Manuale per l’uso Fluke PN 3612805

22 pagine 1.11 mb
Scarica

Vai alla pagina of 22

Summary
  • Fluke PN 3612805 - page 1

    PN 3612805 July 2010 © 2010 Fluke Corp oration. All ri ghts reserved. Pr inted in Taiwan. S pecifications are subject to chang e without no tice. All product nam es are trademarks o f their respecti ve companies. 373 Clamp Meter Users Manual ...

  • Fluke PN 3612805 - page 2

    LIMITED WARRANTY A ND LIMITATION OF LIA BILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchas e. This warrant y does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alter ation, contamination, or abnormal conditions of operation or ha ndlin g. Resell ...

  • Fluke PN 3612805 - page 3

    i Table of Contents Title Page Introduction ................................................................................................................. 1 How to Contact Fluke ................................................................................................. 1 Safety Information .................................................. ...

  • Fluke PN 3612805 - page 4

    373 Users Manual ii ...

  • Fluke PN 3612805 - page 5

    1 Introduction XW Warning Read "Safety Information" before you use the Meter. The Fluke 373 Clamp Meter (the Meter) measures true-rms ac and dc voltage, ac current, resistance, and capacitance. How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-4 43-5853) ? ...

  • Fluke PN 3612805 - page 6

    373 Users Manual 2 Or, visit Fluke's website at www.fluke.com . To register your product, visit http://register.fluke.com . To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals . Safety Information A Warning identifies conditions and actions t hat pose hazard(s) to the user; A Caution identifi ...

  • Fluke PN 3612805 - page 7

    Clamp Meter Safety Information 3 • Remove the test leads from the Meter before th e battery door is opened. • Examine the test leads for damaged insulation o r exposed metal. Check test lead continuity. Repl ace damaged test leads be fore using the Meter. • Do not use the Meter if it o perates incorrectly. Protecti on can be compr omised. Whe ...

  • Fluke PN 3612805 - page 8

    373 Users Manual 4 • Connect the common t est lead before co nnecting the li ve test lead. When disconnecting test lea ds, disconnect the li ve test lead first. • Do not work alone so assista nce can be rendered in a n emergency. • Use extreme caution w hen working aroun d bare conductors or bus bars. Contact with the conduc tor could result ...

  • Fluke PN 3612805 - page 9

    Clamp Meter Safety Information 5 Table 1. Symbols Symbol Meaning S ymbol Meaning B AC (Alternating Current) J Earth ground F DC (Direct Current) ~ Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information. X Hazardous voltage P Conforms to European Union directives. W Risk of Danger. Important inf ...

  • Fluke PN 3612805 - page 10

    373 Users Manual 6 Symbol Meaning S ymbol Meaning CAT III IEC Measurement Category III CAT III equipment has protection against transients in equipment in fixed-equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. CAT IV IEC Measurement Category IV CAT IV equipment has pro ...

  • Fluke PN 3612805 - page 11

    Clamp Meter The Meter 7 The Meter 1 ghl008.eps ...

  • Fluke PN 3612805 - page 12

    373 Users Manual 8 Auto Off 20 ghl001.eps ...

  • Fluke PN 3612805 - page 13

    Clamp Meter The Meter 9 Backlight ghl002.eps ...

  • Fluke PN 3612805 - page 14

    373 Users Manual 10 A ghl003.eps ...

  • Fluke PN 3612805 - page 15

    Clamp Meter The Meter 11 V V V V or > 30 V ghl004.eps ...

  • Fluke PN 3612805 - page 16

    373 Users Manual 12 < 30 ghl005.eps ...

  • Fluke PN 3612805 - page 17

    Clamp Meter The Meter 13 CAT III 600 V CAT I V 300 V 1 3 2 HOLD HOLD ghl006.eps ...

  • Fluke PN 3612805 - page 18

    373 Users Manual 14 1 2 3 ghl007.eps ...

  • Fluke PN 3612805 - page 19

    Clamp Meter The Meter 15 Electrical Specifications AC Current Range ..................................................... 600.0 A Resolution ............................................... 0.1 A Accuracy ................................................. 2 % ± 5 digits (48 – 62 Hz) Crest Factor (50/60 Hz) .......................... 2.5 @ 600 A AC ...

  • Fluke PN 3612805 - page 20

    373 Users Manual 16 Accuracy ................................................. 1 % ± 5 digits Continuity Beeper ................................... ≤ 30 Ω Capacitance Range ..................................................... 10.0 – 100.0 μ F / 1000 μ F Resolution ............................................... 0.1 μ F/1 μ F Accuracy ... ...

  • Fluke PN 3612805 - page 21

    Clamp Meter The Meter 17 Operating Altitude ................................... 3000 meters Storage Altitude ...................................... 12,000 meters EMI, EMC ................................................ Meets all applicable requirements in EN61326-1:2 006 Temperature Coefficients ........................ Add 0.1 x spec ified accura ...

  • Fluke PN 3612805 - page 22

    373 Users Manual 18 ...

Fabbricante Fluke Categoria Thermometer

I documenti che otteniamo dal fabbricante del dispositivoFluke PN 3612805 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Fluke
- manuali per l’uso PN 3612805
- schede prodotto Fluke
- opuscoli
- o etichette energetiche Fluke PN 3612805
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Fluke PN 3612805.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Fluke PN 3612805, manuali di manutenzione, brevi manuali o manuali utente Fluke PN 3612805. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Fluke PN 3612805.

Manuali per l’uso simili

Manuale completo del dispositivo Fluke PN 3612805, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Fluke PN 3612805 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Fluke PN 3612805.

Il manuale per l’uso completo Fluke, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Fluke PN 3612805 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Fluke PN 3612805, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Fluke PN 3612805 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Fluke PN 3612805 - che ci dovrebbe aiutare nei primi passi durante l'uso Fluke PN 3612805
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Fluke PN 3612805
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Fluke PN 3612805 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Fluke PN 3612805?

Utilizza il modulo sottostante

Se non hai risolto il problema con Fluke PN 3612805 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Fluke PN 3612805 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)