  • Eaton Electrical -66103 - page 1

    www.eaton. com Network Managemen t Card & Modbus/ Jbus (661 03) Installation manual 34003906EN_AE.fm Page 1 Vendredi, 19. décembre 2008 1:49 13 ...

  • Eaton Electrical -66103 - page 2

    2 - 34003906E N/AE 34003906EN_AE.fm Page 2 Vendredi, 19. décembre 2008 1:49 13 ...

  • Eaton Electrical -66103 - page 3

    34003906E N/AE - 3 The Net work M anagem ent Car d & Modbus /Jb us (66103) is recommended for central UPSs protec ting entir e networ ks or for UPS uni ts backi ng up critic al loa ds. With the card ins talled , the UPS has its own IP address and us es the loc al computer capabil ities to : ● Supply web pages (http or https (SSL )) with infor ...

  • Eaton Electrical -66103 - page 4

    4 - 34003906E N/AE . ETHERNET po rt Service port (Settings/ Sensor) O VERVIEW INDICA TIONS LED Colour Status Des cripti on ACT Green ● OFF ● ON ● Flas hing ● Card no t conne cted to ne twor k ● Card conn ecte d to netw ork, bu t no act ivit y ● Port is sending/re ceiving 100M Orang e ● OFF ● ON ● Port operating at 10 Mb its/s ● ...

  • Eaton Electrical -66103 - page 5

    34003906E N/AE - 5 The Net work M anagem ent Car d & Modbus /Jb us (66103) can be hot-plugged on all UPSs fro m EATON equi pped wit h a Mi nislot . It i s not necessa ry to s hutdown the UPS, disco nnect t he load or re start the U PS. ● Remove the plastic co ver of the Minislot. ● Note the MAC address of the card bef ore insertin g it. ● ...

  • Eaton Electrical -66103 - page 6

    6 - 34003906E N/AE The card i s confi gured by def ault w ith this s ervice enabled. No manual c onfigura tion i s requir ed.The IP parameters are auto matically collected by the card. From the main configuration menu: (see above) ● Press the 2 key (Network configuration). ● Press the 1 key(Read Network settings). The settings sup plied by the ...

  • Eaton Electrical -66103 - page 7

    34003906E N/AE - 7 To check whe ther th e Network Management Card & Modb us/J bus (66103) is oper ational after installation and con figuration, pr oceed as follows. ● Run a brow ser ● Enter in the address bar: http:/ /I P addr ess/ (e.g. http://172.16.1.82/) ● The home page is displ ayed ● Set the t ime by c licking the Time comma nd. ...

  • Eaton Electrical -66103 - page 8

    8 - 34003906E N/AE The Envir onment sen sor is a N etwor k Manage ment Car d & Modb us/Jbu s option. It is available from EA TON (cat. no 66846) . The sensor remotely monito rs the UPS environment by regularly measuring the temperature and humidity, and checking the states of t wo external c ontacts. It can also send alarms (e-mail, S NMP trap ...

  • Eaton Electrical -66103 - page 9

    34003906E N/AE - 9 RS232 link con figuration and connecti on RS485 link con figuration and connecti on For prop er operation, th e polarity of EIA RS485 2-wire an d 4-wire lin es must be s et at only one po int and the lines terminated at the end. Polarity Normally, th e master of the netw ork sets th e polarity of th e line. The rec eiver inputs h ...

  • Eaton Electrical -66103 - page 10

    10 - 34003906E N/AE 2 wires con nection Card sett ings of an intermediate cubicle Ot hers sett ings SA1 SA2 SA1 OFF ON 1 8 SA2 OFF ON 1 8 SA2 SA2 SA2 SA1 SA1 SA1 5 L + 43 2 1 L - 5V Rp Ra Rp 0V Ra 0V Ra 0V L- L- L+ L+ L- L- L+ L+ 3 7 24 13 24 13 polarity connection if end of the line polarity transmit/receive data transmit/receive data transmit/rec ...

  • Eaton Electrical -66103 - page 11

    34003906EN/A E - 11 4 wires con nection Card sett ings of an intermediate cubicle Others set tings SA1 SA2 5 R- 43 2 1 R + T - T + SA1 OFF ON 1 8 SA2 OFF ON 1 8 SA2 SA2 SA2 SA1 SA1 SA1 5V Rp Rp 0V Ra Ra T- R - T+ R+ R- R- R+ R+ 2 1 2 1 5V Rp Ra Rp 0V R- T - R+ T+ T- T- T+ T+ 4 3 4 3 master transmitt slav e receiver slav e receiver termination termi ...

  • Eaton Electrical -66103 - page 12

    12 - 34003906E N/AE Configuration of the JBUS/MO DBUS communicati on p arameters ● Use t he cord supp lied wit h the card ● Co nnect the card to a co mputer ● Us e a terminal emu lator such as HyperTerminal TM with these setting s "Echo type d charact ers loca lly" opt ion: disa bled ● Check that UPS power is on. ● Type EATON (o ...

  • Eaton Electrical -66103 - page 13

    34003906EN/A E - 13 ● Press the 2 key (Modifiy Jbus settings) ● Press «Return» key to modify t he Jbus settings * Hex f orma t. ● Press the 0 key (Exit). ● Press the 0 key (Exit). ● Run a brow ser ● Enter in the address bar: http:/ /I P addr ess/ (e.g. http://172.16.1.82/) ● The home page is displ ayed ● S elec t the set ting me n ...

  • Eaton Electrical -66103 - page 14

    14 - 34003906E N/AE TECHNICAL CHARACTERISTICS Physic al charac teristi cs Dimensi ons (W x D x H) 132 x 66 x 42 mm Weight 70 g RoHS 100% compatible Storage Storag e tempe rature r ange -10°C t o 70°C Ambie nt cond itions Operat ing tem perat ure rang e 0°C to 40°C Relativ e hum idity 90% R H max. wi thou t conde nsation Card perfo rmanc e Suppl ...

  • Eaton Electrical -66103 - page 15

    34003906EN/A E - 15 When co rrectly installed a nd used in accordance with manufactu rer instructions, the card complies with the fol lowin g standar ds: ● ITE ( Informatio n Technology Equipment) safety: IEC/EN 60950-1 2002 ● EMC: EN 61000-6-2 (2002), EN 61000-6-3 (2002), IEC/EN 62040-2 (2002) In complian ce with E uropean directives: ● Low ...

  • Eaton Electrical -66103 - page 16

    34003906EN/A E www.e aton .com 34003906EN_AE.fm Page 16 Vendredi, 19. décembre 2008 1:49 1 3 ...

Fabbricante Eaton Electrical Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoEaton Electrical -66103 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Eaton Electrical
- manuali per l’uso -66103
- schede prodotto Eaton Electrical
- opuscoli
- o etichette energetiche Eaton Electrical -66103
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Eaton Electrical -66103.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Eaton Electrical -66103, manuali di manutenzione, brevi manuali o manuali utente Eaton Electrical -66103. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Eaton Electrical -66103.

Manuale completo del dispositivo Eaton Electrical -66103, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Eaton Electrical -66103 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Eaton Electrical -66103.

Il manuale per l’uso completo Eaton Electrical, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Eaton Electrical -66103 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Eaton Electrical -66103, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Eaton Electrical -66103 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Eaton Electrical -66103 - che ci dovrebbe aiutare nei primi passi durante l'uso Eaton Electrical -66103
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Eaton Electrical -66103
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Eaton Electrical -66103 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Eaton Electrical -66103?

Utilizza il modulo sottostante

Se non hai risolto il problema con Eaton Electrical -66103 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Eaton Electrical -66103 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)