Manuale per l’uso Napoleon Fireplaces BGD90NT

32 pagine 4.13 mb
Scarica

Vai alla pagina of 32

Summary
  • Napoleon Fireplaces BGD90NT - page 1

    1 W415-0614 / A / 07.24.07 INSTALLATION AND OPERATION INSTRUCTIONS Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.on.ca INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER . CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ...

  • Napoleon Fireplaces BGD90NT - page 2

    2 W415-0614 / A / 07.24.07 PG2-5 INTRODUCTION W arnings and Safety Precautions W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-9 VENTING V ent lengths V enting Specifi cations Air T erminal Locations 10-14 INST ALLA TION/FRAMING W all & Ceiling Protection Using Flexible V ent Components Fireplac ...

  • Napoleon Fireplaces BGD90NT - page 3

    3 W415-0614 / A / 07.24.07 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON®® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.915. © WOLF STEEL L TD. NAPOLEON® products are manufactured under the strict Standard of the wo ...

  • Napoleon Fireplaces BGD90NT - page 4

    4 W415-0614 / A / 07.24.07 6" Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operat- ing the fireplace. Never obstruct the front opening of the fireplace. Objects placed in fr ont of the fire place must be k ept a minimum of 48” from the fr ont face of the unit. Minimum clearance t ...

  • Napoleon Fireplaces BGD90NT - page 5

    5 W415-0614 / A / 07.24.07 We Suggest that our gas hearth products be installed and serviced by profession- als who are certified in the U.S. by the National Fire- place Institute (NFI) as NFI Gas Specialists. 24" 16" 12" Do not use abrasive cleaners to clean glass. Buff lightly with a clean dry cloth. The glass is 3/16” tempered g ...

  • Napoleon Fireplaces BGD90NT - page 6

    6 W415-0614 / A / 07.24.07 Simple venting confi guration (only one 90° elbow) VERTICAL RISE IN FEET V T FIGURE 4 See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 90° elbow , the following formulas apply: F or mula 1: H T < V T F or mula 2: H T + V T & ...

  • Napoleon Fireplaces BGD90NT - page 7

    7 W415-0614 / A / 07.24.07 H 2 H 1 V 1 90° See graph to determine the required vertical rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .0 3 (t wo 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft H T + V T = 10.7 + 6 =16.7 Formula 1: H T ...

  • Napoleon Fireplaces BGD90NT - page 8

    8 W415-0614 / A / 07.24.07 MAXIMUM VERTICAL RISE IN FEET V T HORIZONT AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than two 90° elbow (top exit) ...

  • Napoleon Fireplaces BGD90NT - page 9

    9 W415-0614 / A / 07.24.07 AIR TERMINAL INST ALLA TIONS * * * * * Recommended to prevent condensation on windows and thermal breakage ** ** ** ** ** It is recommended to use a hea t shield and to maximize the distance to vinyl c lad so ts . *** *** *** *** *** The periscope GD-401 requir es a minimum 18 inc hes cle arance fr om an inside corner ...

  • Napoleon Fireplaces BGD90NT - page 10

    10 W415-0614 / A / 07.24.07 This application occurs when venting through an exterior wall. Having determined the air terminal loca- tion, cut and frame a hole in an exterior wall. The recommended framed opening is 14 1 / 2 ” W x 14 1 / 2 ” H with a minimum 14 1 / 2 ” round or square opening inside a fi nished wall. See fi gure15. 1. Mark an ...

  • Napoleon Fireplaces BGD90NT - page 11

    11 W415-0614 / A / 07.24.07 7. Using the 10” diameter fl exible aluminium liner , apply sealant, slide a minimum of 2” over the fi replace combustion air collar and secure with 6 #8 screws. 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the ve ...

  • Napoleon Fireplaces BGD90NT - page 12

    12 W415-0614 / A / 07.24.07 Pr oceed once the vent installa tion is complete . Note : All gas connections m ust be contained within the fireplace when complete . 1. The fi replace is designed to accept a ½” gas supply line. The fi replace is equipped with a ½” manual shut-off valve, and an 18” listed fl exible gas connector . 2. The acce ...

