Manuale per l’uso La Crosse Technology WS-9016U

31 pagine 0.8 mb
Scarica

Vai alla pagina of 31

Summary
  • La Crosse Technology WS-9016U - page 1

    WS-9016U Wireless 433 MHz Radio-controlled Sun/Moon Weather Station Instruction Manual ...

  • La Crosse Technology WS-9016U - page 2

    2 Topic Page Inventory of Contents/ Additional Equipm ent 3 About WWVB 4 Quick Set-Up Guide 5 Detailed Set-Up Guide Battery Installation 6 Program Mode Function Keys 7-8 LCD Screen 9 Manual Settings Sequence 9 LCD Contrast Setting 10 City Location Setting 10 Time Zone Sett ing 11 Daylight Saving Ti me (DST) Sett ing 11 WWVB O n/Off Setting 12 12/24 ...

  • La Crosse Technology WS-9016U - page 3

    3 INVENTORY OF CONTENTS 1. The indoor weather station (Fi gure 1). 2. One TX6U remote tem perature sensor with m ounting bracket (Figure 2). 3. Three each, ½” Philips screws. 4. One strip double-sided adhesive t ape. 5. Instruction m anual and warranty card. ADDITIONAL EQUIPMENT (not included) 1. Two, fresh AA 1.5V batteries for indoor weather s ...

  • La Crosse Technology WS-9016U - page 4

    4 ABOUT WWVB (Radio Controlled Time) The NIST (National Institute of Sta ndards and Technology—Time and Frequency Division) WW VB radio station is located in Ft. Collins, Co lorado and transmits the exact time signal conti nuously throughout the Unite d States at 60 kHz. The signal can be received up to 2, 000 miles away th rough the internal ant ...

  • La Crosse Technology WS-9016U - page 5

    5 QUICK SET-UP GUIDE Hint: Use good quality Alkaline Batteri es and avoid rechargeable batteries. 1. Have the indoor weather station and rem ote tem perature sensor 3 to 5 feet apart. 2. Batteries should be out of both units for 10 m inutes. 3. Place the batteries into the remote temperature sensor first then into the indoor weather station . (All ...

  • La Crosse Technology WS-9016U - page 6

    6 DETAILED SET-UP GUIDE I. Battery Installation A. Remote Temperature Sensor 1. Remove the mounting bracket. The bracket snaps on and off easily. 2. Remove the battery cover, by sliding the cover down. 3. Observing the co rrect p olarity install 2 AA batteries. The batteries will fit tigh tly (to avoid start-up problem s make sure they do not sprin ...

  • La Crosse Technology WS-9016U - page 7

    7 II. Program Mode Programming Note: If 30 seconds are allowed to pass or ei ther the IN or the OUT button is pressed during p r o gramming modes, the un it will set the last inform a tion entered—the display will stop flashing and return to normal time-date readings. A. Function Keys Weather Station: The Weather Station has 8 easy to use functi ...

  • La Crosse Technology WS-9016U - page 8

    8 3. MINUS (-) button • Decrease value in all setting modes • Decrease the digits • Stop the alarm duri ng alarm ringi ng 4. SUN/MOON button • Enter the sun/moon setting mode • Start the sun/moon t ime calcula tion of the selected city • Stop the alarm duri ng alarm ringi ng 5. ALARM SET button • Enter the alarm setting mode • Stop ...

  • La Crosse Technology WS-9016U - page 9

    9 B. LCD Screen The LCD screen is split into 5 sections displaying th e in formation for time and date, sun/moon data, indoor data, weather forecast and outdoor data. C. Manual Setting Sequence The following ma nual settings can be changed when pressing the “SET” button: • LCD contrast setting • City location setting • Time zone sett ing ...

  • La Crosse Technology WS-9016U - page 10

    10 LCD Contrast Setting The LCD contrast can be set with in 8 levels, from LCD 0 to LCD7 (the default setting is LCD 5 ): 1. Press and hold the “SET” button until the d ig it starts flash ing in the LCD. 2. Press and release the PLUS (+) or MI NUS (-) button to view all levels of contrast. 3. Select the desired LCD contrast. 4. Press and releas ...

  • La Crosse Technology WS-9016U - page 11

    11 Flashing Time Zone Setting The default (factory set) ti me zone of the indoor weather st ation is EST –5 (the default time zone for the default city, W ashington D.C.). To set a different time zone: 1. The current time zone value starts flashing on the LCD. 2. Press and release PLUS (+) or MINUS (-) button to set the time zone. 3. The range ru ...

