    Page 1 7/2012 506923−01 *2P72012* *P506923-01* E 2012 Lennox Industries Inc. Dallas, T exas, USA THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE W ARNING The S tate of California has determined that this product may contain or produce a chemical or chemicals, in very low doses, which may cause serious illness or death. It may als ...

  • Lennox International Inc. XC21 - page 2

    Page 2 UNIT DIMENSIONS − INCHES (MM) 39−1/2 (1003) 35−1/2 (902) 47 (1 194) 18−1/2 (470) 8 (203) 1 (25) 4−1/2 (1 14) LIQUID LINE INLET ELECTRICAL INLETS SIDE VIEW ACCESS VIEW DISCHARGE AIR 4−5/8 (1 17) BASE WITH ELONGA TED LEGS 16−7/8 (429) 8−3/4 (222) 26−7/8 (683) 3−3/4 (95) 30−3/4 (781) 3−1/8 (79) SUCTIOn LINE INLET UNIT SU ...

  • Lennox International Inc. XC21 - page 3

    Page 3 XC21 SERIES INST ALL UNIT AW A Y FROM WINDOWS TWO 90 _ ELBOWS INST ALLED IN LINE SET WILL REDUCE LINE SET VIBRA TION PLACEMENT FIGURE 2 Install unit level or , if on a slope, maintain slope tolerance of 2 degrees (or 2 inches per 5 feet [50 mm per 1.5 m]) away from building structure. GROUND LEVEL MOUNTING SLAB BUILDING STRUCTURE DISCHARGE A ...

  • Lennox International Inc. XC21 - page 4

    Page 4 IMPORT ANT ! If this unit is being matched with an approved line set or indoor unit coil that was previously charged with mineral oil, or if it is being matched with a coil which was manufactured before January of 1999, th e coil and line set must be flushed prior to inst alla- tion. T ake care to empty all existing trap s. Polyol es- ter (P ...

  • Lennox International Inc. XC21 - page 5

    Page 5 XC21 SERIES STEP 2 −− REFRIGERANT PIPING −− Removing Existing Indoor Metering Device SENSING LINE TEFLON ® RING FIXED ORIFICE BRASS NUT LIQUID LINE ASSEMBL Y (INCLUDES STRAINER) LIQUID LINE ORIFICE HOUSING DISTRIBUT OR TUBES DISTRIBUT OR ASSEMBL Y REMOVE AND DISCARD WHITE TEFLON ® SEAL (IF PRESENT) 1. On fully cased coils, remove t ...

  • Lennox International Inc. XC21 - page 6

    Page 6 STEP 2 −− REFRIGERANT PIPING −− Brazing Procedures A TTACH THE MANIFOLD GAUGE SET FOR BRAZING LIQUID AND SUCTION / V APOR LINE SERVICE V AL VES OUTDOOR UNIT LIQUID LINE SUCTION / V APOR LINE LIQUID LINE SERVICE VA LV E SUCTION / V APOR LINE SER VICE VA LV E A TT ACH GAUGES INDOOR UNIT SUCTION / V APOR SERVICE PORT MUST BE OPEN AND SE ...

  • Lennox International Inc. XC21 - page 7

    Page 7 XC21 SERIES CAUTION Brazing alloys and flux cont ain materials which are hazardous to your health. Avoid breathing vapors or fumes from brazing operations. Perform operations only in well−ventilated areas. Wear gloves and protective goggles or face shield to protect against burns. W as h hands with soap and water af ter handling brazing al ...

  • Lennox International Inc. XC21 - page 8

    Page 8 STEP 3 −− INST ALLING INDOOR EXP ANSION V AL VE This outdoor unit is designed for use in systems that include an exp ansion valve metering device. Se e the XC21 Product Specifications bulletin (EHB) for ap p r o v e d ex p a n s i o n va l v e kit ma t c h − u ps an d ap p l i c a t i o n in f o r m a t i o n . The expansion valve can ...

  • Lennox International Inc. XC21 - page 9

    Page 9 XC21 SERIES STEP 4 −− LEAK TEST AND EV ACUA TION TO V APOR SER VICE V AL VE HFC−410A MANIFOLD GAUGE SET OUTDOOR UNIT HIGH LOW CONNECT GAUGE SET A. Connect the high pressure hose of an HFC−410A manifold gauge set to the vapor valve service port. NOTE  Normally , the high pressure hose is connected to the liquid line port. However , ...

  • Lennox International Inc. XC21 - page 10

    Page 10 STEP 4 −− LEAK TEST AND EV ACUA TION (Continued) A. Open both manifold valves and start the vacuum pum p. B. Evacuate the line set and indoor unit to an absolute pressure of 23,000 microns (29.01 inches of mercury). NOTE  During the early stages of evacuation, it is desirable to close the manifold gauge valve at least once. A rapid r ...

