  • Friedrich SV08 - page 1

    Room Air Conditioner Ser vice and P ar ts Man ual Slider Casement SV08 / SV10 / SV12 (01/05) 115V olts • SV08A10A • SV10A10A • SV12A10A High Cool Med Fan Off Mode Temperature Med Cool Low Cool Low Fan Cooler Warmer ...

  • Friedrich SV08 - page 2

    —2— 1. PREF A CE 1.1 SAFETY PRECAUTIONS ................................2 1.2 INSULATION RESISTANCE TEST .................2 1.3 SPECIFICATIONS ...........................................3 1.4 FEATURES......................................................4 1.5 CONTROL LOCATIONS .................................4 2. DISASSEMBL Y INSTR UCTIONS 2.1 ...

  • Friedrich SV08 - page 3

    —3— POWER SUPPLY COOLING CAPACITY (Btu/h) INPUT (W) RUNNING CURRENT (A) E.E.R (BTU/W . h) INDOOR (°C) OUTDOOR (°C) REFRIGERANT (R-22) CHARGE EVAPORATOR CONDENSER FAN, INDOOR FAN, OUTDOOR FAN SPEEDS, FAN/COOLING FAN MOTOR OPERATION CONTROL ROOM TEMP. CONTROL AIR DIRECTION CONTROL CONSTRUCTION PROTECTOR COMPRESSOR FAN MOTOR POWER CORD DRAIN SYS ...

  • Friedrich SV08 - page 4

    —4— 1.4 FEA TURES • Designed for COOLING ONLY. • Powerful and whispering cooling. • Simple installation and service. • Low air-intake, top cooled-air discharge. 1.5 CONTR OL LOCA TIONS 1.5.1 COOLING ONL Y MODEL • VENTILATION The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fres ...

  • Friedrich SV08 - page 5

    — 5 — 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Open the inlet grille downward and remove the air filter. 2. Remove the screws which fasten the front grille.(See Figure 1) 3. Pull the front grille from the right side. 4. Remove the front grille.(There are 4 hooks.) 5. Re-install the components by referring to the removal procedure, above. 2. ...

  • Friedrich SV08 - page 6

    — 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE AND TURBO F AN 1. Remove the front grille. (Refer to section 2.1.1) 2. Remove the cabinet. (Refer to section 2.1.2) 3. Remove the control box. (Refer to section 2.1.3) 4. Remove the 4 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the upper air guide. (See F ...

  • Friedrich SV08 - page 7

    — 7 — 2.2.3 SHROUD 1. Remove the fan. (Refer to section 2.2.2) 2. Remove the shroud. (See Figure 8) 3. Re-install the components by referring to the removal procedure, above. 2.3 ELECTRICAL P AR TS 2.3.1 O VERLO AD PRO TECT OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the nut which fastens the terminal cover. 3. Remove the termi ...

  • Friedrich SV08 - page 8

    — 8 — 2.3.3 CAP A CIT OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the screw and the clamp which fasten the capacitor. 3. Disconnect all the leads of capacitor terminals. 4. Re-install the components by referring to the removal procedure, above. (See Figure 11) 2.3.4 PO WER CORD 1. Remove the cabinet. (Refer to section 2.1.2) 2. ...

  • Friedrich SV08 - page 9

    — 9 — 2.3.7 MO T OR 1. Remove the cabinet. (Refer to section 2.1.2) 2. Remove the turbo fan. (Refer to section 2.2.1) 3. Remove the fan. (Refer to section 2.2.2) 4. Remove the 4 screws which fasten the motor from the Motor Mount. (See Figure 15) 5. Remove the motor. 6. Re-install the components by referring to the removal procedure, above.(See ...

  • Friedrich SV08 - page 10

    — 10 — — Replacement of the refrigerant. 1. When replacing the refrigerant, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system to, install one (such as a WATCO A-1) before venting the Freon TM . Leave the valve in place after servicing the system. 2. After dischargi ...

  • Friedrich SV08 - page 11

    — 11 — Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve. A COMPOUND GAUGE EVAPORATOR (LOW PRESSURE SIDE) COMPRESSOR CAPILLARY TUBE CONDENSER (HIGH PRESSURE SIDE) SEE INSETS BELOW M ...

  • Friedrich SV08 - page 12

    — 12 — 3. INST ALLA TION 3.1 HO W T O INST ALL THE UNIT 1. To avoid vibration and noise, make sure the unit is installed securely and firmly. 2. Install the unit where the sunlight does not shine directly on the unit. If the unit receives direct sunlight, build an awning to shade the cabinet. 3. There should be no obstacle, like a fence, within ...

  • Friedrich SV08 - page 13

    — 13 — 3.4 WINDO W REQUIREMENTS 1. These instructions are for a horizontal sliding or a casement window. 2. The electrical outlet must be within reach of the power cord. For installation in a casement window, the window frame assembly and the side of the building must be adequate to support the weight of the air conditioner. 3.5 INST ALLA TION ...

  • Friedrich SV08 - page 14

    — 14 — 1. Loosely attach the support bracket to the bottom of bracket using bolts, washers, and nuts. Attach the leveling bolt and nut. (See Figure 22) 2. Remove protective backing from window track seal and apply seal to window track. (See Figure 23) 3. Measure and lightly mark a line 8-1/4" from window jamb. Center the support bracket as ...

  • Friedrich SV08 - page 15

    — 15 — 8. Slide curtain into curtain frame. Slide curtain frame assembly into side guides of the air conditioner cabinet. Make sure curtain is firmly enclosed on all sides by the frame. (See Figure 27) 9. Cut side guide seal into 2 equal lengths. Remove protective backing and apply it to the rear side of cabinet side guides, starting just below ...

