Manuale per l’uso Intel SC450NX

24 pagine 0.16 mb
Scarica

Vai alla pagina of 24

Summary
  • Intel SC450NX - page 1

    SC450NX MP Server Rack/Pedestal Kit Installation Guide Order Number: 711917-001a ...

  • Intel SC450NX - page 2

    Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel assumes no responsibility for any errors that may appear in this document. Intel makes no commitment to update nor to keep current the information ...

  • Intel SC450NX - page 3

    Copyright  1998, Intel Corporation. All Rights Reserved. ...

  • Intel SC450NX - page 4

    ...

  • Intel SC450NX - page 5

    v Safety Guidelines Before you remove a server cover, observe these safety guidelines: • Only technically qualified personnel should integrate the server. • Turn off all peripheral devices connected to the server. • Turn off the server using the push-button on/off power switch on the front panel of the server, and unplug the AC power cord fro ...

  • Intel SC450NX - page 6

    vi CAUTIONS E LECTROSTATIC DISCHARGE (ESD) AND ESD PROTECTION : ESD can damage disk drives, add-in boards, and other components. This server can withstand normal levels of environmental ESD while hot -swapping SCSI hard disk drives. However, we recommend doing all procedures in this manual only at an ESD-protected workstation. If one is not availab ...

  • Intel SC450NX - page 7

    vii Equipment Rack Precautions WARNINGS A NCHOR THE EQUIPMENT RACK : The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs). You must also consider the weight of any o ...

  • Intel SC450NX - page 8

    viii ...

  • Intel SC450NX - page 9

    ix Contents Safety Guidelines Server Precautions ............................................................................................................... v Equipment Rack Precautions .............................................................................................. vii Introduction Tools You Need ................................. ...

  • Intel SC450NX - page 10

    x ...

  • Intel SC450NX - page 11

    11 Introduction The SC450NX MP server is designed to either stand upright (pedestal mode) or be mounted in a rack (rack mode). Figures 1 and 2 on page 12 show examples of these configurations. Before operation, you must purchase an adapter kit to configure the server for one of the two modes. If you have already created a pedestal server but now wa ...

  • Intel SC450NX - page 12

    12 Table 1 . SC450NX MP Server Physical Specifications Specification Pedestal Mode Rack Mode Height 48.26 cm (19 inches) 7u Width 31.12cm (12.25 inches) 19 inch rack Depth 63.5cm (25 inches) 25 inches Weight 38.25 kg (85 lbs) minimum configuration 45 kg (100 lbs) maximum configuration 38.25 kg (85 lbs) minimum configuration 45 kg (100 lbs) maximum ...

  • Intel SC450NX - page 13

    13 Configuring for Rack Mount Before starting, please read “ Safety Guidelines ” on page v . Prepare the Slide Assemblies See Figure 3 . 1. Remove the slide assemblies from the kit. 2. Orient a slide assembly so that the smallest outer bar is facing down. 3. Fully extend the telescoping slide assembly until the center bar hits the safety latch ...

  • Intel SC450NX - page 14

    14 Prepare the Server Before you can install the server in the 19-inch equipment rack, you must install a bezel, handles, and the small bars of the slide assemblies onto the sides of the server. Attaching the Bezel Frame and Door To be installed in a rack, the server needs a bezel frame with rectangular cutouts where the chassis handles fit. 1. Att ...

  • Intel SC450NX - page 15

    15 Attach the Small Bar of the Slide Assembly to the Server See Figure 4 . 1. Remove four screws from the kit. 2. While facing the side of the server, orient the small bar so that the flat side faces the top and the right-angle end faces the front of the server. 3. Align the first hole in the right-angle end of the bar with the first threaded hole ...

  • Intel SC450NX - page 16

    16 Prepare the Equipment Rack Before you can install the server in the 19-inch equipment rack, you must attach the center bar and large outer bar assemblies to the vertical rails of the rack. Attach the Right-angle Extension Brackets to the Equipment Rack / NOTE Mounting holes in the vertical rails of equipment racks are commonly spaced in a 5/8 x ...

  • Intel SC450NX - page 17

    17 Attach the Center Bar and Large Outer Bar Assemblies to the Equipment Rack See Figure 6 . 1. Orient a center bar and large outer bar assembly so that the flat side is facing toward the brackets attached to the vertical rails and the safety latch on the center bar is near the back of the rack. 2. Press the flat side of the outer bar into the U -s ...

  • Intel SC450NX - page 18

    18 Install the Server in the Rack WARNINGS A NCHOR THE EQUIPMENT RACK : The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs). You must also consider the weight of an ...

  • Intel SC450NX - page 19

    19 1 Small outer bar 2 Center bar 3 Large outer bar 4 Safety latch Figure 7 . Installing the Server in the Rack ...

  • Intel SC450NX - page 20

    20 ...

  • Intel SC450NX - page 21

    21 Configuring for Pedestal Mount Install Chassis Feet See Figure 8 . 1. Remove two system feet and two screws from the kit. 2. Each system foot has one screw hole and, on the opposite end, two slots that fit two tabs extending from the chassis wall. Orient the chassis foot to align these features with their corresponding parts of the chassis wall. ...

  • Intel SC450NX - page 22

    22 Install Bezel Frame and Door 1. Attach the bezel frame by inserting the tabs at the corner of the frame into their corresponding rectangular slots on the chassis. 2. Attach the bezel door: with the door all the way open (left, as it stands upright in a pedestal mount), align the tabs on the door with their corresponding hinge loops on the chassi ...

  • Intel SC450NX - page 23

    23 Changing from Pedestal to Rack To change your server from pedestal mode to rack mode, you must complete two basic steps: removing the components of the pedestal mount, then configuring the server for a rack mount. Because configuring for a rack mount was described in an earlier section (page 13 ), this section covers only a few details unique to ...

  • Intel SC450NX - page 24

    24 Exchange the Bezel Frame To be installed in a rack, the server needs a new bezel frame with rectangular cutouts where the chassis handles fit. You need to remove the old bezel frame and install the new one from the rack kit. 1. Remove the bezel door: with the door open all the way (to the left), lift it upward to release it from its hinges on th ...

Fabbricante Intel Categoria Life Jacket

I documenti che otteniamo dal fabbricante del dispositivoIntel SC450NX possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Intel
- manuali per l’uso SC450NX
- schede prodotto Intel
- opuscoli
- o etichette energetiche Intel SC450NX
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Intel SC450NX.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Intel SC450NX, manuali di manutenzione, brevi manuali o manuali utente Intel SC450NX. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Intel SC450NX.

Manuali per l’uso simili

Manuale completo del dispositivo Intel SC450NX, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Intel SC450NX dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Intel SC450NX.

Il manuale per l’uso completo Intel, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Intel SC450NX - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Intel SC450NX, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Intel SC450NX che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Intel SC450NX - che ci dovrebbe aiutare nei primi passi durante l'uso Intel SC450NX
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Intel SC450NX
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Intel SC450NX in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Intel SC450NX?

Utilizza il modulo sottostante

Se non hai risolto il problema con Intel SC450NX con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Intel SC450NX è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)