    RuggedCo m Inc. I 30 Whitmore Road, Woodbridg e, Ontario, C anada L4L 7Z4 Tel: (905) 85 6-5288 I Fax: (905) 856-19 95 I Tol l Free: (888) 26 4-0006 Rugged Rugged Rugged Rugged VDSL VDSL VDSL VDSL     R S9 RS9 RS9 RS9 1 1 1 1 0 0 0 0L L L L Serial and Ether net Device Serv er with Ethernet o ver VDSL Uplink Installation Gui de www.rugged ...

  • RuggedCom RS910L - page 2

    2  2007 RuggedCo m Inc. All rights re served Rev100 Federal Communicati ons Commission Radio Frequency Inter ference Statem ent This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to p rovide reason able protection against harmful interfer ...

  • RuggedCom RS910L - page 3

    3  2007 RuggedCo m Inc. All rights re served Rev100 Table of Contents 1 Product Overview ............................................................................................................................... 5 1.1 Functional Overview ........................................................................................................ ...

  • RuggedCom RS910L - page 4

    4  2007 RuggedCo m Inc. All rights re served Rev100 Table of Figures Figure 1 - RS910L Front Pa nel Descrip tion ............................................................................................... 6 Figure 2 - RS910L Bottom Panel Description ............................................................................................ ...

  • RuggedCom RS910L - page 5

    5  2007 RuggedCo m Inc. All rights re served Rev100 1 Product O verview 1.1 Functional Ove rview The Rugged VDSL TM RS910L is a n indu strial hardened serial server and man aged Ethernet switch supporting Ethernet over VDSL (EoVDSL). The RS910L can be configured with 2 serial ports (RS485/RS422/RS232/fiber) and/or 2 Ethernet ports (copper o r fi ...

  • RuggedCom RS910L - page 6

    6  2007 RuggedCo m Inc. All rights re served Rev100 1.3 RS910L Front Pan el Description Failsafe Relay Power Port Ports 1 & 2 RS485/422/232 Serial Or Serial over Fiber Ports 3 & 4 10/100Base-TX or 100Base-FX Or 10Base-FL Port 9 Ethernet over VDSL Power & Alarm Figure 1 - RS910L Front Panel Descript ion Status LED Colour Activity Comm ...

  • RuggedCom RS910L - page 7

    7  2007 RuggedCo m Inc. All rights re served Rev100 1.4 RS910L Bottom P anel Description Failsafe Relay Console Port Power Port Chassis Ground Optional Din-Ra il Mounting Brack et Figure 2 - RS910L Bottom Panel Description ...

  • RuggedCom RS910L - page 8

    8  2007 RuggedCo m Inc. All rights re served Rev100 2 Inst allation 2.1 Din Rail Mounting An optional DIN rail mounting bracket is available for the RS910L. The figure below details mounting instructions for the standard 1” DIN Rail. Figure 3 - RS910L DIN Rail Moun ting ...

  • RuggedCom RS910L - page 9

    9  2007 RuggedCo m Inc. All rights re served Rev100 2.2 Power Supp ly Wiring and Grou nding 2.2.1 A C Power Suppl y Wiring and Gro unding Figure 4 - RS910L Power Supply In puts The RS910L AC power supply inputs should be connected as follows: 1. +/L should be connected to AC Line/Hot. 2. -/N should be connected to AC Neutral. 3. Surge Ground sho ...

  • RuggedCom RS910L - page 10

    10  2007 RuggedCo m Inc. All rights re served Rev100 2.2.2 DC Power Suppl y Wiring and Groundi ng Figure 5 - DC Power sup ply wiring and grounding diagram The RS910L low voltage DC power supply features reverse po larity protection and dual independent inputs. The latter feature allows the connection of two DC sources with the same nominal volta ...

  • RuggedCom RS910L - page 11

    11  2007 RuggedCo m Inc. All rights re served Rev100 2.2.3 Dielectric Strength Testing Units which are to have dielectric strength testing (HIPOT testing) done in the field must have the braided ground cable disconnected during the test. This is required in order to prevent the surge suppression circuitry, which is connected to surge ground, fro ...

  • RuggedCom RS910L - page 12

    12  2007 RuggedCo m Inc. All rights re served Rev100 2.3 Failsafe Output W iring The Failsafe output relay is provided to signal critical error cond itions that may occur on the RS910L. The contacts are energized upon power up of the unit and remain energized until an alarm condition or power loss occurs. The behavior of the failsafe relay is co ...

