the enclos ure cover for the AI channel you are using to the ON (floating source) switch position ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 7

    © Natio nal Instrum ent s Corpora tion 7 NI TB-2708 Inst alla tion Guide Cabling Options This section descr ibes the cabling op tions for accessing s ignals on the TB-2708. A 14-pin con nector on the bo ttom of the TB-2708 provide s access to digital I/O signals. Use the MFIT -Pigtail Cable Assem bly (part number 194123- 01) to access digital sig ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 8

    NI TB-2708 I nstallation Guide 8 ni.com T able 4 lists the National Instrum ents cables av ai lable for connecting the TB-2708 to both analog and dig ital user signals. 5 Orange P0.3 6 Blue CTR 0 O UT 7 White/Black GND 8 Red/Black P0.4 9 Green/Black P0.5 10 Orange/Black P0.6 11 Blue/Black P0.7 12 Drain W ire CHASSIS GN D 13 Red/W hite CTR 1 OUT 14 ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 9

    © Natio nal Instrum ent s Corpora tion 9 NI TB-2708 Inst alla tion Guide Specificatio ns This section lists the specificati ons of the TB -2708. Thes e specifications are typical at 25 °C unless otherwise specified. Inpu t/O utput Refer to the documentat ion for your PXI-6115/ 6120 S Ser ies device t o determine the inpu t/output specif ications ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 10

    NI TB-2708 I nstallation Guide 10 ni.com Environment The N I TB- 270 8 i s int ende d fo r ind oor use only . Operating temperature ...................... ......0 to 55 °C Storage temperature .......................... ......–20 to 70 °C Relative humidity . ........... ................. ......10 to 90% noncon densing Pollution Degree .......... ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 11

    © Natio nal Instrum ent s Corporati on 11 NI TB-2708 In stalla tion Gui de National Instrumen ts corporate headqu arters is located at 11500 Nor th Mopac Exp ressw ay , Austin, T exas, 787 59-3504. National Instruments also has of fi ces located ar ound the wo rld to hel p address your supp ort needs. For telephone s upport in the United States, c ...

  • National Instruments PXI Terminal Block NI TB-2708 - page 12

    National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments C orporation. Refer to the Terms of Use section on ni.com/legal for more informa tion about N ational Instruments trademarks. Other product and company names ment ioned herein are trademarks or tr ade names of their respect ive companies. For patents covering Natio ...

Fabbricante National Instruments Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoNational Instruments PXI Terminal Block NI TB-2708 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici National Instruments
- manuali per l’uso PXI Terminal Block NI TB-2708
- schede prodotto National Instruments
- opuscoli
- o etichette energetiche National Instruments PXI Terminal Block NI TB-2708
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso National Instruments PXI Terminal Block NI TB-2708.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione National Instruments PXI Terminal Block NI TB-2708, manuali di manutenzione, brevi manuali o manuali utente National Instruments PXI Terminal Block NI TB-2708. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto National Instruments PXI Terminal Block NI TB-2708.

Manuale completo del dispositivo National Instruments PXI Terminal Block NI TB-2708, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare National Instruments PXI Terminal Block NI TB-2708 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti National Instruments PXI Terminal Block NI TB-2708.

Il manuale per l’uso completo National Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale National Instruments PXI Terminal Block NI TB-2708 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice National Instruments PXI Terminal Block NI TB-2708, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per National Instruments PXI Terminal Block NI TB-2708 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo National Instruments PXI Terminal Block NI TB-2708 - che ci dovrebbe aiutare nei primi passi durante l'uso National Instruments PXI Terminal Block NI TB-2708
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del National Instruments PXI Terminal Block NI TB-2708
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio National Instruments PXI Terminal Block NI TB-2708 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su National Instruments PXI Terminal Block NI TB-2708?

Utilizza il modulo sottostante

Se non hai risolto il problema con National Instruments PXI Terminal Block NI TB-2708 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con National Instruments PXI Terminal Block NI TB-2708 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)