  • La Crosse Technology WS-9016U - page 12

    12 Digits flashing Tower icon flashing Flashing WWVB ON/OFF Setting In areas where reception of the WWVB time is not possible the WW VB time reception function can be turned OFF. The clock will then work as a normal Quartz clock. (the default sett ing is ON). 1. The digit “ON” will start flash in g on the LCD. 2. Press and release the PLUS (+) ...

  • La Crosse Technology WS-9016U - page 13

    13 Manual Time Setting In case the indoor weather station cannot det ect the WWVB signal (for example due to disturbances, transmitting d istan ce, etc.), th e time can be manually set. The clock will then work as a n ormal Quartz clock. 1. The hour digit will start flashing on the LCD. 2. Press and release the PLUS (+) or MINUS (-) button to set t ...

  • La Crosse Technology WS-9016U - page 14

    14 Calendar Setting The default (factory set) date of the indoor weather station is 1. 1. in the year 2001. Once the radio-controlled time signal is recei ved the date is automatically updated. If the signals are not received the date can also be set manually. 1. The year starts flashing in the LCD. 2. Press and release the PLUS (+) or MINUS (-) bu ...

  • La Crosse Technology WS-9016U - page 15

    15 Digit flashing Snooze Setting The snooze time can be set from OFF to a m aximum time of 30 mi nutes. The default (factory) setti ng is OFF. 1. The digits “OFF” will start flashing in the LCD. 2. Press and release the PLUS (+) or MINUS (-) button to set the snooze t ime. Each pressing of the button will incr ease or decrease the snooze time b ...

  • La Crosse Technology WS-9016U - page 16

    16 Weather Forecast Icon Sensitivity Setting For locations with rapid changes of weat he r conditions, the weather ic ons can be set to a different level for fast er display of weather condit ions. 1. The current sensitivity valu e will start flashing. 2. Press and release the PLUS (+) or MINUS (-) button to set the weather sensitivity level. 3. Th ...

  • La Crosse Technology WS-9016U - page 17

    17 6. Press and release the PLUS (+) or MI NUS (-) button to set the alarm mi nute. 7. Press and release the “SET” button to confirm and exit the Alarm setting . Note: The maxim um alarm ring duration is 3 m inutes . The alarm setting can be activated or deactivated by pressing the “ALARM ON/OFF” button. The alarm icon will b e displayed on ...

  • La Crosse Technology WS-9016U - page 18

    18 Note: It will take a few seconds until the s un/moon data will be displayed. The display will return after 3 minutes to nor mal mode. The “CH” butt on can also be used to return im mediately to the normal display mode. If onl y a specific data is changed, e.g. only a different city is selected, the “SUN/MOON” button can be pressed to sta ...

  • La Crosse Technology WS-9016U - page 19

    19 WEATHER FORECASTING ICONS: Note: The weather forecast icons of this i ndoor weather station are a prediction of what the weather is going t o do in the next 12 to 20 hours. These are not indications of the current weat her. Weather icons in the fourth section of LCD can be displ ayed in any of the foll owing combinations: Sunny Cloudy with sunny ...

  • La Crosse Technology WS-9016U - page 20

    20 indoor weather station will be more accurate com pared to use in areas where the weather is stagnant m ost of th e time (for exam ple mostly sunny). If the indoor weather stati on is moved to another l ocation significant ly higher or lower than its initial standing point (for example from the ground floor to the upper floors of a house), disreg ...

  • La Crosse Technology WS-9016U - page 21

    21 TOGGLING AND RESETTING THE OUTDOOR RECORDINGS: 1. To toggle between the outdoor current, m axim um and m inimum temperature data and the times they were recorded press and release the “MAX/MIN R” button: • Once to show the maxim um outdoor t emperature data wi th the recorded time and date. • Twice to show the mi nimum outdoor te mperatu ...

  • La Crosse Technology WS-9016U - page 22

    22 if this is not done correctly and if the total time for set-up exceeds 6 minutes. SET-UP OF MULTIPLE UNITS 1. It is necessary to remove the batteries from all units cu rrently in operation. 2. Remove the battery covers to all remote temperature senso r units. 3. Place all remote temperature sensor units in a num eric sequential order. 4. In sequ ...

  • La Crosse Technology WS-9016U - page 23

    23 THE REMOTE TEMPERATURE SENSOR The remote tem perature sensor can be mounted i n two ways: • with the use of screw s • using the adhesive tape A. MOUNTING WITH SCREWS 1. Remove the mounting bracket from the remote temperature sensor. 2. Place the mounting bracket ove r the desired location. 3. Through the three screw holes of the bracket , ma ...

