Manuale per l’uso Procom ML300HGA

21 pagine 0.44 mb
Scarica

Vai alla pagina of 21

Summary
  • Procom ML300HGA - page 1

    1 BLUE FLAME VENT-FREE PROP ANE/LP GAS GARAGE HEA TER OWNER ’ S OPERA TION AND INST ALLA TION MANU AL ML 300HGA ML 300T G A NON-THERMOST A T AND THERMOST A T MODEL Important Safety Information..................................... 2 Fresh Air for Combustion and V entilation ............... 4 Installation............................................ ...

  • Procom ML300HGA - page 2

    2 IMPORT ANT SAFETY INFORMA TION Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible fo r use with other gases. 2. Do not place propane/LP supply tank(s) inside any ...

  • Procom ML300HGA - page 3

    3 PRODUCT FEA TURES SAFETY DEVICE A standard requirement for all vent-free room heaters. This heater has a pilot with an Oxygen Depletion Sensor(ODS) safety shutoff system. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM This heater is equipped with a piezo ignitor. This system requires no matches, batteri ...

  • Procom ML300HGA - page 4

    4 FRESH AIR FOR COMBUSTION AND VENTILA TION PRODUCING ADEQUA TE VENTILA TION The following are excerpts from National Fuel Gas Code. NFP A 54/ANS Z223.1, Section 5.3. Air for Combustion and V entilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually T ight Construction 2. Unconfined Space 3. Conf ...

  • Procom ML300HGA - page 5

    5 W ARNING: Rework worksheet, add- ing the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces. VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must p ...

  • Procom ML300HGA - page 6

    6 VENTILA TION AIR V entilation Air From Outdoors Provide extra fresh air by using ventilation grills or duels: Y ou must provide two permanent openings: one within 12 " of the ceiling and one within 12 " of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces ...

  • Procom ML300HGA - page 7

    7 INST ALLA TION Figure 8 - Mounting Bracket Clearances Figure 7 - Removing Lower Front Panel Of Heater Figur 4 -Mounting Clearances As V iewed From Front Of Heater W ARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from floor, ceiling, and joining wall. IMPORT ANT : V ent-free heaters add moisture t ...

  • Procom ML300HGA - page 8

    8 INST ALLA TION Figure 1 1 - Mounting Heater Onto Mounting Bracket Figure 9 - Folding Anchor Figure 10 - Popping Open Anchor Wing For Thin Walls Attaching Mounting Bracket T o W all Note: W all anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater. Attaching T o Wall Stud Method For attaching m ...

  • Procom ML300HGA - page 9

    9 INST ALLA TION CONNECTING TO GAS SUPPL Y W ARNING: A qualified service person must connect heater to gas supply. Follow all local codes. W ARNING: This appliance requires a 3/8 " NPT (National Pipe Thread) inlet connection to the pressure regulator. CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an exte ...

  • Procom ML300HGA - page 10

    10 Figure 15 -Equipment Shutoff V alve CHECKING GAS CONNECTIONS W ARNING: T est all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. W ARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. Pres ...

  • Procom ML300HGA - page 11

    1 1 Figure 17 - Control Knob in The OFF Position Figure 18 - Pilot  LIGHTING  INSTRUCTIONS 1. STOP! Read the safety information on the side of heater. 2. Check that gas supply to heater is on. 3. Push in gas control knob slightly and turn clockwise to the OFF position. NOTE : Knob cannot be turned from " PILOT " to " OFF " ...

  • Procom ML300HGA - page 12

    12 OPERA TING YOUR HEA TER NON-THERMOST A T MODEL ML300HGA  FOR YOUR SAFETY  READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these ...

  • Procom ML300HGA - page 13

    1 3 Figure 21 - Correct Pilot Flame Pattern Figure 22 - Incorrect Pilot Flame Pattern Figure 24 - Incorrect Burner Flame Pattern Figure 23 - Correct Burner Flame Pattern BURNER FLAME P A TTERN Figure 23 shows a correct burner flame pattern. Figure 24 shows an incorrect burner flame pattern. If pilot flame pattern is incorrect, as shown in Figure 24 ...

  • Procom ML300HGA - page 14

    14 TROUBLESHOOTING Note : All troubleshooting items are listed in order of operation. W ARNING: Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit. OBSERVED PROBLEM When ignitor button is pressed in, there is no spark at ODS/pilot. ...

  • Procom ML300HGA - page 15

    1 5 TROUBLESHOOTING Continued OBSERVED PROBLEM Burner(s)does not light after ODS/pilot is lit. Delayed ignition of burner(s). Burner backfiring during combustion. Y ellow flame during burner combustion. Slight smoke or odor during initial operation. Heater produces a whistling noise when burner is lit. Heater produces a clicking/ticking noise just ...

  • Procom ML300HGA - page 16

    16 TROUBLESHOOTING Continued W ARNING: If you smell gas  Shut off gas supply .  Do not try to light any appliance.  Do not touch any electrical switch; do not use any phone in your building.  Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.  If you cannot reach your gas supplier, ...

  • Procom ML300HGA - page 17

    1 7 SPECIFICA TIONS Btu(available) Gas T ype Ignition Pressure Regulator Setting Inlet Gas Pressure* (inches of water) Maximum Minimum Dimensions, Inches (HxWxD) Heater Carton Weight (pounds) Heater Shipping ML300HGA 15,000/28,000 Propane/LP Only Piezo 8 " W.C. 14 " 11 " 23 1/2 × 26 5/8 × 8 26 1/2 × 28 1/2 × 91/4 26 31 ML300TGA 1 ...

  • Procom ML300HGA - page 18

    18 ILLUSTRA TED P ARTS BREAKDOWN ML300TGA ...

  • Procom ML300HGA - page 19

    1 9 P ARTS LIST ML300TGA This list contains replaceable parts used in your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts 17 on page of this manual. KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 24_1 24_2 25 26 27 ML300TGA P ART NO. MB10002 MB09001 MB1 1002 ML089-01 ML084-01 ...

  • Procom ML300HGA - page 20

    20 ILLUSTRA TED P ARTS BREAKDOWN ML300HGA ...

  • Procom ML300HGA - page 21

    2 1 P ARTS LIST ML300HGA This list contains replaceable parts used in your heater. When ordering replacement parts, follow the instructions listed under Replacement Parts on page 17 of this manual. KEY NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 28-1 28-2 29 30 31 ML300HGA P ART NO. MB10003 MB09001 MB1 1002 ML089- ...

Fabbricante Procom Categoria Gas Heater

I documenti che otteniamo dal fabbricante del dispositivoProcom ML300HGA possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Procom
- manuali per l’uso ML300HGA
- schede prodotto Procom
- opuscoli
- o etichette energetiche Procom ML300HGA
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Procom ML300HGA.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Procom ML300HGA, manuali di manutenzione, brevi manuali o manuali utente Procom ML300HGA. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Procom ML300HGA.

Manuali per l’uso simili

Manuale completo del dispositivo Procom ML300HGA, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Procom ML300HGA dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Procom ML300HGA.

Il manuale per l’uso completo Procom, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Procom ML300HGA - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Procom ML300HGA, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Procom ML300HGA che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Procom ML300HGA - che ci dovrebbe aiutare nei primi passi durante l'uso Procom ML300HGA
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Procom ML300HGA
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Procom ML300HGA in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Procom ML300HGA?

Utilizza il modulo sottostante

Se non hai risolto il problema con Procom ML300HGA con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Procom ML300HGA è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)