    SERVICE MANUAL (TROUBLE SHOOTING AND REPAIRING TIPS) Fourth Edition – February 2006 CONSERV REFRIGERATOR MODELS 375 / 1200 SERIES ( OLD & NEW) ...

  • Equator 375 - page 2

    ...

  • Equator 375 - page 3

    Y our Equator appliance is protected by this warranty under normal, personal, family or household use (1 Y ear), and limited commercial use (90 days) in the USA and Canada. W ARRANTY EXCLUSIONS . . . Equator Corporation undertakes to the consumer-owner to repair or , at Equator Corporation’s option, to replace any part of this product which prove ...

  • Equator 375 - page 4

    2. ...

  • Equator 375 - page 5

    Disturbance Cause Trouble-Shooting Re m edy Unit does not refrigerate or freeze, compressor does not operate. Wall socket i s dead. Check instal lati on. Install new fuse if necessary . Inform user. Ma ins cab le is defective. See section 1.2: Troubl e- shooting i n the electri cal circuit . Repair or replace socket or mains cable. Thermostat i s d ...

  • Equator 375 - page 6

    D is tur ba nc e C a us e T r o uble -S ho o ting R e me dy O i l p rese n t i n sy stem af t er h or i z on t al tra nsp o rt. Q u es t i on u s er abou t m ode of t r an spor t at i on an d t i m e i n t er v al b et ween in s t a lla t io n a n d s t a r t - u p . L et u n i t st an d f or s ev er al ho ur s a t w a r m t em perat u r e an d t r ...

  • Equator 375 - page 7

    Disturbanc e Cause Troubleshooting Rem edy Defective thermostat. 1.Turn thermostat knob to zero. 2.Compressor continues to run. 3.Dismount brown wire. 4.Compressor continues to run. 5.Compressor stops. 4.Check internal wiring for short circuit (fast- freeze switch). 5.Replace thermostat. Compressor starts normally but stops again. Extrem ely high v ...

  • Equator 375 - page 8

    Ditrubanc e Cause Trouble-shooting R eme dy No-Frost Check if blade is locked mechanically. Fittings for fa n or air guiding duct are adjusted or replaced. Check if bl ade is fix ed correctly on shaft. Blade must turn so that air flow only can be sucked in and blown out in the right places. Blade must cover 10mm of shaft end, on two-step fan 14mm. ...

  • Equator 375 - page 9

    Disturbanc e Cause Trouble-shooting Rem edy Ic e blockage in capillary tube. Heat injection area on evaporator with cloth with hot water. I f refrigerant now can be h e a r dt of l o wm o r e quickly through t he sy stem, ice blockage in capillary tube is indicated. Alternatively , stop compressor and let evaporator defrost and start compressor aga ...

  • Equator 375 - page 10

    D is t urba nc e C a us e T r o uble - s ho o ting R e me dy Un i t h as recen t l y b een fille d w it h la r g e qu an t i t i es of f ood. Q u es t i on u se r abou t u se of u n i t i m m edi at el y pr i or t o s e r v ic e c a ll. In f o rm use r a b o u t th e pr obl em s ca u se d by t h i s . I n st r u ct u ser ab ou t u se of f ast - f r ...

  • Equator 375 - page 11

    1.2. T rou ble-S ho oting in th e E lectric Circu it. Befor e sy stematic tr ouble- shooting is c omm enced, chec k to ensure that: - The fu ses are intact. - The corr ect volt age has be en used (vo!t rnete r). - The electrical equ ipm ent used is su itable for the cam - pressOr. - The w iring has b een correcU y installed (com pare with wiring di ...

  • Equator 375 - page 12

    1.3. Check ing for Leak age to Frame For checking w hether there is leakag e between th e live parts and the fram e, the insulation resistan ce can be tested usin g an ohmm eter , megg er or high-v oltage testing device. An ohm meter can be used for a rough check. When investigating the w ir es on the unit, a clamp from the ohm meter is placed on t ...

  • Equator 375 - page 13

    Starting device with HST Connect a voltm eter b etween terminals 10 and 13 on the start- ing device. If no voltage can be meas ured, either the m ains cable or the socket is defective. Connect a voltm eter b etween terminals 10 and 14 on the start- ing device, It n o voltage can be m easured, a def ective ther- mostat or th ermostat w iring is indi ...

