    7" PORT ABLE WET CUTTING TILE SA W Model 40315 SET UP AND OPERA TING INSTRUCTIONS Please Note: Diamond Blade not included, sold separately . Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2008 by Harbor Freight T o ...

  • Chicago Electric 40315 - page 2

    Page 2 SKU 40315 For technical questions, please call 1-800-444-3353. SA VE THIS MANUAL Keep this manual for the safety warn- ings and precautions, assembly , operat- ing, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if produc ...

  • Chicago Electric 40315 - page 3

    Page 3 SKU 40315 For technical questions, please call 1-800-444-3353. plugs with grounded power tools. Unmodied plugs and matching out - lets will reduce risk of electric shock. b. A void body contact with grounded surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is grounded. ...

  • Chicago Electric 40315 - page 4

    Page 4 SKU 40315 For technical questions, please call 1-800-444-3353. do the job better and safer at the rate for which it was designed. b. Do not use the power tool if the switch does not turn it on and off. Any power tool that cannot be con- trolled with the switch is dangerous and must be repaired. c. Disconnect the plug from the power source an ...

  • Chicago Electric 40315 - page 5

    Page 5 SKU 40315 For technical questions, please call 1-800-444-3353. 4. Use tools with the lowest vibration when there is a choice between dif- ferent processes. 5. Include vibration-free periods each day of work. 6. Grip tool as lightly as possible (while still keeping safe control of it). Let the tool do the work. 7. T o reduce vibration, mainta ...

  • Chicago Electric 40315 - page 6

    Page 6 SKU 40315 For technical questions, please call 1-800-444-3353. 14. POWER CORD 120 VOL T , GROUNDED ELECTRICAL OUTLET TILE SA W DRIP LOOP Figure 1 Always arrange a “drip loop” in the Power Cord/Plug (34) connecting the Tile Saw to a 120 volt, ground- ed, electrical outlet. A drip loop is that part of the Power Cord below the level of the ...

  • Chicago Electric 40315 - page 7

    Page 7 SKU 40315 For technical questions, please call 1-800-444-3353. 27. Never attempt to remove material stuck in the moving parts of the Tile Saw while it is plugged in and running. 28. When cutting a large work piece make sure its entire length is prop- erly supported. If necessary , use a roller stand (not included) with larger work pieces. 29 ...

  • Chicago Electric 40315 - page 8

    Page 8 SKU 40315 For technical questions, please call 1-800-444-3353. situations that may occur . It must be understood by the operator that common sense and caution are fac- tors which cannot be built into this product, but must be supplied by the operator . Abrasive Cutting-Off Operation Safety W arnings 1. This power tool is intended to function ...

  • Chicago Electric 40315 - page 9

    Page 9 SKU 40315 For technical questions, please call 1-800-444-3353. cause injury beyond immediate area of operation. 1 1. Position the cord clear of the spin- ning blade. If you lose control, the cord may be cut or snagged and your hand or arm may be pulled into the spinning accessory . Avoid uninten- tional starting. Prepare to begin work before ...

  • Chicago Electric 40315 - page 10

    Page 10 SKU 40315 For technical questions, please call 1-800-444-3353. GROUNDING TO PREVENT ELECTRIC SHOCK AND DEA TH FROM INCORRECT GROUNDING WIRE CONNECTION: Check with a qualied electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding pr ...

  • Chicago Electric 40315 - page 11

    Page 1 1 SKU 40315 For technical questions, please call 1-800-444-3353. 2. Double insulated tools may be used in either of the 120 volt outlets shown in the preceding illustration. (See Outlets for 2-Prong Plug.) Extension Cords 1. Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extensio ...

  • Chicago Electric 40315 - page 12

    Page 12 SKU 40315 For technical questions, please call 1-800-444-3353. SPECIFICA TIONS Blade Diameter (Blade Not Included, Sold Separately) 7" (67393 7” Continuous Rim Diamond Blade Recommended) Arbor Diameter 1" Maximum Cutting Capacity 1” Thick, 12” Wide Electrical Requirements 120 V~ / 60 Hz / 5 A Single Phase T ilting Head 45° ...