  • Friedrich SV08 - page 16

    — 16 — 4. TR OUBLESHOO TING GUIDE 4.1 OUTSIDE DIMENSIONS 368(14 1 / 2 ) 521(20 1 / 2 ) 607(23 3 / 5 ) CAPILLARY TUBE COMPRESSOR TURBO F AN EV APORA TOR COIL CONDENSER COIL FA N MOTOR 4.2 PIPING SYSTEM Following is a brief description of the important components and their functions in the refrigeration system. Refer to Fig. 31 to follow the refr ...

  • Friedrich SV08 - page 17

    — 17 — 4.3 TR OUBLESHOO TING GUIDE In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and/or improper application. Unit runs but poor cooling. Ineffective Cooling Check ...

  • Friedrich SV08 - page 18

    — 18 — Fails to Start Check circuit break er and fuse. Gas leakage of f eeler bulb of ther mostat Check control s witch. F an only fails to start. Improper wiring. Def ectiv e of f an motor capacitor . Irregular motor resistance ( ). Irregular motor insulation ( ). Replacement of f an motor . T ests nor mal but f ails to star t. Replacement of ...

  • Friedrich SV08 - page 19

    — 19 — COMPLAINT CAUSE REMEDY Check voltage at outlet. Correct if none. Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Check switch continuity. Refer to wiring diagram for terminal identification. Replace switch if defective. Connect wire. Refer to wiring diagram for terminal identification. R ...

  • Friedrich SV08 - page 20

    — 20 — COMPLAINT CAUSE REMEDY Check the position of knob If not at the coldest setting, advance the knob to this setting and restart unit. Check continuity of the thermostat. Replace thermostat if circuit is open. Check the capacitor. Replace if not within ±10% of manufacturers rating. Replace if shorted, open, or damaged. Check the compressor ...

  • Friedrich SV08 - page 21

    5. SCHEMA TIC DIA GRAM 5.1 CIRCUIT DIA GRAM ■ MODEL : SV10A10A / SV1210A — 21 — SV10A10A SV12A10A PART NO. 1 POWER CORD - - 1 S 2 ROTARY SWITCH 67300501 1 S 3 FAN MOTOR 67303015 1 S 4 CAPACITOR 67300709 - 1 S 5 THERMOSTAT 67300403 1 S 6 COMPRESSOR 67301614 67301615 1 S LOCATION NO. DESCRIPTION RE- MARKS Q'TY PER SET S: Service Parts N: N ...

  • Friedrich SV08 - page 22

    — 22 — 5.2 CIRCUIT DIA GRAM ■ MODEL : SV08A10A SV08A10A PART NO. 1 POWER CORD 67300005 1 S 2 ROTARY SWITCH 67300501 1 S 3 FAN MOTOR 67303014 1 S 4 CAPACITOR 67300712 1 S 5 THERMOSTAT 67300403 1 S 6 COMPRESSOR 67301612 1 S LOCATION NO. DESCRIPTION RE- MARKS Q'TY PER SET S: Service Parts N: Non Service Parts ...

  • Friedrich SV08 - page 23

    6. EXPLODED VIEW — 23 — 554030 148000 352390-2 349001 349600 346811 354210 152312 147581 145200 147582-2 135312 147582-1 135301 264110 269310 266003 249950 130910 359011 130410 552111 352113 352390-1 149980 W0CZZ 567502 554160 550140 349480 135303 359012 352115 35211A 149410 H i g h C o o l M e d F a n O f f M o d e M e d C o o l L o w C o o l ...

  • Friedrich SV08 - page 24

    — 24 — 7. REPLA CEMENT P AR TS LIST ■ MODEL : SV08A10A, SV10A10A, SV12A10A P/No SV08A10A SV10A10A SV12A10A 130410 BASE ASSEMBLY, SINGLE 67302911 67302910 R 130910 CABINET ASSEMBLY, SINGLE 67303706 R 135303 GRILLE INLET 67306105 R 135312 GRILLE ASSEMBLY, FRONT 67306007 R 147581 VANE, HORIZONTAL 67306204 R 147582 VANE, VERTICAL 67306254 6730625 ...

  • Friedrich SV08 - page 25

    — 25 — MEMO ...

  • Friedrich SV08 - page 26

    — 26 — MEMO ...

  • Friedrich SV08 - page 27

    Printed in the U.S.A Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4480 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com P/NO.: 3828A20190X SV08 / SV10 / SV12 (01/05) Use F actor y Cer tified P ar ts... ...

Fabbricante Friedrich Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoFriedrich SV08 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Friedrich
- manuali per l’uso SV08
- schede prodotto Friedrich
- opuscoli
- o etichette energetiche Friedrich SV08
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Friedrich SV08.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Friedrich SV08, manuali di manutenzione, brevi manuali o manuali utente Friedrich SV08. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Friedrich SV08.

Manuali per l’uso simili

Manuale completo del dispositivo Friedrich SV08, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Friedrich SV08 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Friedrich SV08.

Il manuale per l’uso completo Friedrich, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Friedrich SV08 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Friedrich SV08, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Friedrich SV08 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Friedrich SV08 - che ci dovrebbe aiutare nei primi passi durante l'uso Friedrich SV08
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Friedrich SV08
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Friedrich SV08 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Friedrich SV08?

Utilizza il modulo sottostante

Se non hai risolto il problema con Friedrich SV08 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Friedrich SV08 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)