  • Equator 375 - page 14

    1.6. The PTC Starting Device It should be noted that starting d evice 1 03N001 2, which is used for the f reezing com pressor of refrig erator/freezer uprigh ts, is installed differently than is starting device 1 03N001 1, which is used for the refrigeratin g compres sor. On starting device 1 03N001 2, the N terminal is separated from the connectio ...

  • Equator 375 - page 15

    1 .7. Using a Manometer in Trouble-Shooting The pressure in a refrigerating system is directly dependent on the tem perature. For this reason, the manom eter can indicate both tem perature in degrees C elsiu s and pressure in bar. By m ounting a m anometer on the suction s ide of the compres- sor ~process ppe~. th e tem perature in t he evaporat or ...

  • Equator 375 - page 16

    Exam ples of troubl e-sh ooting u sing a m anom eter on the suc - tion side (process pip e) and a service valve: 1 . The system is blocked. The suc tion pr essure i s very low. Pressure equalizing takes place very slow ly or not at all. Cause: Ice blockage in the capillary tube at the filter or blockag e in th e sy stem for other reas ons. S ee tro ...

  • Equator 375 - page 17

    2. MAKING REPAIRS TO THE REFRIGERATING SYSTEM 2.1. Opening the Refrigerating System with Refrige- rant R600a (Isob utane) for Repai rs The Possibility of Fire/Explo sion exists Therefore, it is important to pay attention to the following points before commencin g repairs o f the refrigerating sy stem : 1. The serviceman is fam iliar with the danger ...

  • Equator 375 - page 18

    Actual Evacu ation After m ounting of the filling hose, the sy stem is ready f or the actual evacuation. Ev acuate until a s table vacuum of 1 mbar has been reached. Check for stability of the vacuum by closing the valve for t he vacuum pump (12 ). I f the vacuum gauge need le fall s appreciably, possible leakage in the sy stem is indicated. When a ...

  • Equator 375 - page 19

    First Evacuation of Ap pliances with R600a in the System 1. Drilling and tapping of filter dr ier, after thorough cleaning where the gasket o f the tongs must be tight. 2. Mount the hos e - open th e valv e. The sy stem can then be blown through w ith nitrogen (see section: T he Blowing Pro cess). 3. Clo se the valve aft er pr essure e quali zatio ...

  • Equator 375 - page 20

    The Blow ing Proc ess of the System. the Filling Sta - tion and the Vacuum Pumo and Opening of the Sys- tem 7. Dr illing and tapping of the pro cess pipe. 8. Connec t dry nitro gen and eq ualiz e the pr essure in the sy stem. 9. Open the valv e on th e tongs at the filter dri er and the spherical valve (18). 10. Open the valve for the filling stati ...

  • Equator 375 - page 21

    Actual Evacuation and Filling of R600a 1. Mounting of the filling hose w ith spherical valve - see fig. 7. Thereafter, ev acuate. 2. T esting of the m icroscales with a weight. 3. Connect the refrigerant tank to the filling hose (16), and open the valve (9). Evacuate the f illing hose and the m anifold by open ing th e valve for the v acuum pum p ( ...

  • Equator 375 - page 22

    2.1.1. Opening the Re frigerating System for Repairs with Recovery of Refrigerant. If a hermetic refrigerating sy stem is to function correctly and have a reasonably long life, it is essen tial that the amoun t of impurities pre-sent in the system , i.e. moisture, foreign gases, dirt, etc., be kept at a m inim um . This fact must be taken into cons ...

  • Equator 375 - page 23

    Pinc h the cha rging p ipe with p lier s. Remove t he ser vice va lve and so lder t he hole to gethe r. Brush of f all solderin gs in th e sys tem an d check for possibl e leakage w ith an electronic leak detector. Check the pressu re side when the compressor is in op eration and the suction side w hen the system is pressure equalized. Coat the are ...

  • Equator 375 - page 24

    Evacuation with Recovery of Refrigerant 1. Drillin g an d tapping of filt er drier aft er thorou gh clea ning where the gasket of the to ngs must be tight. 2. Mount the refrig erant bag - open the valve. 3. Close the valve aft er pr essure e qual izing-d ismount the refrigerant bag . 4. Mount the ref rigerant bag on th e vacuum pum p outlet. 5. Mou ...

