Manuale per l’uso Omega Engineering CCT-55-I

18 pagine 0.14 mb
Scarica

Vai alla pagina of 18

Summary
  • Omega Engineering CCT-55-I - page 1

    http://www.omega.com e-mail: info@omega.com ® U ser ’ s Guide CCT -55/ CCT -55-I Signal Integrators M2304/1201 ...

  • Omega Engineering CCT-55-I - page 2

    Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com For immediate technical or application assistance: USA and Canada: Sales Service: ...

  • Omega Engineering CCT-55-I - page 3

    T ABLE OF CONTENTS PAGE Open the Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Internal Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Power Supply module MA . . . . . . . . . . . . . . . . . . . . . . 4 Changing the Power Supply . . . . . . . . . . . . . . . . . . . . 4 Signal Output, module MS-55 Overview . ...

  • Omega Engineering CCT-55-I - page 4

    PROCEDURE 1. Insert a screwdriver or similar tool in the points marked c . 2. Turn the screwdriver until the case walls begin to separate towards A and B , so the two side lugs e , are free. 3. Grab the Signal Conditioner body, at the points marked d ‚ and pull it towards C , until the two side lugs e are out of their housing and the internal cir ...

  • Omega Engineering CCT-55-I - page 5

    FIG.11 + - - + POWER SUPPLY The side label, shows the type and value of the power supply. OUTPUTS / SALIDAS mA Vdc INPUT / ENTRADA SUPPLY / A LI MENTA CI O N 3 4 5 6 9 10 11 12 7 1 + Lo H i + -- The voltage excitation for the current loop, it is supplied by the signal conditioner (24 Vdc @ 25 mA). Terminals 3 and 5, for 2-wire transducers. Terminal ...

  • Omega Engineering CCT-55-I - page 6

    A B C D A INPUT Close jumpers on module : RANGE MP ME "MP" Input board Components view SIGNAL INPUT RANGE SELECTION Set the jumper to the position indicated in the table below for each range. The jumpers are located on the "MP" input board and "ME" input module. See Fig. 9. If the signal input range is modified, follow ...

  • Omega Engineering CCT-55-I - page 7

    CCT-55-I : DC CURRENT INTEGRATOR ELECTRICAL FEATURES SIGNAL INPUT OUTPUT FREQUENCY : Pulses per second 0 to 10,000 (12 selectable ranges). Pulses per hour 0 to 8,790 (13 selectable ranges). TYPE OF PULSES: V oltag e 24 Vdc @ 20 mA maximum. Sink Current 100 mA. (24 Vdc external power supply) PULSE WIDTH 100 mS; 50 % of the full cycle or variable wit ...

  • Omega Engineering CCT-55-I - page 8

    SIGNAL INPUT RANGE SELECTION Set the jumpers to the position indicated in Table 5 for each range. The jumpers are located on the "MP" input board. See Fig. 8. If the signal input range is modified, follow the adjustment and calibration procedure. FREQUENCY OUTPUT RANGE SELECTION PULSES PER HOUR Table 3 indicates all the standard available ...

  • Omega Engineering CCT-55-I - page 9

    CCT-55-V; DC VOLTAGE INTEGRATOR ELECTRICAL FEATURES INPUT OUTPUT FREQUENCY : Pulses per second 0 to 10,000 (12 selectable ranges) Pulses per hour 0 to 8,790 (13 selectable ranges) TYPE OF PULSES : V oltag e 24 Vdc @ 20 mA maximum Sink Current 100 mA. (24 Vdc external power supply) PULSE WIDTH 100 ms; 50 % of the full cycle or variable with frequenc ...

  • Omega Engineering CCT-55-I - page 10

    CCT-55-V; DC VOLTAGE INTEGRATOR ELECTRICAL FEATURES INPUT OUTPUT FREQUENCY : Pulses per second 0 to 10,000 (12 selectable ranges) Pulses per hour 0 to 8,790 (13 selectable ranges) TYPE OF PULSES : V oltag e 24 Vdc @ 20 mA maximum Sink Current 100 mA. (24 Vdc external power supply) PULSE WIDTH 100 ms; 50 % of the full cycle or variable with frequenc ...

