    W ARNING: If the information in these instructions are not followed exactly , a fi re or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be performed by a ...

  • Regency U39-NG1 - page 2

    2 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove REGENCY ® UL TIMA TE Direct V ent Freestanding Gas Stove T o the New Owner: Congratulations! Y ou are the owner of a state-of-the-art UL TIMA TE Direct V ent Gas Stove by FPI Fireplace Products International Ltd. The Regency ® Gas Series of hand crafted appliances has been designed t ...

  • Regency U39-NG1 - page 3

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 3 T ABLE OF CONTENTS SAFETY LABEL Copy of Safety Label ..................................................... 4 REQUIREMENTS MA Code - CO Detector ................................................ 5 INST ALLA TION Important Message ........................................................ 6 ...

  • Regency U39-NG1 - page 4

    4 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove This is a copy of the label that accompanies each UL TIMA TE Direct V ent Freestanding Gas Stove. We have printed a copy of the contents here for your review . The safety SAFETY LABEL label is located on the inside of the drop down pedestal door . Copy of Safety Label for U39 Gas Stove ...

  • Regency U39-NG1 - page 5

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 5 REQUIREMENTS 5.08: Modifica tions to NFPA-54, Chapter 10 (2) Revise 10.8. 3 by adding the follow ing additiona l requirements: (a) For all side wall hor izontally vented ga s fueled equipment in stalled in every dwelling, bui lding or structure used in whole or in part for residential ...

  • Regency U39-NG1 - page 6

    6 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove IMPORT ANT MESSAGE SA VE THESE INSTRUCTIONS The UL TIMA TE Direct V ent Freestanding Gas Stove must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the building authority having jurisdiction to determine the need f ...

  • Regency U39-NG1 - page 7

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 7 INST ALLA TION 8) Any safety glass removed for servicing must be replaced prior to operating the appliance. 9) T o prevent injury , do not allow anyone who is unfamiliar with the operation to use the fi replace. INST ALLA TION CHECKLIST 1) Loate your appliance. Refer to the following ...

  • Regency U39-NG1 - page 8

    8 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove For V ent T ermination requirements, see "Exterior V ent termination Locations" section. LOUVER INST ALLA TION 1) Attach the top & bottom louvers to the side stove panel using 2 screws per side. INST ALLA TION MANUF ACTURED MOBILE HOME ADDITIONAL REQUIREMENTS 1) Ensure th ...

  • Regency U39-NG1 - page 9

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 9 EXTERIOR VENT TERMINAL LOCA TIONS A = Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) C= Clearance to permanently closed window *(min. 12"/30cm) D= V ertical clearance to ventilated so ...

  • Regency U39-NG1 - page 10

    10 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Description Simpson Direct V ent Pro ® Simpson Direct V ent GS ® Discontinued Selkirk Direct-T emp™ American Me ...

  • Regency U39-NG1 - page 11

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 11 Description Simpson Direct V ent Pro ® Simpson Direct V ent GS ® Discontinued Selkirk Direct-T emp™ American Metal Products ® Amerivent Direct Metal-Fab ® Sure Seal Security Secure V ent ® Attic Insulation Shield 12” 46DV A-IS - N/A from FPI N/A N/A 4DAIS12 N/A SV4RSA Attic I ...

  • Regency U39-NG1 - page 12

    12 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove RIGID PIPE VENTING SYSTEMS Horizontal or V ertical Terminations Alternate Horizontal T er- mination Caps INST ALLA TION This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-V ent GS, Selkirk Direct-T emp, Ameri V ent Direct ven ...

  • Regency U39-NG1 - page 13

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 13 INST ALLA TION PRECAUTIONS These venting systems are engineered products that have been designed and tested for use with the U39-NG1, and U39-LP1. The warranty will be voided and serious fi re, health or other safety hazards may result from any of the following actions: 1) Installati ...

  • Regency U39-NG1 - page 14

    14 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove Horizontal V enting with T wo (2) 90 o Elbows Option V H + H1 A) 3' Min. 2' Max. B) 5' Min. 3' Max. C) 8' Min. 4' Max. With these options, maximum total pipe length is 30 feet with minimum of 8 feet total vertical and maximum 4 feet total horizontal. Plea ...

  • Regency U39-NG1 - page 15

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 15 INST ALLA TION DV ST OVE HORIZONT AL VENT KIT INST ALLA TION Minimum Installation Height: U39: 59-3/4" ( 1518mm) DV ST OVE HORIZONT AL VENT KIT (# 946-1 16 & #946-216) DV Stove Horizontal V ent Kit (2 ft. Part # 946-1 16 or 4 ft. Part # 946-216) includes all the parts needed ...

  • Regency U39-NG1 - page 16

    16 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove INST ALLA TION Note: if the centerline cannot be met, the adjustable sections will have to be cut. e) Cut the 2 ft. or 4 ft. section of rigid pipe to length. Ensure that the pipe length when cut will seat onto both the starter collar and the 90 o elbow . Crimped section of rigid pipe ...