  • RuggedCom RS910L - page 13

    13  2007 RuggedCo m Inc. All rights re served Rev100 2.4 RS232 Conso le Port Wiring The RS232 port is used for configuring the RS910L. A straight-through serial cable with a DB-9 connector is required. There is no need to crossover the TxD and RxD signals from the PC side since this has been done internally as is shown in the figure below. P i n ...

  • RuggedCom RS910L - page 14

    14  2007 RuggedCo m Inc. All rights re served Rev100 3 Serial Port s The RS910L can be equipped with a Fiber Serial Interface, RS232/RS485/RS422 DB9 serial ports or RS232/RS485/RS422 RJ45 serial ports. 3.1.1 Fiber Serial Interfa ce The RS910L can be equipped with a Fiber Serial Interface (ST connector only) which allows RS485, RS422, or RS232 de ...

  • RuggedCom RS910L - page 15

    15  2007 RuggedCo m Inc. All rights re served Rev100 Pi n R S23 2 Mode R S48 5 Mode R S42 2 Mode 1 C D - - 2 T X T X / R X + ( A) T X + 3 R X - R X + 4 D T R - - 5 6 D SR - RX - 7 C T S T X / R X - (B) T X - 8 R T S - 9 R I (N C) - - Shie l d C o m mo n ( I s o lat e d Gr o un d ) C ha s s is Gr o un d Figure 10: DB9 Port p in-out NOTE: Pins 1, ...

  • RuggedCom RS910L - page 16

    16  2007 RuggedCo m Inc. All rights re served Rev100 Pi n R S232 Mode R S48 5 Mode R S42 2 Mode 1 D SR - RX - 2 D C D - - 3 D T R - - 4 5 R X - R X + 6 T X T X /RX + (A) T X + 7 C T S - - 8 R T S T X / R X - (B) T X - Shie l d C o m mo n ( I s o lat e d Gr o un d ) C ha s s is Gr o un d Figure 11: RJ45 Port pin-out NOTE: Pins 1, 2, and 3 are con ...

  • RuggedCom RS910L - page 17

    17  2007 RuggedCo m Inc. All rights re served Rev100 Figure 12: Co nceptual reco mmended RS485 wiring d iagram 3.1.5 Serial Port Transie nt Protection RuggedCom does not recommend the use of copper cabling of any length for critical real-time substation automation applications. However, transient suppre ssion circuitry is present on all copper p ...

  • RuggedCom RS910L - page 18

    18  2007 RuggedCo m Inc. All rights re served Rev100 4 Ethernet Port s 4.1 RJ11 Ethernet ove r VDSL Port 4.1.1 Overview The Ethernet over VDSL (EoVDSL) port on RS910L operates in pairs with one configured as the Master and the other as the Slave. In VDSL literature the terms Central Office (CO) or Line Termination (LT) are used interchangeably f ...

  • RuggedCom RS910L - page 19

    19  2007 RuggedCo m Inc. All rights re served Rev100 4.1.2 Wiring VDSL typically operates over 2-wire CAT-3 wiring; however, other categorized or uncategorized twisted-pair wiring will work although the performance will vary dep ending on the distance and cable characteristics. It is important that the wiring used does not have any open leads (a ...

  • RuggedCom RS910L - page 20

    20  2007 RuggedCo m Inc. All rights re served Rev100 The unit can automatically select the best bit-rate based on current line conditions. If the line conditions degrade (reducing the SNR) but the unit is able to maintain the link, an alarm will be triggered to notify the user of the reduced SNR. If the line conditions degrade such that the unit ...

  • RuggedCom RS910L - page 21

    21  2007 RuggedCo m Inc. All rights re served Rev100 Table 5 - RJ4 5 Ethernet port p in-out NOTE: RuggedCom does not recommend the use of CAT-5 (10/100Base-TX communications) cabling of any length for critical real-time substation automation applications. However, transient suppression circuitry is present on all copper ports to protect against ...

  • RuggedCom RS910L - page 22

    22  2007 RuggedCo m Inc. All rights re served Rev100 Figure 18: 10 0FX LC connect or Figure 19: 10 0FX SC connector 4.4 Ethernet Panel Description Each Ethernet and Serial port is equipped with one LED that indicates link/activity status information. The LED will be solid for ports with link, and will blink for activity. The diagram in Figure 20 ...