  • Chicago Electric 40315 - page 13

    Page 13 SKU 40315 For technical questions, please call 1-800-444-3353. ing sure no hidden electric cords or cables are in the drilling path. 6. Once the mounting holes are drilled, align the four 7/16” wide x 3-1/2” long mounting slots in the base of the Inner Cover (16) with the four pre- drilled mounting holes in the work- bench. Secure the T ...

  • Chicago Electric 40315 - page 14

    Page 14 SKU 40315 For technical questions, please call 1-800-444-3353. OPERA TING INSTRUCTIONS Read the ENTIRE IMPORT ANT SAFETY INFORMA TION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. T ool Set Up TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power ...

  • Chicago Electric 40315 - page 15

    Page 15 SKU 40315 For technical questions, please call 1-800-444-3353. General Operating Instructions 1. Fill T ray (17) with water and carefully slide T ray under Blade. Make sure water level is deep enough to cover lower edge of Cutting Wheel Blade, but not so deep as to spill over edge of T ray . (See Figure 3, below .) 2. Loosen Star Knob (20) ...

  • Chicago Electric 40315 - page 16

    Page 16 SKU 40315 For technical questions, please call 1-800-444-3353. MAINTENANCE AND SER VICING Procedures not specically explained in this manual must be performed only by a qualied technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power Switch of the tool to its “OFF” position and unplug the tool from its e ...

  • Chicago Electric 40315 - page 17

    Page 17 SKU 40315 For technical questions, please call 1-800-444-3353. (not included, sold separately), making sure to install Blade according to indicated rotation direction on Blade. F. Replace the Outside Flange (7) and Nut (4). Use the Spanner (59) to hold the Outside Flange (7) while you tighten the Nut (4) securely with the Nut Driver (60). D ...

  • Chicago Electric 40315 - page 18

    Page 18 SKU 40315 For technical questions, please call 1-800-444-3353. P ARTS LIST Part Description Part Description Part Description 1 Front Cover 21 Power Switch 41 Motor Lead Wire 2 Screw (M4x10) 22 Switch Seal 42 Motor 3 W asher (M4) 23 Switch Cover 43 Rear Cover 4 Nut (M12) 24 Inlet Clip 44 Handle 5 Lock W asher (M12) 25 Rubber Collar 45 W ash ...

  • Chicago Electric 40315 - page 19

    Page 19 SKU 40315 For technical questions, please call 1-800-444-3353. ASSEMBL Y DIAGRAM Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only , and are not available individually as replacement parts . 18 ...

  • Chicago Electric 40315 - page 20

    Page 20 SKU 40315 For technical questions, please call 1-800-444-3353. 90 Day W arranty Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the dat ...

Fabbricante Chicago Electric Categoria Saw

I documenti che otteniamo dal fabbricante del dispositivoChicago Electric 40315 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Chicago Electric
- manuali per l’uso 40315
- schede prodotto Chicago Electric
- opuscoli
- o etichette energetiche Chicago Electric 40315
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Chicago Electric 40315.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Chicago Electric 40315, manuali di manutenzione, brevi manuali o manuali utente Chicago Electric 40315. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Chicago Electric 40315.

Manuali per l’uso simili

Manuale completo del dispositivo Chicago Electric 40315, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Chicago Electric 40315 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Chicago Electric 40315.

Il manuale per l’uso completo Chicago Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Chicago Electric 40315 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Chicago Electric 40315, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Chicago Electric 40315 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Chicago Electric 40315 - che ci dovrebbe aiutare nei primi passi durante l'uso Chicago Electric 40315
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Chicago Electric 40315
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Chicago Electric 40315 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Chicago Electric 40315?

Utilizza il modulo sottostante

Se non hai risolto il problema con Chicago Electric 40315 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Chicago Electric 40315 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)