Manuale per l’uso Sharp IG-A10EK

24 pagine 2.94 mb
Scarica

Vai alla pagina of 24

Summary
  • Sharp IG-A10EK - page 1

    日本語 ENGLISH プラズマクラスターイオン発生機 取扱説明書   この取扱説明書をよくお読みのうえ、 正しくお使いください。 Please read this manual and keep it somewhere safe. IG-A10EK Plasmacluster is a trademarks of SHA RP Corporation. Plasmacluster Ion Generator OPERA TION MANUAL IG-A10EK.Jpn_Eng.i ...

  • Sharp IG-A10EK - page 2

    FEA TURES SHARP’ s Original Air Disinfecting T echnology . Plasmacluster HD helps to improve the air quality by eliminating of airborne mold *1 , viruses *2 , allergens *3 , and abhering odor *4 . Release Plasmacluster Ions. 1 Plasmacluster Ions are the same positive and negative i o n s f o u n d i n n a t u r e . T h e ions are surrounded by wa ...

  • Sharp IG-A10EK - page 3

    日本語 ENGLISH Hydroxide (OH) radical J-1 日本語 お買 い あげ い ただ き 、ま こ とに あ りが と うご ざ い まし た 。 この 取 扱説 明 書を よ くお 読 みの う え、 正 しく お 使 いく だ さい 。 ご使 用 の前 に 、「 安 全上 の ご注 意 」 を必 ず お読 み く ださ い ...

  • Sharp IG-A10EK - page 4

    J-2 安全上のご注意 必ずお守りください。 警 告 : 火災や感電、けがを防ぐ • ご使用前にお読みください。 お使いになる人や他の人への危害、財産への損害を防止するため 、お守りいた だくことを説明しています。 ■表示を無視して、誤った取り扱いをす? ...

  • Sharp IG-A10EK - page 5

    日本語 ENGLISH J-3 表示部 背面 ルーバー 電源コード 差込プラグ 風量 「強」 ランプ (青) ユニット交換ランプ (赤) 各部のなまえ プラズマクラスターイオン発生ユニット交換時 に使用します。 それ以外のときは押さないでください。 (J-4 ページ ) トップカバー キ ...

  • Sharp IG-A10EK - page 6

    J-4 プラズマクラスターイオン発生機の近くでは 、 シリコーンを配合した化粧品などは使わない。 シリコーン配合商品には、次のようなものが あります。 スプレー ワックス 殺虫剤 静電気防止剤、防水スプレー、つや出し剤 ガラスクリーナー、化学ぞうきん? ...

  • Sharp IG-A10EK - page 7

    日本語 ENGLISH J-5 お手入れ お手入れのときは必ず差込プラグをコンセントから抜いてください。 ( 感電やけがの原因 ) Every month or more often if necessary 本 体 1 カ月に 1 回程度 . < 汚れが落ちにくいとき > 台所用合成洗剤を薄めた液に浸した布を固 くしぼって、 ...

  • Sharp IG-A10EK - page 8

    J-6 この商品は安定して高濃度プラズマクラスターイオンを放出するために、 定期的にプラズマクラスターユニットを交換していただく必要があります。 交換時期をユニット交換ランプでお知らせしますので、 交換してください。 経過時間 プラズマクラスタ? ...

  • Sharp IG-A10EK - page 9

    日本語 ENGLISH J-7 交換方法 ※プラズマクラスターイオン発生ユニットの交換時、差込プラグをコンセント から抜いてください。その際、濡れた手で触らないでください 。 1 ルーバーをはずす トップカバー キャップをはずす 2 2 つのネジをはずす ネジ 4 5 トップ ...

  • Sharp IG-A10EK - page 10

    J-8 仕 様 故障かな? ( こんなときは ) ※この商品を壁際の台の上に置いて、 風量「強」運転時に部屋中央付近 ( 床上から高さ 1.2m) の地点で、 空中に吹き出されるイオン個数が約 25,000 個 /cm 3 測定できる部屋の広さの目安です。 形 名 電 源 消費電力 (W) 定? ...

  • Sharp IG-A10EK - page 11

    日本語 ENGLISH IG-A10EK.Jpn_Eng.indd 11 09.10.9 10:03:31 AM ...

  • Sharp IG-A10EK - page 12

    IG-A10EK.Jpn_Eng.indd 12 09.10.9 10:03:31 AM ...

  • Sharp IG-A10EK - page 13

    日本語 ENGLISH ENGLISH Th a nk you for pur ch a si n g th is S H AR P Plasmacluster Ion Generator . Please read this manual carefully before using Plasmacluster Ion Generator . Af t er re a di n g, keep the m an u al i n a c o nv e ni e nt lo c at i o n f or fu t ur e r e fe r en c e. E-1 CONTENTS IMPORT ANT SAFETY INSTRUCTIONS ............... E ...

  • Sharp IG-A10EK - page 14

    E-2 IMPORT ANT SAFETY INSTRUCTIONS CAUTIONS CONCERNING OPERA TION: • DO NOT block the air intake and/or air outlet. • DO NOT use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam. • Always operate the main unit in an upright position. • Clean the exterior with a soft cloth only , otherwi ...