  • RuggedCom RS910L - page 23

    23  2007 RuggedCo m Inc. All rights re served Rev100 5 T echnical Specifications 5.1 Operating Envi ronment Parameter Range Comment s Ambient Operating Tem perature -40 to 85 ° C Ambient Temperatu re as measured from a 30 cm radius surrounding the ce nter of the RS910 enclosure. Ambient Storage Tempe rature -40 to 85 ° C Ambient Relative Humid ...

  • RuggedCom RS910L - page 24

    24  2007 RuggedCo m Inc. All rights re served Rev100 5.4 RJ11 Ethernet ove r VDSL Port Spec ifications Data Port Media Distance Connecto r Type VDSL CAT-3 UTP or STP 2500m RJ11 Table 9 – RJ1 Eth ernet over VDSL Port Specification s 5.5 Serial Ports 5.5.1 Copper Ports Parameter Specifications Notes Baud Rate 300 bps – 230 kbps Connector DB9 o ...

  • RuggedCom RS910L - page 25

    25  2007 RuggedCo m Inc. All rights re served Rev100 5.6 Ethernet Ports 5.6.1 Copper Ports Parameter Specification Notes Speed 10/100 Mbps Auto-negotiating Duplex FDX / HDX Auto-negotiating Cable-Type > Category 5 Shielded/Unshielded Wiring Standard TIA/EIA T568A/B Auto-Crossover, Auto-polarity Max Distance 100 m Connector RJ45 Isolation 1.5 ...

  • RuggedCom RS910L - page 26

    26  2007 RuggedCo m Inc. All rights re served Rev100 5.8 Mechanical Specif ications Figure 21 - M echanical Specif ications Table 15 - M echanical Speci fications Parameter Value Dimensions 16.8 x 11.7 x 6.6 cm / 6.6 x 4.6 x 2.6 inches Weight 1.2 kg / 2.7 lbs Enclosure 20 AWG Galvanized Steel ...

  • RuggedCom RS910L - page 27

    27  2007 RuggedCo m Inc. All rights re served Rev100 6 T ype T est s 6.1 IEC 61850-3 Type Tests Test Description Test Levels Severity Levels Enclosure Contact +/- 8kV 4 IEC 61000-4-2 ESD Enclosure Air +/- 15kV 4 IEC 61000-4-3 Rad iated RFI Enclosure por ts 20 V/m x Signal ports +/- 4kV @ 2.5kHz x D.C. Power ports +/- 4 kV 4 A.C. Power ports +/- ...

  • RuggedCom RS910L - page 28

    28  2007 RuggedCo m Inc. All rights re served Rev100 6.2 IEEE 1613 Type T ests Test Description Test Levels Enclosure Contact +/- 8kV IEEE C37.90.3 ESD Enclosure Air +/- 15kV IEEE C37.90.2 Ra diated RFI Enclosure ports 35 V/m Signal ports +/- 4kV @ 2.5kHz D.C. Power ports +/- 4kV A.C. Power ports +/- 4kV IEEE C37.90.1 Fast Transient Earth ground ...

  • RuggedCom RS910L - page 29

    29  2007 RuggedCo m Inc. All rights re served Rev100 7 W arrant y RuggedCom warrants this product for a period of five (5) years from date of purchase. For warranty details, visit http://www.ruggedcom.com or contact your customer service representative. Should this product require warranty or service contact the factory at: RuggedCom Inc. 30 Whi ...

Fabbricante RuggedCom Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoRuggedCom RS910L possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici RuggedCom
- manuali per l’uso RS910L
- schede prodotto RuggedCom
- opuscoli
- o etichette energetiche RuggedCom RS910L
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso RuggedCom RS910L.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione RuggedCom RS910L, manuali di manutenzione, brevi manuali o manuali utente RuggedCom RS910L. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto RuggedCom RS910L.

Manuali per l’uso simili

Manuale completo del dispositivo RuggedCom RS910L, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare RuggedCom RS910L dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti RuggedCom RS910L.

Il manuale per l’uso completo RuggedCom, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale RuggedCom RS910L - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice RuggedCom RS910L, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per RuggedCom RS910L che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo RuggedCom RS910L - che ci dovrebbe aiutare nei primi passi durante l'uso RuggedCom RS910L
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del RuggedCom RS910L
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio RuggedCom RS910L in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su RuggedCom RS910L?

Utilizza il modulo sottostante

Se non hai risolto il problema con RuggedCom RS910L con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con RuggedCom RS910L è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)