  • Lennox International Inc. XC21 - page 11

    Page 1 1 XC21 SERIES STEP 5 −− ELECTRICAL −− Circuit Sizing and Wire Routing In the U.S .A., wiring must conf orm wit h current local codes and the cur rent National Elec tric Code (NE C). In Canada, wiring m ust confor m with current local codes and t he current Canadian Elec trical Code (CEC) . Refer to the furnace or a ir handler install ...

  • Lennox International Inc. XC21 - page 12

    Page 12 NOTE  For proper voltages, select control wires gauge per table below . WIRE RUN LENGTH A WG# INSULA TION TYPE LESS THAN 100’ (30 METERS) 18 TEMPERA TURE RA TING MORE THAN 100’ (30 METERS) 16 35ºC MINIMUM. NOTE  Wire tie provides low voltage wire strain relief and maintains separation of field−installed low and high voltage cir ...

  • Lennox International Inc. XC21 - page 13

    Page 13 XC21 SERIES STEP 5 −− ELECTRICAL (Continued) −− Out door Control (A175) Jumpers and T erminals 55 50 DEGREE TARGET 45 DEGREE TARGET 40 DEGREE TARGET (DEFAULT) 55 50 45 40 55 50 45 40 55 50 45 40 55 50 45 40 DEGREE TARGET 100 90 DEGREE TARGET 70 DEGREE TARGET 50 DEGREE TARGET 100 90 70 50 DEGREE TARGET 100 90 70 50 100 90 70 50 100 9 ...

  • Lennox International Inc. XC21 - page 14

    Page 14 STEP 5 −− ELECTRICAL (Continued) −− Field Control Wiring Th e following two illustrations provide examples of control wiring connections when using a non−communicating thermostat. For examples of control wiring in complete or p artial communicating systems, see the icomfort t −enabled thermosta t Quick Start Guide which is provi ...

  • Lennox International Inc. XC21 - page 15

    Page 15 XC21 SERIES Y1 O R W1 G D R Y1 L C C B Y2 Y2 W O DS L T T W2 H H O C L Y2 DS DH G R Y1 W2 W1 1 2 4 5 Furnace ComfortSense [ 7000 Thermostats Catalog # Y0349 or Y2081 XC21 T wo − Stage Air Conditioner Control On − board link Low voltage thermostat wiring 3 1. Thermostat T terminals are used for outdoor sensor input. Use for thermostat’ ...

  • Lennox International Inc. XC21 - page 16

    Page 16 Charging The XC21 unit is factory−charged with enough HFC−410A refrigerant to accommodate a 15−foot length of refrigerant piping. Charge should be checked and adjusted using the tables provided on the charging procedure sticker on the unit access panel. Det ailed information is given in the XC21 Inst allation and Service Procedures ma ...

  • Lennox International Inc. XC21 - page 17

    Page 17 XC21 SERIES XC21 Field Operational Checklist Unit Readings Cooling*** Heating*** Y1 First S tage Expected results during Y2 demand (toggle switch ON) Y2 Second S tage Y1 First St age Expected results during Y2 demand (toggle switch ON) Y2 Second S tage Compressor V oltage Same Same Amperage Higher Higher Condenser Fan motor Amperage Same or ...

  • Lennox International Inc. XC21 - page 18

    Page 18 XC21 S tart−Up and Performance Checklist Customer Address Indoor Unit Model Serial Outdoor Unit Model Serial Solar Module Mfg and Model Serial Notes: ST ART−UP CHECKS Refrigerant T ype: Rated Load Amps Actual Amps Rated V olts Actual V olts Condenser Fan Full Load Amps Actual Amps: COOLING MODE V apor Pressure: Liquid Pressure: Supply A ...

  • Lennox International Inc. XC21 - page 19

    Page 19 XC21 SERIES Homeowner Information CAUTION Before attempting to perform any service or mainte- nance, turn the electrical power to unit OFF at discon- nect switch. Cleaning of th e out door unit’s coil should be performed by a licensed professional service technician (or equivalent). Contact your dealer and set up a schedule (preferably tw ...

Fabbricante Lennox International Inc. Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoLennox International Inc. XC21 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Lennox International Inc.
- manuali per l’uso XC21
- schede prodotto Lennox International Inc.
- opuscoli
- o etichette energetiche Lennox International Inc. XC21
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Lennox International Inc. XC21.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Lennox International Inc. XC21, manuali di manutenzione, brevi manuali o manuali utente Lennox International Inc. XC21. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Lennox International Inc. XC21.

Manuale completo del dispositivo Lennox International Inc. XC21, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Lennox International Inc. XC21 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Lennox International Inc. XC21.

Il manuale per l’uso completo Lennox International Inc., dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Lennox International Inc. XC21 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Lennox International Inc. XC21, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Lennox International Inc. XC21 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Lennox International Inc. XC21 - che ci dovrebbe aiutare nei primi passi durante l'uso Lennox International Inc. XC21
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Lennox International Inc. XC21
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Lennox International Inc. XC21 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Lennox International Inc. XC21?

Utilizza il modulo sottostante

Se non hai risolto il problema con Lennox International Inc. XC21 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Lennox International Inc. XC21 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)