  • Equator 375 - page 25

    Opening the System 7. Drilling and tap ping of process p ipe. 8. Connect dry nitrog en and equal ize the pres sure. 9. Open the system w ith cap illary tube scissors and remove the drilling and tapping valv e. The tongs are removed from th e used filter drier and dry n itrogen (N2) is now b lown through the process pipe and into the system (see Sec ...

  • Equator 375 - page 26

    2.1.2. Em ptying used Refrigerant to Press ure Vessel from Refrigerant Bag Connect the suction valve on the emptying un it with hose to the outle t valve o n the empt ying rack fo r re frige rant b ags. O pen t he main v alve and the valve f or the bags to be emptied. Connec t the pre ssure valve o n the emptying unit to the vessel for used r efrig ...

  • Equator 375 - page 27

    2.1.3. Openin g the Refrigeratin g System with Refrigerant R134a for Repai rs As R134a has oth er properties than the R12 used till now , it is important to note the follow ing before opening the herm etic refrigerating sy stem: 1. Service Tools Do not use ser vice to ols that have b een used fo r chlo rine- conta ining refr iger ants be cause micr ...

  • Equator 375 - page 28

    2.2. Replacing the Filt er Drier Some m oisture and impurities w ill alway s b e accumulated in the filter drier, both fro m residue left in t he system a fter installation and from contamin ation given off by the compres- sor, pipe sy stem and refrigerant. Wh en repairs are m ade to the refrigerating sy stem, the filter w ill often be unable to ab ...

  • Equator 375 - page 29

    Capillary tube broken off without the use of special-purp ose pliers. Capillary tube bro ken off using special-purpose pliers or capillary tube scissors. In order to ensure an efficient utilization of the filter drier, it should be positioned w ith an inclination of at least 15° and w ith the capillary tube lowered. 27. ...

  • Equator 375 - page 30

    2.3. Replacin g the Com pressor If trouble-shooting in the electric cir cuit or volumetric meas uremen ts indicate that th e compress or is defective, a new compressor must be installed. The follow ing procedure is to be used: Ensure that the n ew com pressor is ready for installation. Replace the electrical equ ipmen t. Clean a g ood area of the p ...

  • Equator 375 - page 31

    2.4. Replacin g the Evaporator The pipe system s of all Vestfrost heat exch angers are m ounted in plastic tubing with a diameter of 18/14.6 mm. It is therefore necessary to str aighten out the suction pip e and capillary tub e w hen an evaporator is to be replaced. Dismounting: 1. a) Refrig erator evaporator: Release t he evaporator by removi ng t ...

  • Equator 375 - page 32

    2.5. Replacin g the Therm ostat Uprights Dismoun t the phial tube and straighten out the phial. Draw off the insul ation, if any , around the phial. The phial can now be drawn out o f the lead-in pip e from th e back of the unit. After th e plug h as been rem oved from the socket, rem ove the cover for th e top panel and th e panel box. Remove the ...

  • Equator 375 - page 33

    Position ing of the Th erm ostat Phial in NFG 307 from Serial No. 501----- In ord er to e nsure the p rop er funct ioning o f the thermosta t 90 mm of the free end of the capillary tube is to serve as th ermostat phial. In case of failing thermostat functionin g and a po ssible replacemen t of the therm o stat, be sure that th e phial part is place ...

Fabbricante Equator Categoria Refrigerator

I documenti che otteniamo dal fabbricante del dispositivoEquator 375 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Equator
- manuali per l’uso 375
- schede prodotto Equator
- opuscoli
- o etichette energetiche Equator 375
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Equator 375.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Equator 375, manuali di manutenzione, brevi manuali o manuali utente Equator 375. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Equator 375.

Manuali per l’uso simili

Manuale completo del dispositivo Equator 375, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Equator 375 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Equator 375.

Il manuale per l’uso completo Equator, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Equator 375 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Equator 375, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Equator 375 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Equator 375 - che ci dovrebbe aiutare nei primi passi durante l'uso Equator 375
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Equator 375
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Equator 375 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Equator 375?

Utilizza il modulo sottostante

Se non hai risolto il problema con Equator 375 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Equator 375 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)