  • Regency U39-NG1 - page 17

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 17 Alternate Horizontal T ermination Caps Dura-V ent Basic Horizontal Kit # 970 1 90 o Elbow 1 W all Thimble Cover 1 Horiz. Sq. T erm. Cap DURA-VENT TERMINA TION KIT Planning Y our Dura-V ent Installation There are two basic types of Dura-V ent Direct V ent System installations: horizont ...

  • Regency U39-NG1 - page 18

    18 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove NOTE: For Snorkel terminations in ABOVE grade installations, follow national or local code requirements. Diagram 3a Note: Riser V ent is only for use in above grade terminations. U39: 59-3/4" (1518mm) Diagram 2 Note: a) The horizontal run of vent should have a 1/4 inch rise for e ...

  • Regency U39-NG1 - page 19

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 19 Diagram 10 Diagram 9 Diagram 8 Diagram 7 Diagram 6 7) Install the Wall Thimble in the center of the 10" square and attach with wood screws. 8) Slide the decorative wall thimble up to the wall surface being careful not to scratch the paint and attach with screws provided. Apply de ...

  • Regency U39-NG1 - page 20

    20 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove INST ALLA TION Diagram 1 1: The upper half of the fl ashing is installed under the roofi ng material and not nailed down until the chimney is installed. This allows for small adjustments. 4) Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance ...

  • Regency U39-NG1 - page 21

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 21 INST ALLA TION Using a level, make sure the support is vertical. If the support extends above the roof, cut it fl ush with the top of the roof. Nail the support to the frame opening using (8) 3" spiral nails or #8 x 1-1/2" screws. Note: If you are using a 6" square sup ...

  • Regency U39-NG1 - page 22

    22 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove Converting a Masonry Chimney Important: The existing masonry flue opening needs to have an area of at least a 36 sq. in. to insure proper intake/exhaust fl ow. 1) Before cutting any holes, assemble the desired sections of black direct vent pipe to determine the center of the masonry ...

  • Regency U39-NG1 - page 23

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 23 U39-NG1: For 0 to 2000 feet altitude U39-LP1: For 0 to 4500 feet altitude Burner Inlet Orifi ce Sizes: Natural Gas Propane Burner #32 #50 Max. Input - Natural Gas/Propane 38,000 Btu/h Min. Input - Natural Gas/Propane 20,000 Btu/h Supply Pressure Natural Gas min. 5" w .c. Propane ...

  • Regency U39-NG1 - page 24

    24 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove CONVERSION KIT# 731-969 FROM NG T O LP THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 1) Shut off the gas supply . 2) Open the front door and carefully remove the logs and lava rock. Pilot assembly is now accessible for steps 4) to 10). ...

  • Regency U39-NG1 - page 25

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 25 16) Pull off the pilot cap to expose the pilot orifi ce. 17) Unscrew the pilot orifi ce with the allen key and replace with the LPG pilot orifi ce in the kit. 19) Reinstall new burner orifi ce LPG stamped #50 and tighten. 20) Reverse steps 3) to 2). 21) Attach the label "This ...

  • Regency U39-NG1 - page 26

    26 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 7) Reversing step 2 and secure the control panel back onto the stove pedestal with the screws. 9) The Ground Wire, DC Sparker Ignition Wire and Piezo Spark Wire all go through the hole located on the pedestal back cover . 10) Put on the plastic split bushing. 11 ) Attach the Piezo Ign ...

  • Regency U39-NG1 - page 27

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 27 GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from v ...

  • Regency U39-NG1 - page 28

    28 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove AERA TION ADJUSTMENT The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. U39 with 38,000 Btu/h U39-NG1 Natural Gas: 1/4" open U39-LP1 Propane: 1/2" open U39 with 30,000 Btu/h U39-NG1 Natural Gas 3/16" open U39-LP1 Pr ...

  • Regency U39-NG1 - page 29

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 29 LOG SET INST ALLA TION INST ALLA TION Embers Embers The "02" refer numbers (i.e. 02-65) are molded into the rear of each log. Note: Install Optional Brick Panels prior to installing logs. 1) Carefully remove the logs from the box and unwrap them. The logs are fragile, handle ...

  • Regency U39-NG1 - page 30

    30 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove Cutout Pin D)02-46 B)02-56 A)02-65 7) Place the Left T op Log D)02-46 on the pin on Log B)02-56 and on top of the cutout on Log A)02-65. E)02-45 C)02-44 8) Place Front Right Log E)02-45 on the two pins as shown. 9) Place the lava rock in the area between the left and right logs, leavi ...

  • Regency U39-NG1 - page 31

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 31 Cutout Notch F)02-47 E)02-45 A)02-65 11 ) Place the notch in Center Log F)02-47 over Log E)02-45 and across the cutout on Log A)02- 65. Notch E)02-45 Bracket A)02-65 The bottom right edge of Log G)02-48 must sit snugly against the bracket Side V iew G)02-48 E)02-45 F)02-47 12) Positio ...

