Manuale per l’uso Omega DPF500 Series

18 pagine 2.08 mb
Scarica

Vai alla pagina of 18

Summary
  • Omega DPF500 Series - page 1

    omega.com e-mail: info@omega.com Fo r la te st p ro du ct m an ua ls : omegamanual.info D P F 5 0 0 S e r i e s R a t e m e t e r / T o t a l i z e r Shop online at U ser ’ s Guide ...

  • Omega DPF500 Series - page 2

    Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canad ...

  • Omega DPF500 Series - page 3

    T able of Contents i Page Chapter 1 Introduction 1.1 Unpacking ...................................................................................................................... 1 1.2 Description ..................................................................................................................... 1 1.3 Features ................. ...

  • Omega DPF500 Series - page 4

    ii THIS P AGE INTENTIONALL Y BLANK ...

  • Omega DPF500 Series - page 5

    1 Chapter 1 Introduction 1.1 Unpacking Remove the Packing List and verify that you have received all equipment. If you have any questions about the shipment, please call OMEGA Customer Service Department. When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immed ...

  • Omega DPF500 Series - page 6

    2 Chapter 2 Installation 2.1 Battery Installation: All DPF500 models are shipped without the battery(ies) installed. This preserves battery life when the unit is not in service. When using external DPF5-BP , mount within 12" and plug connector into 3 position square posts (see Fig 1). Polarity is not a concern because center is common. T o ins ...

  • Omega DPF500 Series - page 7

    3 DPF503 DPF502 DPF501 DPF5-BP Accessory 2.3 Dimensions Dimensions are in inches (mm) Dimensions are in inches (mm) Dimensions are in inches (mm) Dimensions are in inches (mm) 4.92 (125) 4.33 (1 10) 4.33 (110) #8 Screw Mounting holes molded directly under cover screws. Max. screw head .29" (T yp. 4 places) E M .98 (25) 1.97 (50 ) .1 8 ( 5) .43 ...

  • Omega DPF500 Series - page 8

    4 Severa l typical applicati ons of the DPF500 are shown below . Please observe that the various pulse inputs and power options may be intermixed in many ways to solve common applications. The isolated pulse output may be freely used so long as proper polarity is observed. Caution : When 4-20 mA loop option is provided, the power wiring to the loop ...

  • Omega DPF500 Series - page 9

    5 Chapter 3 20 Point Linearization (-LIN option) 3.1 20 Point Linearization Operation (-LIN option) A 20 point linearization table is used to construct a curve describing the relationship of K-Factor and input frequency . The measured input frequency is used to access the table. A linear interpolation of adjacent point pairs is used to arrive at th ...

  • Omega DPF500 Series - page 10

    6 4.1 Explanation of Display Prompts (continued) fr# : (frequency for point #) This prompt will only appear when 20 point selected. It sets the frequency for each of the 20 points (#). Press the ↑ key to increment each digit. Press the ← key to step to the next digit to the left. Press the E key to enter the desired frequency for point #. faC# ...

  • Omega DPF500 Series - page 11

    7 4.1 Explanation of Display Prompts (continued) oUt HI : (out high) Sets the high setting for the 4-20 mA analog output. Key in the high rate value at which the unit will output 20 mA. Press the ↑ key to increment each digit. Press the ← key to step to the next digit to the left. Press the E key to enter the displayed out hi value. pUlscale : ...

  • Omega DPF500 Series - page 12

    8 4.2 Programming Flowchart RA TE RA TE RA TO T A L CLR ToT FDEC 12345678 M RUN MODE CLEAR T OT AL OT AL OT F ACT OR DECIMAL FAC 100 F ACT OR 0000 ent Code ENTER CODE If panel lock ON If panel lock OFF If code correct If code incorrect FAC 20poInt F ACT OR TYPE 20poInt lInear lInear selected E M E E M E M E M 20poInt selected Continue On Next Page ...

  • Omega DPF500 Series - page 13

    9 4.2 Programming Flowchart (continued) Press the key to step the totalizer decimal to the desired location. Press the E key to enter the displayed decimal location. Press the M key to skip and keep the existing location Press the key to step to the desired totalizer descriptor . Press the E key to enter the displayed descriptor . Press the M key t ...

  • Omega DPF500 Series - page 14

    10 Chapter 5 Operation 5.1 General A suitable pulse producing device or fl ow meter is wired to one of the three pulse inputs provided on the DPF500. Only one of these inputs is used in a given application. There are no connections to the two unused pulse inputs. Isolated magnetic pickups may be connected to terminals 1 and 2. Isolated contact clo ...

  • Omega DPF500 Series - page 15

    1 1 Chapter 6 Error Messages / Analog Output Calibration 6.1 Error Messages The DPF500 is provided with extensive self checking which assists the user in the location of setup entry errors and in reporting malfunctions or unusual operating conditions. When an error occurs, the display will fl ash. Press any key to see the error message correspondi ...

  • Omega DPF500 Series - page 16

    12 Chapter 7 Specifi cations ENVIRONMENT AL: OPERA TING TEMPERA TURE -4°F (-20°C) to + 158°F (70°C) Extended T emp: -22°F (-30°C) to + 158°F (70°C) HUMIDITY 0 - 90% Noncondensing MOUNTING STYLES: 1 - Panel Mount - NEMA 4X Front 2 - W all Mount - NEMA 4X Enclosure (keypad mounted behind clear cover) 3 - Explosion Proof - Class I, Division I ...

  • Omega DPF500 Series - page 17

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s custo ...

  • Omega DPF500 Series - page 18

    M 1896 / 0 7 05 Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OM EGA…Of Course! Shop online at omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, ...

Fabbricante Omega Categoria Calculator

I documenti che otteniamo dal fabbricante del dispositivoOmega DPF500 Series possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Omega
- manuali per l’uso DPF500 Series
- schede prodotto Omega
- opuscoli
- o etichette energetiche Omega DPF500 Series
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Omega DPF500 Series.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Omega DPF500 Series, manuali di manutenzione, brevi manuali o manuali utente Omega DPF500 Series. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Omega DPF500 Series.

Manuali per l’uso simili

Manuale completo del dispositivo Omega DPF500 Series, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Omega DPF500 Series dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Omega DPF500 Series.

Il manuale per l’uso completo Omega, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Omega DPF500 Series - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Omega DPF500 Series, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Omega DPF500 Series che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Omega DPF500 Series - che ci dovrebbe aiutare nei primi passi durante l'uso Omega DPF500 Series
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Omega DPF500 Series
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Omega DPF500 Series in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Omega DPF500 Series?

Utilizza il modulo sottostante

Se non hai risolto il problema con Omega DPF500 Series con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Omega DPF500 Series è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)