  • Napoleon Fireplaces BGD90NT - page 13

    13 W415-0614 / A / 07.24.07 WARNING F acing and/or fi nishing material must ne ver o verhang into the fi replace opening. 59 1 /4 " 1" MIN 1" MIN 29" 10" MIN 72" 29" 59 1/4 " 59 1/4 " 29" 59 1/4 " 1 16" 82" FRAMING CLEARANCE T O COMBUSTIBLES MAINT AIN THESE MINIMUM CLEARANCES TO COM ...

  • Napoleon Fireplaces BGD90NT - page 14

    14 W415-0614 / A / 07.24.07 FIGURE 30 MANTLE CLEARANCES 0 34 7 8 9 12 5 6 7 H E I G H T M A N T L E MANTLE WIDTH 5 6 4 3 Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. Do NO T use the fireplace if any part has been under water . Call a qualified service technician IMMEDIA TE ...

  • Napoleon Fireplaces BGD90NT - page 15

    15 W415-0614 / A / 07.24.07 1 . Place the door frame face down careful not to scratch the paint. 2 . Center the gasketed glass inside the door frame with the thick side of the gasket facing up. 3 . Bend the glass retainers located along the edge of the door frame over the gasket holding the glass in place. Careful not to break the glass. LOG SHIPPI ...

  • Napoleon Fireplaces BGD90NT - page 16

    16 W415-0614 / A / 07.24.07 NOTE: Refer to the FINISHING section of the BGD90NT/ PT Installation Manual for instructions on removing the door and log shipping bracket before proceeding. Brick panels are shipped separate from unit due to the brittle material of the bricks, care must be taken not to bend or force them into place. When shipped, the br ...

  • Napoleon Fireplaces BGD90NT - page 17

    17 W415-0614 / A / 07.24.07 6. Place the pin in log #7 in the hole in log #6. The log should sit in the notch on log #2 and the bottom should rest along the right side of the Andiron. 7. Place the large end of log#8 into the rear notch of log#4. The small branch of log#8 sits in the notch located on top of log#1. 8 PHAZER™ logs and glowing embers ...

  • Napoleon Fireplaces BGD90NT - page 18

    18 W415-0614 / A / 07.24.07 GLO WING EMBERS CHARCO AL EMBERS Randomly place the charcoal embers along the front and sides of the Hearth Panels in a realistic manner . Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers. Note: Both charcoal embers and vermiculite are not to be placed on the bu ...

  • Napoleon Fireplaces BGD90NT - page 19

    19 W415-0614 / A / 07.24.07 RECEIVER SLO T SP ARK MODULE VA LV E WING NUT 1. Remove access panel from inside the fi rebox. 2. Unplug the control module from the junction box 3. Pull up on the control module being held down with velcro and disconnect the plugs (fan, aux). Remove wiring harness from the front of casing. 4. Install the new control mo ...

  • Napoleon Fireplaces BGD90NT - page 20

    20 W415-0614 / A / 07.24.07 T o operate this fi replace using the remote, the pilot must be running and the gas valve turned to the “ON” position. Ensure that the receiver has power and the backup switch is in the auto position. 1. Install the batteries (AAA) into the remote control transmitter . The “HOUSE” icon with room temperature will ...

  • Napoleon Fireplaces BGD90NT - page 21

    21 W415-0614 / A / 07.24.07 5. F AN SPEED SETTING This function controls the speed of the hot air circulating fan. T o change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6. TIMER SETTING The Remote Control has a sleep fu ...

  • Napoleon Fireplaces BGD90NT - page 22

    22 W415-0614 / A / 07.24.07 ADDRESS SETTING PROCEDURE Use the UP and DOWN key on the transmitter until the cursor (small triangle) is left of the clock icon. From time 0:00 press the LEFT key ten times. The display will show then the trans- mitter address. Press the LEFT key to exit this function. The transmitter address is required to be equal to ...

  • Napoleon Fireplaces BGD90NT - page 23

    23 W415-0614 / A / 07.24.07 DIP SWIT CH NUMBER (0 = ON / 1 = OFF) ...

  • Napoleon Fireplaces BGD90NT - page 24

    24 W415-0614 / A / 07.24.07 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor . C. Use only your hand to turn the gas control ...