  • Omega Engineering CCT-55-I - page 11

    SIGNAL INPUT RANGE SELECTION Set the jumpers to the position indicated in Table 5 for each range. The jumpers are located on the "MP" input board. See Fig. 8. If the signal input range is modified, follow the adjustment and calibration procedure. FREQUENCY OUTPUT RANGE SELECTION PULSES PER HOUR Table 3 indicates all the standard available ...

  • Omega Engineering CCT-55-I - page 12

    CCT-55-I : DC CURRENT INTEGRATOR ELECTRICAL FEATURES SIGNAL INPUT OUTPUT FREQUENCY : Pulses per second 0 to 10,000 (12 selectable ranges). Pulses per hour 0 to 8,790 (13 selectable ranges). TYPE OF PULSES: V oltag e 24 Vdc @ 20 mA maximum. Sink Current 100 mA. (24 Vdc external power supply) PULSE WIDTH 100 mS; 50 % of the full cycle or variable wit ...

  • Omega Engineering CCT-55-I - page 13

    A B C D A INPUT Close jumpers on module : RANGE MP ME "MP" Input board Components view SIGNAL INPUT RANGE SELECTION Set the jumper to the position indicated in the table below for each range. The jumpers are located on the "MP" input board and "ME" input module. See Fig. 9. If the signal input range is modified, follow ...

  • Omega Engineering CCT-55-I - page 14

    FIG.11 + - - + POWER SUPPLY The side label, shows the type and value of the power supply. OUTPUTS / SALIDAS mA Vdc INPUT / ENTRADA SUPPLY / A LI MENTA CI O N 3 4 5 6 9 10 11 12 7 1 + Lo H i + -- The voltage excitation for the current loop, it is supplied by the signal conditioner (24 Vdc @ 25 mA). Terminals 3 and 5, for 2-wire transducers. Terminal ...

  • Omega Engineering CCT-55-I - page 15

    PROCEDURE 1. Insert a screwdriver or similar tool in the points marked c . 2. Turn the screwdriver until the case walls begin to separate towards A and B , so the two side lugs e , are free. 3. Grab the Signal Conditioner body, at the points marked d ‚ and pull it towards C , until the two side lugs e are out of their housing and the internal cir ...

  • Omega Engineering CCT-55-I - page 16

    T ABLE OF CONTENTS PAGE Open the Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Internal Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Power Supply module MA . . . . . . . . . . . . . . . . . . . . . . 4 Changing the Power Supply . . . . . . . . . . . . . . . . . . . . 4 Signal Output, module MS-55 Overview . ...

  • Omega Engineering CCT-55-I - page 17

    WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers recei ...

  • Omega Engineering CCT-55-I - page 18

    Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers & Process Monitors M U Infrared Pyrometers PRE ...

Fabbricante Omega Engineering Categoria Stereo System

I documenti che otteniamo dal fabbricante del dispositivoOmega Engineering CCT-55-I possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Omega Engineering
- manuali per l’uso CCT-55-I
- schede prodotto Omega Engineering
- opuscoli
- o etichette energetiche Omega Engineering CCT-55-I
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Omega Engineering CCT-55-I.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Omega Engineering CCT-55-I, manuali di manutenzione, brevi manuali o manuali utente Omega Engineering CCT-55-I. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Omega Engineering CCT-55-I.

Manuale completo del dispositivo Omega Engineering CCT-55-I, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Omega Engineering CCT-55-I dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Omega Engineering CCT-55-I.

Il manuale per l’uso completo Omega Engineering, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Omega Engineering CCT-55-I - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Omega Engineering CCT-55-I, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Omega Engineering CCT-55-I che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Omega Engineering CCT-55-I - che ci dovrebbe aiutare nei primi passi durante l'uso Omega Engineering CCT-55-I
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Omega Engineering CCT-55-I
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Omega Engineering CCT-55-I in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Omega Engineering CCT-55-I?

Utilizza il modulo sottostante

Se non hai risolto il problema con Omega Engineering CCT-55-I con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Omega Engineering CCT-55-I è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)