  • Sharp IG-A10EK - page 15

    日本語 ENGLISH E-3 FRONT BACK Louvers P ARTS NAME (See E-4) T op Cover Cap Screws Air outlet T op Cover Plasmacluster Ion Generating Unit (See E-6,7) Filter (Air Intake) (See E-5) Power Cord Plug Use a pointed object, e.g a pen tip, to press this button after replacing Plasmacluster Ion Generating Unit. Do not press it for any other purpose. (Th ...

  • Sharp IG-A10EK - page 16

    E-4 INST ALLA TION POSITION Place the main unit on a smooth, stable surface in a room and insert the plug into an outlet. DO NOT hold the louvers when carrying the unit. Leave at least 15cm of clearance behind the Unit. UPSIDE More than 1m Installation Guidance. BACKSIDE More than 15cm LEFT/RIGHT SIDE More than 20cm DO NOT USE the below items near ...

  • Sharp IG-A10EK - page 17

    日本語 ENGLISH E-5 CLEANING AND MA INTENANCE W ARNING: When cleaning the unit, be sure to unplug the power cord rst, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result. Main Unit Every month or more often if necessary Wipe with a dry soft cloth. <For Stubborn Dirt> rt> Use water and ...

  • Sharp IG-A10EK - page 18

    E-6 PLASMACLUSTER ION GENERA TING UNIT REPLACEMEN T T o ensure the efficacy of the Plasmacluster Ion Generator it is necessary to periodically replace the Ion Generating unit. The unit light will turn on to indicate when replacement is required. Elapsed T ime Plasmacluster Ion Generating Unit for replacement Display Message *Usage environment affec ...

  • Sharp IG-A10EK - page 19

    日本語 ENGLISH E-7 PLASMACLUSTER ION GENERA TING UNIT REPLACEMEN T HO W T O RE PL A CE T H E PL A SM A CL US T ER ION GENERA TING UNIT *When replacing the Plasmacluster Ion Generating Unit, be sure to turn off the main unit, unplug the power cord, and never handle the plug with wet hands. 1 Remove the LOUVERS. Remove the TOP COVER CAP . 2 T urn ...

  • Sharp IG-A10EK - page 20

    E-8 SPECIFICA TIONS TROUBLESHOOTING *The target oor surface area, for which an emitted airborne ion density is of about 25,000 ions/cm 3 , can be mea sured at a poi nt near the c enter of the r oom (at a he ight of about 1.2 m from t he oor ), during operation at the HIGH mode when the main unit is placed near a wall. • The number of ions w ...

  • Sharp IG-A10EK - page 21

    日本語 ENGLISH A. Information on Disposal for Users (pri vate households) 1. In the European Union Attention: If you want to di spose of this equipment, please do not use the ordinary dust bin! Used electrical and electro nic equipment must be trea ted separately and in accordance with legislation that requi res proper treatmen t, recovery and r ...

  • Sharp IG-A10EK - page 22

    GUARANTEE Sharp Elec tronics (UK) Ltd. (“S harp”) guarantee s that for a period of 1 ye ar from the date of purchase the enclosed product will be free from defects in materials and workmanship. Sharp agrees to provide for the repair or , at its option, the replacement of a defective product. Sharp reser ves the right to replace defective par ts ...

  • Sharp IG-A10EK - page 23

    日本語 ENGLISH GUARANTEE Sharp Elec tronics (UK) Ltd. (“S harp”) guarantee s that for a period of 1 ye ar from the date of purchase the enclosed product will be free from defects in materials and workmanship. Sharp agrees to provide for the repair or , at its option, the replacement of a defective product. Sharp reser ves the right to replac ...

  • Sharp IG-A10EK - page 24

    Printed in China TINS-A358KKRZ 09J- 1 CN SHARP ELECTRONICS (U.K.) Ltd 4 Furzeground Way, Stockley Park, Uxbridge, Middlesex, UB11 1EZ. London, U.K. U.K. : 08705 274277 (office hours) Ireland : 01 676 0648 (office hours) Website : http://www.sharp.co.uk/support IG-A10EK.Jpn_Eng.indd 24 09.10.9 10:03:39 AM ...

Fabbricante Sharp Categoria Air Cleaner

I documenti che otteniamo dal fabbricante del dispositivoSharp IG-A10EK possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Sharp
- manuali per l’uso IG-A10EK
- schede prodotto Sharp
- opuscoli
- o etichette energetiche Sharp IG-A10EK
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Sharp IG-A10EK.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Sharp IG-A10EK, manuali di manutenzione, brevi manuali o manuali utente Sharp IG-A10EK. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Sharp IG-A10EK.

Manuali per l’uso simili

Manuale completo del dispositivo Sharp IG-A10EK, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Sharp IG-A10EK dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Sharp IG-A10EK.

Il manuale per l’uso completo Sharp, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Sharp IG-A10EK - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Sharp IG-A10EK, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Sharp IG-A10EK che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Sharp IG-A10EK - che ci dovrebbe aiutare nei primi passi durante l'uso Sharp IG-A10EK
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Sharp IG-A10EK
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Sharp IG-A10EK in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Sharp IG-A10EK?

Utilizza il modulo sottostante

Se non hai risolto il problema con Sharp IG-A10EK con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Sharp IG-A10EK è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)