  • Napoleon Fireplaces BGD90NT - page 25

    25 W415-0614 / A / 07.24.07 ADJUSTMENTS TURN OFF THE G AS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPL ACE. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. V erify proper operation after ser- vicing. This fi replace and its venting system should be inspected bef ...

  • Napoleon Fireplaces BGD90NT - page 26

    26 W415-0614 / A / 07.24.07 PILOT BURNER THERMOCOUPLE THERMOPILE FLAME MUST ENVELOP UPPER 3/8” T O 1/2” OF THERMOCOUPLE & THERMOPILE Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may ...

  • Napoleon Fireplaces BGD90NT - page 27

    27 W415-0614 / A / 07.24.07 # P ART NO. DESCRIPTION 1* W390-0002 DOOR LA TCH ( EA ) 2 W725-0047 NA TURAL GAS V AL VE - MODULA TING 2 W725-0048 PROP ANE GAS VAL VE - MODULATING 3 W455-0040 #41 NA TURAL GAS ORIFICE 3 W455-0058 #35 NA TURAL GAS ORFICE 3 W455-0059 #53 PROP ANE GAS ORIFICE 4 W680-0014 THERMOCOUPLE 5 W240-0008 ELECTRODE C / W LEAD 6 W680 ...

  • Napoleon Fireplaces BGD90NT - page 28

    28 W415-0614 / A / 07.24.07 6 4 8 7 5 40 22 27 28 29 30 34 26 25 33 61 32 61 31 11 62 20 2 14 15 12 3 13 18 16 68 52 55 21 76 43 66 67 AUX ON 0:00 00 ON/OFF FEATURE SELECT * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting ther- mocouple supplied by Wolf Steel Ltd. ...

  • Napoleon Fireplaces BGD90NT - page 29

    29 W415-0614 / A / 07.24.07 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become per- manently marked. Carbon is being de- posited on glass, ...

  • Napoleon Fireplaces BGD90NT - page 30

    30 W415-0614 / A / 07.24.07 Main burner goes out; pilot goes out. Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo- pile - turn up pilot fl ame. - replace pilot assembly . Thermopile shorting - clean thermopile connection to the valve. Reconnect. - test and replace thermopile if required. T empe ...

  • Napoleon Fireplaces BGD90NT - page 31

    31 W415-0614 / A / 07.24.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SER VICE PERFORMANCE SPECIAL CONCERNS ...

  • Napoleon Fireplaces BGD90NT - page 32

    32 W415-0614 / A / 07.24.07 NO TES ...

Fabbricante Napoleon Fireplaces Categoria Indoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoNapoleon Fireplaces BGD90NT possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Napoleon Fireplaces
- manuali per l’uso BGD90NT
- schede prodotto Napoleon Fireplaces
- opuscoli
- o etichette energetiche Napoleon Fireplaces BGD90NT
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Napoleon Fireplaces BGD90NT.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Napoleon Fireplaces BGD90NT, manuali di manutenzione, brevi manuali o manuali utente Napoleon Fireplaces BGD90NT. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Napoleon Fireplaces BGD90NT.

Manuale completo del dispositivo Napoleon Fireplaces BGD90NT, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Napoleon Fireplaces BGD90NT dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Napoleon Fireplaces BGD90NT.

Il manuale per l’uso completo Napoleon Fireplaces, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Napoleon Fireplaces BGD90NT - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Napoleon Fireplaces BGD90NT, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Napoleon Fireplaces BGD90NT che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Napoleon Fireplaces BGD90NT - che ci dovrebbe aiutare nei primi passi durante l'uso Napoleon Fireplaces BGD90NT
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Napoleon Fireplaces BGD90NT
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Napoleon Fireplaces BGD90NT in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Napoleon Fireplaces BGD90NT?

Utilizza il modulo sottostante

Se non hai risolto il problema con Napoleon Fireplaces BGD90NT con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Napoleon Fireplaces BGD90NT è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)