  • La Crosse Technology WS-9016U - page 24

    24 THE INDOOR TEMPERATURE STATION The indoor temperature st ation can be mounted i n two ways: • with the table stand • on the wall with the use of a wall hanging screw (not included) A. USING THE TABLE STAND The indoor temperature stati on comes wi th the table stand already mount ed. If you wish to use the table-stand all that is required is ...

  • La Crosse Technology WS-9016U - page 25

    25 City Listing (In order as they appear on left side of unit) Montgomery, Alabama Little Rock, Arkansas Phoenix, Arizona Los Angeles, California San Francisco, California Denver, Colorado Washington D.C. Jacksonville, Florid a Miami, Florida Atlanta, Georgia Des Moines, Iowa Boise, Idaho Chicago, Illinois Kansas City, Kansas New Orleans, Louisiana ...

  • La Crosse Technology WS-9016U - page 26

    26 Problem: No reception of WWVB time signal Solution : 1) Wait overnight for signal. 2) Be sure indoor weather station is at least 6 feet from any electrical devices, such as televisions, computers, or other radi o-controlled clocks. 3) Remove batteri es for five minute s, reinsert and leave alone without pressi ng buttons overnight. 4) If there a ...

  • La Crosse Technology WS-9016U - page 27

    27 MAINTENANCE AND CARE INSTRUCTIONS • Extreme tem peratures, vibration and shock shoul d be avoided to prevent damage to the units. • Clean displays and units with a soft, dam p cloth. Do not use sol vents or scouring agents. They m ay mark the di splays and casings. • Do not submerge in wat er. • Immediately rem ove all low powered batter ...

  • La Crosse Technology WS-9016U - page 28

    28 SPECIFICATIONS Temperature measuring range: Indoor: 32 ° F to 140 ° F with 0.1 ° F resolution. (0 ° C to 60 ° C with 0.1 ° C resolution) “OF” displayed if out side this range Outdoor: -21.8 ° F to 157.8 ° F with 0.2 ° F resolution. (-29.9 ° C to 69.9 ° C with 0.1 ° C resolu tion) “OF” displayed if out side this range Indoor r ...

  • La Crosse Technology WS-9016U - page 29

    29 WA RRA NTY INFORMATION La Crosse Technology, Ltd provides a 1-y ear limited w arranty on this product against manufacturing defects in ma terials and workmanship. This limited warranty begins on the original dat e of purchase, is valid only on products purchased and used in North America and only to the original purchaser of this product. To rec ...

  • La Crosse Technology WS-9016U - page 30

    30 PUBLIC INFORMATION. THIS PRO DUCT IS NOT A T OY. KEEP OUT OF CHILDREN’S REACH. This warranty gives y ou specific legal rights. You may also have other rights specific to your State. Some States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to y ou. For warranty work, ...

  • La Crosse Technology WS-9016U - page 31

    WS-9016U Cities List Montgomery, Alabama Little Rock, Arkansas Phoenix, Arizona Los Angeles, California San Francisco, California Denver, Colorado Washington D.C. Jacksonville, Florida Miami, Florida Atlanta, Georgia Des Moines, Iowa Boise, Idaho Chicago, Illinois Kansas City, Kansas New Orleans, Louisi ana Boston, Massachusetts Portland, Maine Det ...

Fabbricante La Crosse Technology Categoria Portable Radio

I documenti che otteniamo dal fabbricante del dispositivoLa Crosse Technology WS-9016U possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici La Crosse Technology
- manuali per l’uso WS-9016U
- schede prodotto La Crosse Technology
- opuscoli
- o etichette energetiche La Crosse Technology WS-9016U
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso La Crosse Technology WS-9016U.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione La Crosse Technology WS-9016U, manuali di manutenzione, brevi manuali o manuali utente La Crosse Technology WS-9016U. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto La Crosse Technology WS-9016U.

Manuale completo del dispositivo La Crosse Technology WS-9016U, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare La Crosse Technology WS-9016U dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti La Crosse Technology WS-9016U.

Il manuale per l’uso completo La Crosse Technology, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale La Crosse Technology WS-9016U - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice La Crosse Technology WS-9016U, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per La Crosse Technology WS-9016U che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo La Crosse Technology WS-9016U - che ci dovrebbe aiutare nei primi passi durante l'uso La Crosse Technology WS-9016U
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del La Crosse Technology WS-9016U
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio La Crosse Technology WS-9016U in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su La Crosse Technology WS-9016U?

Utilizza il modulo sottostante

Se non hai risolto il problema con La Crosse Technology WS-9016U con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con La Crosse Technology WS-9016U è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)