  • Regency U39-NG1 - page 32

    32 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove WIRING DIAGRAM CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous W ARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard ...

  • Regency U39-NG1 - page 33

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 33 14 GA. 16 GA. 18 GA. 20 GA. 22 GA. 50 Ft. 32 Ft. 20 Ft. 12 Ft. 9 Ft. Recommended Maximum Lead Length (T wo-Wire) When Using W all Thermostat (CP-2 System) Wire Size Max. Length Thermostat Wire T able OPTIONAL W ALL THERMOST A T A wall thermostat may be installed if desired. Connect th ...

  • Regency U39-NG1 - page 34

    34 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove OPERA TING INSTRUCTIONS SHUTDOWN INSTRUCTIONS 1) Use the Burner ON/OFF switch, thermostat or remote control to turn off the burner . 2) Push in the PILOT knob slightly and turn clockwise to off. Do not force. 3) Turn of f all electric power to the appliance if service is to be perform ...

  • Regency U39-NG1 - page 35

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 35 1) Push in gas control knob slightly and turn to “PILOT” position. 2) Push in control knob all the way and hold in until the pilot lights up. Continue to hold the control knob in for about 20 seconds after the pilot is lit. Release knob. 3) Push in gas control knob slightly and tu ...

  • Regency U39-NG1 - page 36

    36 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the valve before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year . When cleaning the logs, use a soft clean paint brush as the ...

  • Regency U39-NG1 - page 37

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 37 Mitred Glass Replacement Removing Glass 1) Remove the door from the unit and place on a soft surface to prevent scratching. 2) Pull out the door gasket. 3) Remove the 24 nuts holding the glass retainers in place. Do not remove the nuts underneath the retainers. 4) Remove the door catc ...

  • Regency U39-NG1 - page 38

    38 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove MAINTENANCE F AN MAINTENANCE If your fan requires maintenance or replacement, access to the fan is through the plate on the rear wall of the fi rebox. NOTE: the unit MUST NOT be operated without the fan access panel securely in place and correctly sealed. IMPORT ANT : These fans coll ...

  • Regency U39-NG1 - page 39

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 39 REMOVING V AL VE 2) Undo the six screws holding the control panel in place. 3) Disconnect all wires from the back of the panel and then remove panel. Y ou should lay the panel on a soft cloth so it doesn't get marked up. See diagram below . 6) Remove the two outside frame pieces ...

  • Regency U39-NG1 - page 40

    40 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove P ARTS LIST 30) 630-021 Fan Access Panel 31) 730-019 Rear Panel 32) 730-565 Firebox Baffl e/Restrictor Assy 33) 630-520 False T op Assembly 36) 936-194 Gasket-Starter Collar/Air Passage 37) * Gasket-Flue Collar/Starter Collar 38) 820-058 Pedestal Base Cover 39) * Gasket - Air Passage ...

  • Regency U39-NG1 - page 41

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 41 BURNER & LOG ASSEMBL Y 51) 910-241 Burner ON/OFF Switch (3-way) 52) 910-190 Piezo Ignitor & Nut 53) 904-586 Knob for Fan Speed Control 54) 910-373 Knob - Pilot V alve Extension 55) 910-372 Flame Adjusting Knob 56) 908-646 Control Panel Decal 57) 650-220 Control Panel Plate 58) ...

  • Regency U39-NG1 - page 42

    42 Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove P ARTS LIST DOOR ASSEMBLIES Part # Description 730-923 Brush Nickel Mitred Door - Complete 730-924 Gold Mitred Door - Complete 730-926 Black Mitred Door - Complete 730-932 Gold W rap Door - Complete 730-928 Gold Panel Door - Complete 101) 650-920 Door Gasket Kit 105) * Ceramic Paper 1 ...

  • Regency U39-NG1 - page 43

    Regency ® U39 UL TIMA TE Direct V ent Freestanding Gas Stove 43 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our facility . FPI Fireplace Products International Ltd. is pleased to extend this lim ...

  • Regency U39-NG1 - page 44

    Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ...

Fabbricante Regency Categoria Stove

I documenti che otteniamo dal fabbricante del dispositivoRegency U39-NG1 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Regency
- manuali per l’uso U39-NG1
- schede prodotto Regency
- opuscoli
- o etichette energetiche Regency U39-NG1
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Regency U39-NG1.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Regency U39-NG1, manuali di manutenzione, brevi manuali o manuali utente Regency U39-NG1. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Regency U39-NG1.

Manuali per l’uso simili

Manuale completo del dispositivo Regency U39-NG1, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Regency U39-NG1 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Regency U39-NG1.

Il manuale per l’uso completo Regency, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Regency U39-NG1 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Regency U39-NG1, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Regency U39-NG1 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Regency U39-NG1 - che ci dovrebbe aiutare nei primi passi durante l'uso Regency U39-NG1
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Regency U39-NG1
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Regency U39-NG1 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Regency U39-NG1?

Utilizza il modulo sottostante

Se non hai risolto il problema con Regency U39-NG1 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Regency U39-NG1 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)